Assessment of the usefulness of the standardized uptake values and the radioactivity levels for the preoperative diagnosis of thyroid cancer measured by using 18F-FDG PET/CT dual-time-point imaging

被引:1
|
作者
Lee, Hyeon-Guck [1 ]
Hong, Seong-Jong [1 ]
Cho, Jae-Hwan [2 ]
Han, Man-Seok [3 ]
Kim, Tae-Hyung [3 ]
Lee, Ik-Han [4 ]
机构
[1] Eulji Univ, Grad Sch, Dept Publ Hlth, Taejon 301746, South Korea
[2] Hallym Univ Grad Studies, Dept Int Radiol Sci, Seoul 135841, South Korea
[3] Kangwon Natl Univ, Dept Radiol Sci, Samchuk 245905, South Korea
[4] Kyongbuk Sci Uunivers, Dept Optometry, Chilgok 718851, South Korea
关键词
F-18-FDG PET/CT; Dual-time-point imaging; MaxSUV; Radioactivity levels; POSITRON-EMISSION-TOMOGRAPHY; DIFFERENTIATION; ACCUMULATION; CARCINOMA; LESIONS; BENIGN;
D O I
10.3938/jkps.62.677
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The purpose of this study was to assess and compare the changes in the SUV (standardized uptake value), the F-18-FDG (F-18-fluorodeoxyglucose) uptake pattern, and the radioactivity level for the diagnosis of thyroid cancer via dual-time-point F-18-FDG PET/CT (positron emission tomographycomputed tomography) imaging. Moreover, the study aimed to verify the usefulness and significance of SUV values and radioactivity levels to discriminate tumor malignancy. A retrospective analysis was performed on 40 patients who received F-18-FDG PET/CT for thyroid cancer as a primary tumor. To set the background, we compared changes in values by calculating the dispersion of scattered rays in the neck area and the lung apex, and by comparing the mean and SD (standard deviation) values of the maxSUV and the radioactivity levels. According to the statistical analysis of the changes in F-18-FDG uptake for the diagnosis of thyroid cancer, a high similarity was observed with the coefficient of determination being R-2 = 0.939, in the SUVs and the radioactivity levels. Moreover, similar results were observed in the assessment of tumor malignancy using dual-time-point. The quantitative analysis method for assessing tumor malignancy using radioactivity levels was neither specific nor discriminative compared to the semi-quantitative analysis method.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 50 条
  • [1] Assessment of the usefulness of the standardized uptake values and the radioactivity levels for the preoperative diagnosis of thyroid cancer measured by using 18F-FDG PET/CT dual-time-point imaging
    Hyeon-Guck Lee
    Seong-Jong Hong
    Jae-Hwan Cho
    Man-Seok Han
    Tae-Hyung Kim
    Ik-Han Lee
    Journal of the Korean Physical Society, 2013, 62 : 677 - 683
  • [2] The Clinical Role of Dual-Time-Point 18F-FDG PET/CT in Differential Diagnosis of the Thyroid Incidentaloma
    Lee S.
    Park T.
    Park S.
    Pahk K.
    Rhee S.
    Cho J.
    Jeong E.
    Kim S.
    Choe J.G.
    Nuclear Medicine and Molecular Imaging, 2014, 48 (2) : 121 - 129
  • [3] Potential of dual-time-point imaging to improve breast cancer diagnosis with 18F-FDG PET
    Kumar, R
    Loving, VA
    Chauhan, A
    Zhuang, HMM
    Mitchell, S
    Alavi, A
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (11) : 1819 - 1824
  • [4] Hepatoid adenocarcinoma of the stomach: dual-time-point 18F-FDG PET/CT findings
    Sun, Xiaorong
    Li, Yuhui
    Dong, Min
    Li, Wenwu
    Xing, Ligang
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (12) : 721 - 724
  • [5] The added value of dual-time-point 18F-FDG PET/CT imaging in the diagnosis of colorectal cancer liver metastases
    Wujian Mao
    Jun Zhou
    Lin Qiu
    Hongyan Yin
    Hui Tan
    Hongcheng Shi
    Abdominal Radiology, 2020, 45 : 1075 - 1081
  • [6] Dual-time-point 18F-FDG-PET/CT imaging in the assessment of suspected malignancy
    Chan, Wai-Ling
    Ramsay, Stuart C.
    Szeto, Edwin R.
    Freund, Judith
    Pohlen, Judith M.
    Tarlinton, Lisa C.
    Young, Andy
    Hickey, Adam
    Dura, Robert
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (04) : 379 - 390
  • [7] Dual-time-point 18F-FDG PET/CT in patients with colorectal cancer: clinical value of early delayed scanning
    Miyake, Kanae K.
    Nakamoto, Yuji
    Togashi, Kaori
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (06) : 492 - 500
  • [8] The added value of dual-time-point 18F-FDG PET/CT imaging in the diagnosis of colorectal cancer liver metastases
    Mao, Wujian
    Zhou, Jun
    Qiu, Lin
    Yin, Hongyan
    Tan, Hui
    Shi, Hongcheng
    ABDOMINAL RADIOLOGY, 2020, 45 (04) : 1075 - 1081
  • [9] Brown fat uptake of 18F-FDG on dual time point PET/CT imaging
    Rashmizal, Hairil A. R.
    Noraini, A. R.
    Rossetti, C.
    Jalil, Abdul N.
    SINGAPORE MEDICAL JOURNAL, 2010, 51 (02) : E37 - E39
  • [10] Potential performance of dual-time-point 18F-FDG PET/CT compared with single-time-point imaging for differential diagnosis of metastatic lymph nodes: a meta-analysis
    Shen, Guohua
    Deng, Houfu
    Hu, Shuang
    Jia, Zhiyun
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (10) : 1003 - 1010