Desalination using membrane distillation: Flux enhancement by feed water deaeration on spiral-wound modules

被引:68
作者
Winter, D. [2 ]
Koschikowski, J. [2 ]
Ripperger, S. [1 ]
机构
[1] Tech Univ Kaiserslautern, Lehrstuhl Mech Verfahrenstech, D-67663 Kaiserslautern, Germany
[2] Fraunhofer Inst Solar Energy Syst ISE, D-79110 Freiburg, Germany
关键词
Desalination; Membrane distillation; Spiral-wound module; Deaeration; MASS-TRANSFER; HEAT; GAS;
D O I
10.1016/j.memsci.2012.08.018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane distillation (MD) is considered a promising technology for desalination applications. In this paper, the main transport phenomena in membrane distillation are analyzed theoretically. One of the main limiting factors is the molecular diffusion resistance caused by stagnant air in the membrane pore volume. A great potential for flux enhancement has been identified to be the removal of air in the membrane pores. Preliminary experiments on water deaeration using a commercial membrane contactor were carried out. The dynamics of membrane and air gap deaeration using deaerated feed water were studied experimentally. A module test facility was equipped with a feed water deaeration setup. Full-scale spiral-wound modules with a membrane area of 5 and 10 m(2) have been used for comprehensive experimental studies on the use of deaerated feed water. The impact of deaeration at different pressures, feed flow rates, feed water salinities and temperature levels is quantified and discussed. A comparison of module operation with and without preceding feed water deaeration is given. The experimental results include module output rate, thermal energy demand, thermal efficiency and an estimation of the electrical energy demand. In all experiments, the beneficial effect of feed water deaeration can clearly be shown for total flux and thermal energy demand simultaneously. For selected operation points, the relative effect was identified to be more than 5000 and the specific thermal energy demand dropped to values of less than 100 kW(th) m(-3). (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 21 条
[1]   Heat and mass transfer resistance analysis of membrane distillation [J].
Alklaibi, A. M. ;
Lior, Noam .
JOURNAL OF MEMBRANE SCIENCE, 2006, 282 (1-2) :362-369
[2]  
[Anonymous], 2018, Physical Chemistry
[3]   Performance evaluation of the "large SMADES" autonomous desalination solar-driven membrane distillation plant in Aqaba, Jordan [J].
Banat, Fawzi ;
Jwaied, Nesreen ;
Rommel, Matthias ;
Koschikowski, Joachim ;
Wieghaus, Marcel .
DESALINATION, 2007, 217 (1-3) :17-28
[4]   CFD simulation of a membrane distillation module channel [J].
Cipollina, A. ;
Di Miceli, A. ;
Koschikowski, J. ;
Micale, G. ;
Rizzuti, L. .
DESALINATION AND WATER TREATMENT, 2009, 6 (1-3) :177-183
[5]   Operational experience of a solar membrane distillation demonstration plant in Pozo Izquierdo-Gran Canaria Island (Spain) [J].
Gemma Raluy, R. ;
Schwantes, Rebecca ;
Subiela, Vicente J. ;
Penate, Baltasar ;
Melian, Gustavo ;
Rosa Betancort, Juana .
DESALINATION, 2012, 290 :1-13
[6]  
Gesellschaft Verfahrenstechnik und Chemieingenieurwesen, 2006, VDI WARMEATLAS BEREC
[7]  
GmbH I.E., CAT D 0060 05
[8]   Air gap membrane distillation - 2. Model validation and hollow fibre module performance analysis [J].
Guijt, CM ;
Meindersma, GW ;
Reith, T ;
de Haan, AB .
SEPARATION AND PURIFICATION TECHNOLOGY, 2005, 43 (03) :245-255
[9]  
Homig H.E., 1978, SEAWATER AND SEAWATE
[10]  
Jousten K., 2010, WUTZ HANDBUCH VAKUUM