共 32 条
Development of a low-density polyethylene-containing passive sampler for measuring dissolved hydrophobic organic compounds in open waters
被引:39
作者:
Bao, Lian-Jun
[1
,2
]
Xu, Shi-Ping
[1
]
Liang, Yan
[3
]
Zeng, Eddy Y.
[1
]
机构:
[1] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou, Guangdong, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing, Peoples R China
[3] Hong Kong Baptist Univ, Dept Biol, Hong Kong, Hong Kong, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Low-density polyethylene;
Passive sampling;
Hydrophobic organic compound;
Open water;
Field validation;
SEMIPERMEABLE-MEMBRANE DEVICES;
SOLID-PHASE MICROEXTRACTION;
PEARL RIVER DELTA;
ORGANOCHLORINE PESTICIDES;
AROMATIC-HYDROCARBONS;
UPTAKE RATES;
DEGRADATION;
SORPTION;
RUNOFF;
CHINA;
D O I:
10.1002/etc.1788
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
A passive water sampler with low-density polyethylene (LDPE) as the sorbent phase was built and field-tested for sensing freely dissolved concentrations of hydrophobic organic compounds (HOCs) in fresh and coastal water. Based on the measured LDPEwater partition coefficients (Kpew) of 12 polycyclic aromatic hydrocarbons (PAHs) and dichlorodiphenyltrichloroethane (DDT) and its seven metabolites, the detection limits with the passive sampler containing 10-g LDPE ranged from 0.04 to 56.9?pg/L in the equilibrium sampling mode. Furthermore, the utility of the passive sampler in measuring dissolved HOC concentrations in open waters was examined through a comparison with solid-phase extraction combined with liquidliquid extraction (SPE-LLE) and poly(dimethyl)siloxane (PDMS) coated fiber samplers. The total concentrations of PAHs (3.816?ng/L) obtained by the passive sampler were lower than those (87.7115.5?ng/L) obtained through SPE-LLE. This large difference was probably attributable to slower water exchange in and out of the passive sampler as time progressed because of blockage by algae in eutrophia reservoirs and high dissolved organic carbon contents resulting in higher-than-expected PAH concentrations by SPE-LLE. Furthermore, the concentrations and compositional profiles of DDXs (sum of p,p'-DDT, p,p'-DDD, p,p'-DDE, o,p'-DDT, o,p'-DDD, o,p'-DDE, and p,p'-DDMU) at site A obtained by the passive sampler agreed with the results obtained with the PDMS-coated fibers, suggesting that the passive sampler was able to reasonably quantify dissolved HOCs in seawater. Environ. Toxicol. Chem. 2012; 31: 10121018. (c) 2012 SETAC
引用
收藏
页码:1012 / 1018
页数:7
相关论文