Simultaneous label-free and pretreatment-free detection of heavy metal ions in complex samples using electrodes decorated with vertically-ordered silica nanochannels

被引:101
作者
Cheng, Bowen [1 ]
Zhou, Lin [1 ]
Lu, Lili [1 ]
Liu, Jiyang [1 ]
Dong, Xiaoping [1 ]
Xi, Fengna [1 ]
Chen, Peng [2 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Xiasha Higher Educ Zone, 5 Second Ave, Hangzhou 310018, Zhejiang, Peoples R China
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, 70 Nanyang Dr, Singapore 637457, Singapore
基金
中国国家自然科学基金;
关键词
Electrochemical sensing; Vertically-ordered silica nanochannels; Detection of heavy metal ions; SIMULTANEOUS ELECTROCHEMICAL DETECTION; FUNCTIONALIZED MESOPOROUS SILICA; SELECTIVE DETECTION; ORGANOSILICA FILMS; WATER SAMPLES; LEAD; PB2+; MESOCHANNELS; FABRICATION; MEMBRANES;
D O I
10.1016/j.snb.2017.12.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, indium tin oxide coated glass (ITO) decorated with vertically-ordered mesoporous silica film (VMSF/ITO) is synthesized and applied as electrochemical sensor for simultaneous label-free and pretreatment-free detection of Pb2+, Cu2+, and Cd2+ in human serum and soil leaching solution. Using differential pulse voltammetry (DPV), the electrochemical detection consists of electro-deposition of metal species and subsequent anodic stripping in the silica nanochannels. Because of the electrostatic enrichment and nano-confinement effects, VMSF/ITO is able to simultaneously detect Pb2+, Cu2+, and Cd2+ in a mixture with low detection limits (2.6 nM, 32 nM and 230 nM, respectively). Moreover, VMSF confer the electrode with excellent anti-fouling and anti-interference property through steric exclusion and electrostatic repulsion. Direct analysis of complex biological (human serum) and environmental (soil leaching solution) samples could be finished within 10 min without the usual need of tedious pretreatment. Furthermore, the VMSF/ITO sensor can be reused for several times without performance degradation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:364 / 371
页数:8
相关论文
共 57 条
[1]   A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms [J].
Bansod, BabanKumar ;
Kumar, Tejinder ;
Thakur, Ritula ;
Rana, Shakshi ;
Singh, Inderbir .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :443-455
[2]   One-pot synthesis of sulfur-doped graphene quantum dots as a novel fluorescent probe for highly selective and sensitive detection of lead(II) [J].
Bian, Shiyue ;
Shen, Chao ;
Hua, Hong ;
Zhou, Lin ;
Zhu, Hailin ;
Xi, Fengna ;
Liu, Jiyang ;
Dong, Xiaoping .
RSC ADVANCES, 2016, 6 (74) :69977-69983
[3]   Interpreting and managing blood lead levels of less than 10 μg/dL in children and reducing childhood exposure to lead:: Recommendations of the Centers for Disease Control and Prevention advisory committee on childhood lead poisoning prevention [J].
Binns, Helen J. ;
Campbell, Carla ;
Brown, Mary Jean .
PEDIATRICS, 2007, 120 (05) :E1285-E1298
[4]  
Brainina K. Z., 1993, ELECTRODNALYTICAL ST
[5]   Simultaneous Determination of Cadmium, Lead, Copper and Mercury Ions Using Organofunctionalized SBA-15 Nanostructured Silica Modified Graphite - Polyurethane Composite Electrode [J].
Cesarino, Ivana ;
Cavalheiro, Eder T. G. ;
Brett, Christopher M. A. .
ELECTROANALYSIS, 2010, 22 (01) :61-68
[6]   A disposable chronocoulometric sensor for heavy metal ions using a diaminoterthiophene-modified electrode doped with graphene oxide [J].
Choi, Seung-Min ;
Kim, Dong-Min ;
Jung, Ok-Sang ;
Shim, Yoon-Bo .
ANALYTICA CHIMICA ACTA, 2015, 892 :77-84
[7]   Simultaneous and Selective Detection of Environment Hazardous Metals in Water Samples by Using Flower and Christmas Tree Like Cerium Hexacyanoferrate Modified Electrodes [J].
Devadas, Balamurugan ;
Sivakumar, Mani ;
Chen, Shen-Ming ;
Rajkumar, Muniyandi ;
Hu, Chi-Chang .
ELECTROANALYSIS, 2015, 27 (11) :2629-2636
[8]   Oriented Mesoporous Organosilica Films on Electrode: A New Class of Nanomaterials for Sensing [J].
Etienne, Mathieu ;
Goux, Aurelie ;
Sibottier, Emilie ;
Walcarius, Alain .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (04) :2398-2406
[9]   Rod-like hydroxyapatite and Nafion nanocomposite as an electrochemical matrix for simultaneous and sensitive detection of Hg2+, Cu2+, Pb2+ and Cd2+ [J].
Gao, Feng ;
Gao, Ningning ;
Nishitani, Ayaka ;
Tanaka, Hidekazu .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 775 :212-218
[10]   Simple and Robust Green Synthesis of Au NPs on Reduced Graphene Oxide for the Simultaneous Detection of Toxic Heavy Metal Ions and Bioremediation Using Bacterium as the Scavenger [J].
Gnanaprakasam, Periyasami ;
Jeena, Soban Easow ;
Premnath, Dhanaraj ;
Selvaraju, Thangavelu .
ELECTROANALYSIS, 2016, 28 (08) :1885-1893