Methodology validation, intra-subject reproducibility and stability of exhaled volatile organic compounds

被引:21
作者
Basanta, M. [1 ,2 ]
Ibrahim, B. [1 ,2 ,3 ]
Douce, D. [4 ]
Morris, M. [4 ]
Woodcock, A. [1 ,2 ]
Fowler, S. J. [1 ,2 ,5 ]
机构
[1] Univ Manchester, Manchester Acad Hlth Sci Ctr, Fac Med & Human Sci, Resp Res Grp, Manchester, Lancs, England
[2] Univ S Manchester Hosp, NIHR Translat Res Facil Resp Med, Manchester M20 8LR, Lancs, England
[3] Univ Sains Malaysia, Sch Pharmaceut Sci, George Town, Malaysia
[4] Waters Corp, Manchester, Lancs, England
[5] Lancashire Teaching Hosp NHS Fdn Trust, Preston, Lancs, England
关键词
BREATH; PENTANE; ETHANE;
D O I
10.1088/1752-7155/6/2/026002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Robust methods for breath sampling and analysis are required for potential clinical applications. We have evaluated an improved sampling and experimental design, assessing instrumental and biological variability within and across breath measurements. Calibration curves for selected relevant volatile organic compounds (VOCs) were produced to look at the dynamic range and stability of analysis by gas chromatography/time-of-flight mass spectrometry. Linear responses were observed with R-2 > 95% and limits of detection in mid-range pg/mu l. Overall experimental design, visualized by means of principal component analysis, demonstrated good clustering on quality control samples, background air and blanks, with dispersion observed as expected across human breath samples. Serial sampling while breathing VOC-filtered air for up to 30 min demonstrated marked variation in reproducibility of VOCs, with median intraclass correlation coefficient of 0.29 (interquartile range 0.16-0.71), with no apparent effect of disease status. We have shown that we can reliably detect VOCs at very low concentrations in exhaled breath samples, and that the reproducibility depends on (a) compound of interest; (b) length of time breathing VOC-filtered air. These parameters will require investigation in studies of potential breath biomarkers, and must be standardized if tests are to become clinically useful.
引用
收藏
页数:9
相关论文
共 14 条
[1]  
Amann A, 2010, EUR RESPIR MONOGR, P96, DOI 10.1183/1025448x.00018509
[2]   An adaptive breath sampler for use with human subjects with an impaired respiratory function [J].
Basanta, M. ;
Koimtzis, T. ;
Singh, D. ;
Wilson, I. ;
Thomas, C. L. P. .
ANALYST, 2007, 132 (02) :153-163
[3]  
Basanta M, 2012, RESP RES UNPUB
[4]   Effects of ventilation on the collection of exhaled breath in humans [J].
Cope, KA ;
Watson, MT ;
Foster, WM ;
Sehnert, SS ;
Risby, TH .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (04) :1371-1379
[5]   Non-invasive phenotyping using exhaled volatile organic compounds in asthma [J].
Ibrahim, Baharudin ;
Basanta, Maria ;
Cadden, Paul ;
Singh, Dave ;
Douce, David ;
Woodcock, Ashley ;
Fowler, Stephen J. .
THORAX, 2011, 66 (09) :804-809
[6]   Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling [J].
Karl, T ;
Prazeller, P ;
Mayr, D ;
Jordan, A ;
Rieder, J ;
Fall, R ;
Lindinger, W .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (02) :762-770
[7]   Methods for measuring ethane and pentane in expired air from rats and humans [J].
Knutson, MD ;
Handelman, GJ ;
Viteri, FE .
FREE RADICAL BIOLOGY AND MEDICINE, 2000, 28 (04) :514-519
[8]  
Pennazza G, 2010, EUR RESPIR MONOGR, P115, DOI 10.1183/1025448x.00018609
[9]   Variation in volatile organic compounds in the breath of normal humans [J].
Phillips, M ;
Herrera, J ;
Krishnan, S ;
Zain, M ;
Greenberg, J ;
Cataneo, RN .
JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2) :75-88
[10]   Exposure reconstruction for reducing uncertainty in risk assessment: example using MTBE biomarkers and a simple pharmacokinetic model [J].
Pleil, J. D. ;
Kim, D. ;
Prah, J. D. ;
Rappaport, S. M. .
BIOMARKERS, 2007, 12 (04) :331-348