Vertical response of unbonded fiber reinforced elastomeric isolators (U-FREIs) under bidirectional shear loading

被引:1
作者
Galano, Simone [1 ]
机构
[1] Univ Naples Federico II, Dept Struct Engn & Architecture, Naples, Italy
关键词
fiber reinforced elastomeric isolators; seismic isolation; vertical stiffness; vertical displacements; effective compressive modulus; FINITE-ELEMENT-ANALYSIS; RUBBER BEARINGS; INSTABILITY; DESIGN; STEEL;
D O I
10.3389/fbuil.2022.1056187
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber Reinforced Elastomeric Isolators (FREIs) were generally studied in unbonded configuration. Due to combined axial and shear loads, the contact area between the bearing and horizontal supports reduces with the horizontal displacement. As a result, both the vertical and the horizontal stiffnesses decrease with the horizontal deformation while also the vertical deformation increases. This paper presents the results of a large set of full-scale 3D Finite Element Analyses on unbonded fiber reinforced bearings with different geometries, subjected to combined axial and multi-directional shear loads. The main vertical response parameters were studied, namely the vertical displacement, the vertical stiffness, and the effective compressive modulus, thus highlighting the influence of both geometry and horizontal loading direction on the vertical response of the FREIs. Conclusion of this study demonstrate to what extent the combined influence of geometric properties and loading conditions affects the vertical response of elastomeric bearings with flexible reinforcements.
引用
收藏
页数:13
相关论文
共 41 条
[1]   Vertical and Lateral Behavior of Unbonded Fiber-Reinforced Elastomeric Isolators [J].
Al-Anany, Yasser M. ;
Van Engelen, Niel C. ;
Tait, Michael J. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (05)
[2]   Carbon fiber-reinforced rectangular isolators with compressible elastomer: Analytical solution for compression and bending [J].
Angeli, Paolo ;
Russo, Gaetano ;
Paschini, Abramo .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2013, 50 (22-23) :3519-3527
[3]  
[Anonymous], 2010, Minimum design loads for buildings and other structures
[4]  
[Anonymous], 2005, MSC SOFTW CORP
[5]  
[Anonymous], 2017, MSC SOFTW CORP, VB
[6]   A parametric study on the stability of fiber reinforced rubber bearings under combined axial and shear loads [J].
Calabrese, Andrea ;
Spizzuoco, Mariacristina ;
Galano, Simone ;
Nghiem Tran ;
Strano, Salvatore ;
Terzo, Mario .
ENGINEERING STRUCTURES, 2021, 227
[7]   An experimental study on a novel reclaimed rubber compound for fiber-reinforced seismic isolators [J].
Cilento, Fabrizia ;
Losanno, Daniele ;
Piga, Luigi .
STRUCTURES, 2022, 45 :9-22
[8]  
Code P, 2005, Eurocode 8: Design of structures for earthquake resistance-part 1: general rules, seismic actions and rules for buildings
[9]   Stability of fiber-reinforced elastomeric bearings in an unbonded application [J].
de Raaf, Michael G. P. ;
Tait, Michael J. ;
Toopchi-Nezhad, Hamid .
JOURNAL OF COMPOSITE MATERIALS, 2011, 45 (18) :1873-1884
[10]  
Decree January 17, 2018, UPDATE TECHNICAL STA