Wrist-Sensor Pulse Oximeter Enables Prolonged Patient Monitoring in Chronic Lung Diseases

被引:23
作者
Guber, Alexander [1 ,2 ]
Shochet, Gali Epstein [1 ]
Kohn, Sarah [3 ]
Shitrit, David [1 ,2 ]
机构
[1] Meir Med Ctr, Pulm Dept, Tshernichovsky 59, IL-442801 Kefar Sava, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Oxitone Med, IL-4464312 Kefar Sava, Israel
关键词
Pulse oximetry; 6-min walk test; Device assessment; COPD; LONG-TERM OXYGEN; OBSTRUCTIVE PULMONARY-DISEASE; ACCURACY; THERAPY; TRIAL;
D O I
10.1007/s10916-019-1317-2
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Pulse oximetry is an important diagnostic tool in monitoring and treating both in-patients and ambulatory patients. Modern pulse oximeters exploit different body sites (eg fingertip, forehead or earlobe). All those are bulky and uncomfortable, resulting in low patient compliance. Therefore, we evaluated the accuracy and precision of a wrist-sensor pulse oximeter (Oxitone-1000, Oxitone Medical) vs. the traditional fingertip device. Fifteen healthy volunteers and 23 patients were recruited. The patient group included chronic obstructive pulmonary disease (COPD) (N=8), asthma (N=6), sarcoidosis (N=5) and others. Basic demographic data, skin tone type, smoking status and medical history were recorded. Blood oxygen level (SpO2) and pulse-rate values were determined by a non-invasive pulse oximeter (Reference, a conventional FDA-cleared fingertip pulse oximeter) and by Oxitone-1000. All tests were performed in singleton and in a blinded fashion. The measurements were done in sitting and standing positions, as well as after a 6-min walk test. The mean age was 60.4 +/- 9.83years, 55% were male. No significant differences were observed between the wrist-sensor and the traditional fingertip pulse oximeters in all tested parameters. Mean SpO2 was 96.45% vs. 97.18% and the mean pulse was 74.64 vs. 74.6bpm (Oxitone-1000 vs. Reference, respectively, p<0.0001). Precision rate was 2.28472% and the accuracy was met (Arms -Root mean-square-error<3%). The Oxitone-1000 is both accurate and precise for SpO2 and pulse measurements during daily activities of pulmonary patients, and is not inferior to standard devices for spot checking or short period examinations. Its wrist-sensor design is comfortable and provides the advantage of extended use.
引用
收藏
页数:7
相关论文
共 19 条
  • [1] A Randomized Trial of Long-Term Oxygen for COPD with Moderate Desaturation
    Albert, Richard K.
    Au, David H.
    Blackford, Amanda L.
    Casaburi, Richard
    Cooper, J. Allen, Jr.
    Criner, Gerard J.
    Diaz, Philip
    Fuhlbrigge, Anne L.
    Gay, Steven E.
    Kanner, Richard E.
    MacIntyre, Neil
    Martinez, Fernando J.
    Panos, Ralph J.
    Piantadosi, Steven
    Sciurba, Frank
    Shade, David
    Stibolt, Thomas
    Stoller, James K.
    Wise, Robert
    Yusen, Roger D.
    Tonascia, James
    Sternberg, Alice L.
    Bailey, William
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (17) : 1617 - 1627
  • [2] Assessing Agreement between Methods of Measurement
    Altman, Douglas G.
    Bland, J. Martin
    [J]. CLINICAL CHEMISTRY, 2017, 63 (10) : 1653 - 1654
  • [3] [Anonymous], 2017, MED ELECT EQUIPMEN 2
  • [4] Long term oxygen therapy in moderate hypoxaemia
    Anthonisen, NR
    [J]. THORAX, 1997, 52 (08) : 667 - 668
  • [5] Effects of skin pigmentation on pulse oximeter accuracy at low saturation
    Bickler, PE
    Feiner, JR
    Severinghaus, JW
    [J]. ANESTHESIOLOGY, 2005, 102 (04) : 715 - 719
  • [6] Bradley JM, 2005, COCHRANE DB SYST REV, V2
  • [7] ATS statement: Guidelines for the six-minute walk test
    Crapo, RO
    Casaburi, R
    Coates, AL
    Enright, PL
    MacIntyre, NR
    McKay, RT
    Johnson, D
    Wanger, JS
    Zeballos, RJ
    Bittner, V
    Mottram, C
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) : 111 - 117
  • [8] Dark Skin Decreases the Accuracy of Pulse Oximeters at Low Oxygen Saturation: The Effects of Oximeter Probe Type and Gender
    Feiner, John R.
    Severinghaus, John W.
    Bickler, Philip E.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 : S18 - S23
  • [9] Effect of long term oxygen therapy on survival in patients with chronic obstructive pulmonary disease with moderate hypoxaemia
    Gorecka, D
    Gorzelak, K
    Sliwinski, P
    Tobiasz, M
    Zielinski, J
    [J]. THORAX, 1997, 52 (08) : 674 - 679
  • [10] British Thoracic Society guidelines for home oxygen use in adults
    Hardinge, Maxine
    Annandale, Joe
    Bourne, Simon
    Cooper, Brendan
    Evans, Angela
    Freeman, Daryl
    Green, Angela
    Hippolyte, Sabrine
    Knowles, Vikki
    MacNee, William
    McDonnell, Lynn
    Pye, Kathy
    Suntharalingam, Jay
    Vora, Vandana
    Wilkinson, Tom
    [J]. THORAX, 2015, 70 : 1 - 43