Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels

被引:32
作者
Casciaro, Sergio [1 ,2 ]
Conversano, Francesco [1 ,2 ]
Musio, Stefano [1 ,2 ]
Casciaro, Ernesto [1 ,2 ]
Demitri, Christian [3 ]
Sannino, Alessandro [3 ]
机构
[1] CNR, IFC, Natl Res Council, Inst Clin Physiol, I-73100 Lecce, Italy
[2] Euro Mediterranean Sci Biomed Inst, Bioengn Div, Brindisi, Italy
[3] Univ Salento, Dept Engn Innovat, Lecce, Italy
关键词
ENHANCED ULTRASOUND; CONTRAST; IRRADIATION; DESTRUCTION; GEL;
D O I
10.1007/s10856-008-3644-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tissue mimicking phantoms have been widely reported to be an important tool for development, optimisation and performance testing of ultrasound-based diagnostic techniques. In particular, modern applications of tissue mimicking phantoms often include characterisation of the nonlinear behaviour of experimental ultrasound contrast agents. In such cases, the tissue-mimicking materials should be chosen not only based on the values of their density, speed of sound and attenuation coefficient, but also considering their effect on the appearance of "native harmonics" due to nonlinear distortion of ultrasound signal during propagation. In a previous paper it was demonstrated that a cellulose-based hydrogel is suitable to simulate nonlinear acoustical behaviour of liver tissue for thicknesses up to 8 cm. In this paper we present the experimental characterisation of the nonlinear acoustical behaviour of a different polyethylene glycol diacrylate (PEGDA)-based hydrogel, in order to assess whether and how it can improve the performances and overcome some limitations of the cellulose-based hydrogel as liver tissue-mimicking material. Samples of pig liver tissue, cellulose-based hydrogel and PEGDA-based hydrogel were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values. Second harmonic and first harmonic amplitudes were extracted from the spectra of received signals and their difference was then used to compare sample behaviours. Obtained results show how a new more accurate and combined experimental model of linear and nonlinear acoustical behaviour of liver tissue is feasible. In fact, a further confirmation of the cellulose-based hydrogel effectiveness to precisely simulate the liver tissue for penetration depths up to 8 cm was provided, and it was also shown that the employment of the PEGDA-based hydrogel can extend the range of useful tissue-mimicking material thicknesses up to 11 cm, moreover allowing a considerable improvement of the time stability and behaviour reliability of the corresponding manufactured phantoms.
引用
收藏
页码:983 / 989
页数:7
相关论文
共 29 条
  • [1] Biliary and reticuloendothelial impairment in hepatocarcinogenesis: the diagnostic role of tissue-specific MR contrast media
    Bartolozzi, Carlo
    Crocetti, Laura
    Lencioni, Riccardo
    Cioni, Dania
    Della Pina, Clotilde
    Campani, Daniela
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (10) : 2519 - 2530
  • [2] BAZZOCCHI M, 2001, ECOGRAFIA
  • [3] Casciaro S, 2005, ULTRASON, P1668
  • [4] Casciaro S, 2008, MINIM INVASIV THER, P113
  • [5] Experimental investigation and theoretical modelling of the nonlinear acoustical behaviour of a liver tissue and comparison with a tissue mimicking hydrogel
    Casciaro, Sergio
    Demitri, Christian
    Conversano, Francesco
    Casciaro, Ernesto
    Distante, Alessandro
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (02) : 899 - 906
  • [6] Experimental investigations of nonlinearities and destruction mechanisms of an experimental phospholipid-based ultrasound contrast agent
    Casciaro, Sergio
    Errico, Rosa Palmizio
    Conversano, Francesco
    Demitri, Christian
    Distante, Alessandro
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (02) : 95 - 104
  • [7] Conversano F, 2007, NEW TECHNOLOGY FRONT, P161
  • [8] Demitri C., 2008, J. Biomed. Mater. Res. Part B Appl. Biomater
  • [9] A freehand elastographic imaging approach for clinical breast imaging: System development and performance evaluation
    Doyley, MM
    Bamber, JC
    Fuechsel, F
    Bush, NL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (10) : 1347 - 1357
  • [10] Clinical utility of contrast-enhanced ultrasound in neurosonology
    Droste, Dirk W.
    [J]. EUROPEAN NEUROLOGY, 2008, 59 : 2 - 8