The efficacy of blind versus real-time ultrasound-guided percutaneous renal biopsy in developing country

被引:6
作者
Pongsittisak, Wanjak [1 ]
Wutilertcharoenwong, Naphat [1 ]
Ngamvichchukorn, Tanun [1 ]
Kurathong, Sathit [1 ]
Chavanisakun, Chutima [2 ]
Teepprasan, Tavichai [1 ]
Prommool, Surazee [1 ]
Srisawat, Nattachai [3 ]
机构
[1] Navamindradhiraj Univ, Vajira Hosp, Fac Med, Div Nephrol,Dept Med, 681 Samsen Rd, Bangkok 10300, Thailand
[2] Navamindradhiraj Univ, Fac Med, Dept Pathol, Vajira Hosp, Bangkok, Thailand
[3] Chulalongkorn Univ, Dept Med, Div Nephrol, Fac Med, Bangkok, Thailand
来源
SAGE OPEN MEDICINE | 2019年 / 7卷
关键词
Blind percutaneous renal biopsy; real-time ultrasound-guided percutaneous renal biopsy; native renal biopsy; transplant renal biopsy; efficacy of renal biopsy; KIDNEY BIOPSY; COMPLICATIONS; SAFETY; ADEQUACY; NEEDLES;
D O I
10.1177/2050312119849770
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Renal biopsy is a useful diagnostic procedure. In developing countries, two techniques of renal biopsy, blind percutaneous renal biopsy and real-time ultrasound-guided percutaneous renal biopsy, have been performed. The majority of studies compared these using different types and sizes of biopsy needle. The aim of this study was to compare both techniques in resource constraint country. Method: We reviewed renal biopsy database, between 1 January 2014 to 30 June 2017. The primary outcome was the total number of glomeruli. The other outcomes were tissue adequacy and bleeding complications. We also analyzed multivariable logistic regression to find factors associated with tissue adequacy and bleeding complications. Result: Of the 204 renal biopsies, 100 were blind percutaneous renal biopsy and 104 real-time ultrasound-guided percutaneous renal biopsy. The number of native renal biopsies was 169 (82.8%). Baseline characteristics of two groups were comparable. The mean number of total glomeruli from real-time ultrasound-guided percutaneous renal biopsy was significantly more than blind percutaneous renal biopsy (20.8 +/- 12.1 vs 16.0 +/- 13.0, p = 0.001). The real-time ultrasound-guided percutaneous renal biopsy obtained more adequate tissues than blind percutaneous renal biopsy (45.2% vs 16%, p < 0.001) and was the only factor associated with adequate tissue. Moreover, 16 renal biopsies from blind percutaneous renal biopsy obtained inadequate tissue. The overall bleeding complications were not statistically different. We found being female, lower eGFR and lower hematocrit were associated with bleeding complications. Conclusion: In comparison with blind percutaneous renal biopsy, real-time ultrasound-guided percutaneous renal biopsy obtained more adequate tissue and number of glomeruli. While the complications of both were comparable. We encourage to practice and perform real-time ultrasound-guided percutaneous renal biopsy in resource constraint countries.
引用
收藏
页数:7
相关论文
共 17 条
  • [1] Arora K, 2012, SAUDI J KIDNEY DIS T, V23, P88
  • [2] Comparative Safety and Efficiency of Five Percutaneous Kidney Biopsy Approaches of Native Kidneys: A Multicenter Study
    Bataille, Stanislas
    Jourde, Noemie
    Daniel, Laurent
    Mondain, Jean-Rene
    Faure, Magali
    Gobert, Pierre
    Alcheikh-Hassan, Zarih
    Lankester, Michel
    Giaime, Philippe
    Gaudart, Jean
    Dussol, Bertrand
    Berland, Yvon
    Burtey, Stephane
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 2012, 35 (05) : 387 - 393
  • [3] THE USE OF THE AUTOMATIC CORE BIOPSY SYSTEM IN PERCUTANEOUS RENAL BIOPSIES - A COMPARATIVE-STUDY
    BURSTEIN, DM
    KORBET, SM
    SCHWARTZ, MM
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 22 (04) : 545 - 552
  • [4] Cameron JS, 1997, AM J NEPHROL, V17, P347
  • [5] Adequacy and Complication Rates with 14-vs. 16-gauge Automated Needles in Percutaneous Renal Biopsy of Native Kidneys
    Chunduri, Svetha
    Whittier, William L.
    Korbet, Stephen M.
    [J]. SEMINARS IN DIALYSIS, 2015, 28 (02) : E11 - E14
  • [6] Safety and tissue yield for percutaneous native kidney biopsy according to practitioner and ultrasound technique
    Chung, Sungjin
    Koh, Eun Sil
    Kim, Sung Jun
    Yoon, Hye Eun
    Park, Cheol Whee
    Chang, Yoon Sik
    Shin, Seok Joon
    [J]. BMC NEPHROLOGY, 2014, 15
  • [7] Bleeding Complications of Native Kidney Biopsy: A Systematic Review and Meta-analysis
    Corapi, Kristin M.
    Chen, Joline L. T.
    Balk, Ethan M.
    Gordon, Craig E.
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2012, 60 (01) : 62 - 73
  • [8] CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY
    COZENS, NJA
    MURCHISON, JT
    ALLAN, PL
    WINNEY, RJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) : 594 - 597
  • [9] Safety and adequacy of percutaneous kidney biopsy performed by nephrology trainees
    Esposito, Vittoria
    Mazzon, Giulia
    Baiardi, Paola
    Torreggiani, Massimo
    Semeraro, Luca
    Catucci, Davide
    Colucci, Marco
    Mariotto, Alice
    Grosjean, Fabrizio
    Bovio, Giacomo
    Esposito, Ciro
    [J]. BMC NEPHROLOGY, 2018, 19
  • [10] A randomized, prospective, comparative study of manual and automated renal biopsies
    Kim, D
    Kim, H
    Shin, G
    Ku, S
    Ma, KG
    Shin, S
    Gi, H
    Lee, E
    Yim, H
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 32 (03) : 426 - 431