Orthogonal relationships between ultrasonic velocity and material properties of bovine cancellous bone

被引:86
|
作者
Njeh, CF
Hodgskinson, R
Currey, JD
Langton, CM
机构
[1] UNIV HULL,ACAD DEPT MED PHYS,KINGSTON HULL HU6 7RX,N HUMBERSIDE,ENGLAND
[2] SHEFFIELD HALLAM UNIV,HLTH RES INST,SHEFFIELD S1 1WB,S YORKSHIRE,ENGLAND
[3] UNIV YORK,DEPT BIOL,YORK YO1 5DD,N YORKSHIRE,ENGLAND
关键词
cancellous bone; ultrasound velocity; Young's modulus; compressive strength;
D O I
10.1016/1350-4533(95)00064-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Osteoporotic fractures follow a period of asymptomatic bone loss and hence bone strength, predominantly in cancellous bone. An effective management of osteoporosis requires an understanding of the mechanical behaviour of cancellous bone including the anisotropic dependence. Ultrasound velocity (V) and elasticity (Young's modulus, E) were measured In the three orthogonal directions in 20 mm cubes of bovine cancellous bone. Student paired t-test analysis showed significant variations in velocity and elasticity for the three orthogonal directions, the highest significance being between proximal-distal (PD) and antero-posterior (AP) directions with t = 5.63 and 4.09 for velocity and elasticity respectively, the lowest significance between medio-lateral (ML) and antero-posterior directions. Elasticity followed a power law relationship with apparent density (rho) as reported in the literature, the exponent (b) being direction dependent (b = 1.98 +/- 0.21 for PD, 2.42 +/- 0.24 for AP and 2.03 +/- 0.17 for ML). The adjusted R(2) values between elasticity and apparent density were highly significant (79.9% for PD, 81.9% for AP and 85.7% for ML). The relationship between velocity and apparent density is less significant in terms of the amount of variance explained (48.5% for PD, 63.3% for AP and 64.4% for ML). R(2) values relating elasticity and velocity were again highly significant (79.4% for PD, 82.9% for AP and 80.5% for ML) and the coefficients, determined by regression analysis, independent of direction. Analysis of velocity, elasticity and density data for a range of reference materials demonstrated that experimentally measured longitudinal wave velocity could be reliably substituted into the bar wave equation (v = root E/rho). This implies that a combination of velocity and apparent density may be an improved indicator of bone fragility than density alone. Copyright (C) 1996 Elsevier Science Ltd for IPEMB.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 50 条
  • [41] A CONTACT METHOD FOR THE ASSESSMENT OF ULTRASONIC VELOCITY AND BROAD-BAND ATTENUATION IN CORTICAL AND CANCELLOUS BONE
    LANGTON, CM
    ALI, AV
    RIGGS, CM
    EVANS, GP
    BONFIELD, W
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03): : 243 - 249
  • [42] On the Prediction of Young’s Modulus in Calcaneal Cancellous Bone by Ultrasonic Bulk and Bar Velocity Measurements
    P. H. F. Nicholson
    R. Strelitzki
    Clinical Rheumatology, 1999, 18 : 10 - 16
  • [43] On the prediction of Young's modulus in calcaneal cancellous bone by ultrasonic bulk and bar velocity measurements
    Nicholson, PHF
    Strelitzki, R
    CLINICAL RHEUMATOLOGY, 1999, 18 (01) : 10 - 16
  • [44] Mimetization of the elastic properties of cancellous bone via a parameterized cellular material
    Colabella, Lucas
    Cisilino, Adrian P.
    Haiat, Guillaume
    Kowalczyk, Piotr
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2017, 16 (05) : 1485 - 1502
  • [45] Mimetization of the elastic properties of cancellous bone via a parameterized cellular material
    Lucas Colabella
    Adrián P. Cisilino
    Guillaume Häiat
    Piotr Kowalczyk
    Biomechanics and Modeling in Mechanobiology, 2017, 16 : 1485 - 1502
  • [46] Variation of human cancellous bone ultrasonic properties with density and micro-structure
    Chaffaî, S
    Peyrin, F
    Berger, G
    Laugier, P
    1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1303 - 1306
  • [47] CANCELLOUS BONE MATERIAL PROPERTIES IN OSTEOARTHRITIC AND RHEUMATOID TOTAL KNEE PATIENTS
    WIXSON, RL
    ELASKY, N
    LEWIS, J
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) : 885 - 892
  • [48] Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements:: Relationships to density and microstructure
    Chaffaî, S
    Peyrin, F
    Nuzzo, S
    Porcher, R
    Berger, G
    Laugier, P
    BONE, 2002, 30 (01) : 229 - 237
  • [49] Correlations between ultrasonic guided wave velocities and bone properties in bovine tibia in vitro
    Lee, Kang Il
    Yoon, Suk Wang
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (05): : EL375 - EL381
  • [50] An ultrasonic method for measuring the elastic properties of human tibial cortical and cancellous bone
    Rho, JY
    ULTRASONICS, 1996, 34 (08) : 777 - 783