Automated 2D Ultrasound Fusion Imaging of Abdominal Aortic Aneurysms

被引:1
|
作者
Lopata, R. G. P. [1 ]
Meesters, S. P. L. [1 ]
Nguyen, V. L.
Schurink, G. W. H.
van de Vosse, F. N. [1 ]
机构
[1] Eindhoven Univ Technol, Cardiovasc Biomech Grp, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
来源
2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2012年
关键词
fusion; abdominal aortic aneurysms; image registration; ultrasound;
D O I
10.1109/ULTSYM.2012.0087
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent studies reveal the benefits of ultrasound strain imaging and elastography of abdominal aortic aneurysms (AAAs). However, feasibility and reproducibility of these techniques is not trivial due to the low imaging depth and low contrast of the US data. Beam-steering overcomes these problems in superficial arteries, but is not applicable for AAAs. Multi-angle acquisition could improve both aortic wall segmentation and strain imaging in a similar fashion. In this study, an automated technique for fusion of two-dimensional images, acquired manually at different positions, was developed and applied to ultrasound data of AAAs (n = 5). It was attempted to acquire images at -45, 0 and 45 degrees. Feature points were detected using a scale-space approach and were clustered based on anisotropy of the neighborhood. Next, an ellipsoid was fit through the remaining points. By registering these ellipses, the three different images were compounded. Initial results reveal that the method is able to perform automated registration. The estimated angle between the left and middle images was -25 degrees +/- 16 degrees and was 37 degrees +/- 15 degrees between the middle and right position (n = 4). The ellipsoid fit showed more variation in lateral direction. However, additional features should be considered for registration. Results suggest that automated wall thickness assessment might be possible using the extracted feature points.
引用
收藏
页码:354 / 357
页数:4
相关论文
共 50 条
  • [31] Contrast-enhanced ultrasound microbubble uptake and abnormal plasma biomarkers are seen in patients with abdominal aortic aneurysms
    Ali, Adham N. Abou
    Cherfan, Patrick
    Taha, Ashraf G.
    Makaroun, Michel S.
    Zhang, Yingze
    Chen, Xucai X.
    Villanueva, Flordeliza S.
    Chaer, Rabih A.
    JVS-VASCULAR SCIENCE, 2025, 6
  • [32] Automatic Segmentation and Mechanical Characterisation of the Intraluminal Thrombus and Arterial Wall of Abdominal Aortic Aneurysms Using Time Resolved 3D Ultrasound Images
    Nievergeld, Arjet Helena Margaretha
    Maas, Esther Jorien
    de Ruijter, Joerik
    Fonken, Judith Helena Cornelia
    van Sambeekan, Marcus Rodolph Henricus Maria
    Lopata, Richard Godfried Paulus
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2023, 66 (03) : 418 - 427
  • [33] Real Time Cardiac SPECT and 2D Ultrasound Image Registration
    Bucki, Marek
    Chassat, Fabrice
    Galdames, Francisco
    Asahi, Takeshi
    Pizarro, Daniel
    Lobo, Gabriel
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 235 - +
  • [34] Efficient automatic 2D/3D registration of cardiac ultrasound and CT images
    Scott, Katy
    Stuart, Duncan
    Peoples, Jacob J.
    Bisleri, Gianluigi
    Ellis, Randy E.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2021, 9 (04) : 438 - 446
  • [35] Pharmacological Inhibition of Gasdermin D Suppresses Angiotensin II-Induced Experimental Abdominal Aortic Aneurysms
    Guo, Jia
    Shi, Jinyun
    Qin, Min
    Wang, Yan
    Li, Zhidong
    Shoji, Takahiro
    Ikezoe, Toru
    Ge, Yingbin
    Xu, Baohui
    BIOMOLECULES, 2023, 13 (06)
  • [36] Ultrasound-Based Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms Incorporating Pre-stress
    Fonken, Judith H. C.
    Maas, Esther J.
    Nievergeld, Arjet H. M.
    van Sambeek, Marc R. H. M.
    van de Vosse, Frans N.
    Lopata, Richard G. P.
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [37] Automated Left Ventricle Dimension Measurement in 2D Cardiac Ultrasound via an Anatomically Meaningful CNN Approach
    Gilbert, Andrew
    Holden, Marit
    Eikvil, Line
    Aase, Svein Arne
    Samset, Eigil
    McLeod, Kristin
    SMART ULTRASOUND IMAGING AND PERINATAL, PRETERM AND PAEDIATRIC IMAGE ANALYSIS, SUSI 2019, PIPPI 2019, 2019, 11798 : 29 - 37
  • [38] 2D LOCALIZATION OF SPECULAR REFLECTIONS USING ULTRASOUND
    Bandaru, Raja Sekhar
    Sornes, Anders
    D'hooge, Jan
    Samset, Eigil
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2209 - 2212
  • [39] Diaphragm ultrasound and diaphragmatic 2D speckle tracking imaging in acute heart failure: a case series
    Fayssoil, Abdallah
    De Chazournes, Pierre Boisson
    Hauguel-Moreau, Marie
    Mansart, Arnaud
    Mansencal, Nicolas
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2024, 8 (12)
  • [40] Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation
    Romero, X. C.
    Molina, F. S.
    Pastor, E.
    Amaya, F.
    FETAL DIAGNOSIS AND THERAPY, 2011, 29 (03) : 257 - 260