Automated 2D Ultrasound Fusion Imaging of Abdominal Aortic Aneurysms

被引:1
|
作者
Lopata, R. G. P. [1 ]
Meesters, S. P. L. [1 ]
Nguyen, V. L.
Schurink, G. W. H.
van de Vosse, F. N. [1 ]
机构
[1] Eindhoven Univ Technol, Cardiovasc Biomech Grp, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
来源
2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2012年
关键词
fusion; abdominal aortic aneurysms; image registration; ultrasound;
D O I
10.1109/ULTSYM.2012.0087
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent studies reveal the benefits of ultrasound strain imaging and elastography of abdominal aortic aneurysms (AAAs). However, feasibility and reproducibility of these techniques is not trivial due to the low imaging depth and low contrast of the US data. Beam-steering overcomes these problems in superficial arteries, but is not applicable for AAAs. Multi-angle acquisition could improve both aortic wall segmentation and strain imaging in a similar fashion. In this study, an automated technique for fusion of two-dimensional images, acquired manually at different positions, was developed and applied to ultrasound data of AAAs (n = 5). It was attempted to acquire images at -45, 0 and 45 degrees. Feature points were detected using a scale-space approach and were clustered based on anisotropy of the neighborhood. Next, an ellipsoid was fit through the remaining points. By registering these ellipses, the three different images were compounded. Initial results reveal that the method is able to perform automated registration. The estimated angle between the left and middle images was -25 degrees +/- 16 degrees and was 37 degrees +/- 15 degrees between the middle and right position (n = 4). The ellipsoid fit showed more variation in lateral direction. However, additional features should be considered for registration. Results suggest that automated wall thickness assessment might be possible using the extracted feature points.
引用
收藏
页码:354 / 357
页数:4
相关论文
共 50 条
  • [1] Strain estimation in abdominal aortic aneurysms from 2-D ultrasound
    Brekken, R
    Bang, J
    Odegard, A
    Aasland, J
    Hernes, TAN
    Myhre, HO
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (01) : 33 - 42
  • [2] 3D visualization of strain in abdominal aortic aneurysms based on navigated ultrasound imaging
    Brekken, Reidar
    Kaspersen, Jon Harald
    Tangen, Geir Arne
    Dahl, Torbjorn
    Hernes, Toril A. N.
    Myhre, Hans Olav
    MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2007, 6511
  • [3] Ultrasound Based Wall Stress Analysis of Abdominal Aortic Aneurysms using Multiperspective Imaging
    van Disseldorp, Emiel M. J.
    van Dronkelaar, Julia J.
    Pluim, Josien P. W.
    van de Vosse, Frans N.
    van Sambeek, Marc R. H. M.
    Lopata, Richard G. P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (01) : 81 - 91
  • [4] Longitudinal study on 3D ultrasound-based rupture risk assessment of abdominal aortic aneurysms
    Nievergeld, Arjet
    Fonken, Judith
    Thirugnanasambandam, Mirunalini
    Maas, Esther
    van Sambeek, Marc
    Lopata, Richard
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2025, 26 (04) : 741 - 752
  • [5] Current Imaging Strategies in Patients with Abdominal Aortic Aneurysms
    Ristow, Inka
    Riedel, Christoph
    Lenz, Alexander
    Well, Lennart
    Adam, Gerhard
    Panuccio, Giuseppe
    Kolbel, Tilo
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (01): : 52 - 61
  • [6] Deep learning-based segmentation of abdominal aortic aneurysms and intraluminal thrombus in 3D ultrasound images
    Nievergeld, Arjet
    Cetinkaya, Bunyamin
    Maas, Esther
    van Sambeek, Marc
    Lopata, Richard
    Awasthi, Navchetan
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024,
  • [7] Noninvasive measurement of abdominal aortic aneurysms in intact mice by a high-frequency ultrasound imaging system
    Martin-McNulty, B
    Vincelette, J
    Vergona, R
    Sullivan, ME
    Wang, YX
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06) : 745 - 749
  • [8] Robotic Needle Insertion With 2D Ultrasound–3D CT Fusion Guidance
    Lei, Long
    Zhao, Baoliang
    Qi, Xiaozhi
    Mi, Rui
    Ye, Hai
    Zhang, Peng
    Wang, Qiong
    Heng, Pheng-Ann
    Hu, Ying
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2024, 21 (04) : 6152 - 6164
  • [9] SPATIOTEMPORAL REGISTRATION OF 3-D MULTI-PERSPECTIVE ULTRASOUND IMAGES OF ABDOMINAL AORTIC ANEURYSMS
    Sjoerdsma, Marloes
    Verstraeten, Sabine C. F. P. M.
    Maas, Esther J.
    Van De Vosse, Frans N.
    Van Sambeek, Marc R. H. M.
    Lopata, Richard G. P.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (01) : 318 - 332
  • [10] Compliance of abdominal aortic aneurysms: Evaluation of tissue doppler imaging
    Long, A
    Rouet, L
    Bissery, A
    Rossignol, P
    Mouradian, D
    Sapoval, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (09) : 1099 - 1108