Co-generation of electricity and heating using a SOFC-ScCO2 Brayton cycle-ORC integrated plant: Investigation and multi-objective optimization

被引:43
作者
Mojaver, Parisa [1 ]
Abbasalizadeh, Majid [1 ]
Khalilarya, Shahram [1 ]
Chitsaz, Ata [1 ]
机构
[1] Urmia Univ, Dept Mech Engn, Fac Engn, Orumiyeh, Iran
关键词
Co-generation plant; Central composite design; Lagrange method; Multi-objective optimization; OXIDE FUEL-CELL; ORGANIC RANKINE-CYCLE; MICRO-COMBINED HEAT; POWER-GENERATION; GAS-TURBINE; PERFORMANCE ASSESSMENT; EXERGY ANALYSIS; THERMODYNAMIC ANALYSIS; BIOMASS GASIFICATION; SYSTEM;
D O I
10.1016/j.ijhydene.2020.07.137
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A co-generation plant consisting of a solid oxide fuel cell, a supercritical carbon dioxide Brayton cycle, an organic Rankine cycle, and a domestic heat recovery was modeled based on the zero-dimensional approach. The minimization of Gibbs free energy and Lagrange method of undetermined multipliers were applied to find the unknown moles in the reactions. The effects of the current density, the fuel utilization ratio, and the anode recycle ratio were investigated on the plant performance. Net power, heated water and fuel flow rates, energy and exergy efficiencies, and CO2 emission were considered as outputs of the co-generation plant. The contributions of the parameters were determined using analysis of variance results and half-normal plot of the standardized effects. The regression models of the outputs were achieved with high credibility. The findings indicated that the current density had the highest contribution to plant performance. The multi-objective optimization showed that the current density of 7787.879 A/m(2) and the anode recycle ratio of 0.424 is the optimum condition. In this state, the electrical exergy efficiency, the heated water flow rate, and the CO2 co-generation emission were 43.01%, 2769 gr/s, and 213.6 kg/(MW.h), respectively. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:27713 / 27729
页数:17
相关论文
共 58 条
[1]   Optimum exergetic performance parameters and thermo-sustainability indicators of low-temperature modified organic Rankine cycles (ORCs) [J].
Abam, F. I. ;
Ekwe, E. B. ;
Effiom, S. O. ;
Ndukwu, M. C. ;
Briggs, T. A. ;
Kadurumba, C. H. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 30 :91-104
[2]   Exergoeconoenvironmental analysis as a new concept for developing thermodynamically, economically, and environmentally sound energy conversion systems [J].
Aghbashlo, Mortaza ;
Rosen, Marc A. .
JOURNAL OF CLEANER PRODUCTION, 2018, 187 :190-204
[3]   Exergy analysis of a lignocellulosic-based biorefinery annexed to a sugarcane mill for simultaneous lactic acid and electricity production [J].
Aghbashlo, Mortaza ;
Mandegari, Mohsen ;
Tabatabaei, Meisam ;
Farzad, Somayeh ;
Soufiyan, Mohamad Mojarab ;
Gorgens, Johann F. .
ENERGY, 2018, 149 :623-638
[4]   Electrochemical model for performance analysis of a tubular SOFC [J].
Akkaya, Ali Volkan .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (01) :79-98
[5]   Energy analysis of a trigeneration plant based on solid oxide fuel cell and organic Rankine cycle [J].
Al-Sulaiman, Fahad A. ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) :5104-5113
[6]   Energy and exergy analyses of solar tower power plant driven supercritical carbon dioxide recompression cycles for six different locations [J].
Atif, Maimoon ;
Al-Sulaiman, Fahad A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 68 :153-167
[7]   Energy and exergy analysis of simple solid-oxide fuel-cell power systems [J].
Chan, SH ;
Low, CF ;
Ding, OL .
JOURNAL OF POWER SOURCES, 2002, 103 (02) :188-200
[8]   Thermodynamic modeling of direct internal reforming solid oxide fuel cells operating with syngas [J].
Colpan, C. Ozgur ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (07) :787-795
[9]   Supercritical carbon dioxide cycles for power generation: A review [J].
Crespi, Francesco ;
Gavagnin, Giacomo ;
Sanchez, David ;
Martinez, Gonzalo S. .
APPLIED ENERGY, 2017, 195 :152-183
[10]   Exergy evaluation and ORC use as an alternative for efficiency improvement in a CI-engine power plant [J].
da Silva, Julio A. M. ;
Seifert, Vitor ;
de Morais, Vinicius O. B. ;
Tsolakis, Athanasios ;
Herreros, Jose ;
Torres, Ednildo .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 30 :216-223