Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy

被引:57
作者
Richter, D. [1 ,2 ]
Schwarzkopf, A. [1 ,2 ]
Trautmann, J. [1 ,2 ]
Kraemer, M. [1 ]
Durante, M. [1 ,2 ]
Jaekel, O. [3 ]
Bert, C. [1 ,4 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Abt Biophys, D-64291 Darmstadt, Germany
[2] Tech Univ Darmstadt, D-64289 Darmstadt, Germany
[3] Heidelberg Univ, Clin Radiat Oncol, D-69120 Heidelberg, Germany
[4] Univ Hosp Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
关键词
radiotherapy; treatment planning; four-dimensional; ion beam; organ motion; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; PARTICLE THERAPY; DEFORMABLE REGISTRATION; IMAGE REGISTRATION; RADIATION-THERAPY; TREATMENT PLANS; TUMOR MOTION; ORGAN MOTION; PROTON-BEAM;
D O I
10.1118/1.4800802
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused by patient motion and dynamic beam delivery. Methods: The 4DTPS integrates data interfaces to 4D computed tomography (4DCT), deformable image registration and clinically used motion monitoring devices. The authors implemented a novel data model for 4D image segmentation using Boolean mask volume datasets and developed an algorithm propagating a manually contoured reference contour dataset to all 4DCT phases. They further included detailed treatment simulation and dose reconstruction functionality, based on the irregular patient motion and the temporal structure of the beam delivery. The treatment simulation functionality was validated against experimental data from irradiation of moving radiographic films in air, 3D moving ionization chambers in a water phantom, and moving cells in a biological phantom with a scanned carbon ion beam. The performance of the program was compared to results obtained with predecessor programs. Results: The measured optical density distributions of the radiographic films were reproduced by the simulations to (-2 +/- 12)%. Compared to earlier versions of the 4DTPS, the mean agreement improved by 2%, standard deviations were reduced by 7%. The simulated dose to the moving ionization chambers in water showed an agreement with the measured dose of (-1 +/- 4)% for the typical beam configuration. The mean deviation of the simulated from the measured biologically effective dose determined via cell survival was (617 +/- 538) mGy relative biological effectiveness corresponding to (10 +/- 9)%. Conclusions: The authors developed a research 4DTPS suitable for realistic treatment planning on patient data and capable of simulating dose delivery to a moving patient geometry for scanned ion beams. The accuracy and reliability of treatment simulations improved considerably with respect to earlier versions of the 4DTPS. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Treatment planning for scanned ion beams
    Krämer, M
    Jäkel, O
    Haberer, T
    Rietzel, E
    Schardt, D
    Scholz, M
    Wang, JF
    Weber, U
    Weyrather, W
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S80 - S85
  • [22] First 4D In-beam PET Measurement for Beam Tracking of a Moving Phantom with a Scanned Carbon Ion Beam
    Parodi, K.
    Saito, N.
    Richter, C.
    Chaudhri, N.
    Enghardt, W.
    Rietzel, E.
    Bert, C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3794 - +
  • [23] Limitations of phase-sorting based pencil beam scanned 4D proton dose calculations under irregular motion
    Duetschler, A.
    Prendi, J.
    Safai, S.
    Weber, D. C.
    Lomax, A. J.
    Zhang, Ye
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (01)
  • [24] Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams
    Saito, Nami
    Bert, Christoph
    Chaudhri, Naved
    Gemmel, Alexander
    Schardt, Dieter
    Durante, Marco
    Rietzel, Eike
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16) : 4849 - 4862
  • [25] Log file-based dose reconstruction and accumulation for 4D adaptive pencil beam scanned proton therapy in a clinical treatment planning system: Implementation and proof-of-concept
    Meijers, A.
    Jakobi, A.
    Stuetzer, K.
    Guterres Marmitt, G.
    Both, S.
    Langendijk, J. A.
    Richter, C.
    Knopf, A.
    MEDICAL PHYSICS, 2019, 46 (03) : 1140 - 1149
  • [26] Feature-based plan adaptation for fast treatment planning in scanned ion beam therapy
    Chen, Wenjing
    Gemmel, Alexander
    Rietzel, Eike
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 1013 - 1025
  • [27] Scanned ion beam therapy for prostate carcinoma
    Hild, Sebastian
    Graeff, Christian
    Rucinski, Antoni
    Zink, Klemens
    Habl, Gregor
    Durante, Marco
    Herfarth, Klaus
    Bert, Christoph
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 118 - 126
  • [28] Development of a novel post-processing treatment planning platform for 4D radiotherapy
    Lin, Lan
    Shi, Chengyu
    Liu, Yaxi
    Swanson, Gregory
    Papanikolaou, Nikos
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (02) : 125 - 132
  • [29] Challenges of radiotherapy: Report on the 4D treatment planning workshop 2013
    Knopf, Antje
    Nill, Simeon
    Yohannes, Indra
    Graeff, Christian
    Dowdell, Stephen
    Kurz, Christopher
    Sonke, Jan-Jakob
    Biegun, Aleksandra K.
    Lang, Stephanie
    McClelland, Jamie
    Champion, Benjamin
    Fast, Martin
    Wolfelschneider, Jens
    Gianoli, Chiara
    Rucinski, Antoni
    Baroni, Guido
    Richter, Christian
    van de Water, Steven
    Grassberger, Clemens
    Weber, Damien
    Poulsen, Per
    Shimizu, Shinichi
    Bert, Christoph
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 809 - 815
  • [30] A review of the clinical introduction of 4D particle therapy research concepts
    Knaeusl, Barbara
    Belotti, Gabriele
    Bertholet, Jenny
    Daartz, Juliane
    Flampouri, Stella
    Hoogeman, Mischa
    Knopf, Antje C.
    Lin, Haibo
    Moerman, Astrid
    Paganelli, Chiara
    Rucinski, Antoni
    Schulte, Reinhard
    Shimizu, Shing
    Stuetzer, Kristin
    Zhang, Xiaodong
    Zhang, Ye
    Czerska, Katarzyna
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29