Ultra-Low Power Sensor Devices for Monitoring Physical Activity and Respiratory Frequency in Farmed Fish

被引:30
作者
Antonio Martos-Sitcha, Juan [1 ,2 ]
Sosa, Javier [3 ]
Ramos-Valido, Dailos [3 ]
Javier Bravo, Francisco [4 ]
Carmona-Duarte, Cristina [5 ]
Leonel Gomes, Henrique [6 ]
Alvar Calduch-Giner, Josep [1 ]
Cabruja, Enric [4 ]
Vega, Aurelio [3 ]
Angel Ferrer, Miguel [5 ]
Lozano, Manuel [4 ]
Antonio Montiel-Nelson, Juan [3 ]
Manuel Afonso, Juan [7 ]
Perez-Sanchez, Jaume [1 ]
机构
[1] CSIC, Nutrigen & Fish Growth Endocrinol Grp, Inst Aquaculture Torre de la Sal, Castellon de La Plana, Spain
[2] Univ Cadiz, Inst Univ Invest Marina INMAR, Fac Marine & Environm Sci, Dept Biol,Campus Excelencia Int Mar CEI MAR, Cadiz, Spain
[3] Univ Las Palmas Gran Canaria, Inst Appl Microelect IUMA, Las Palmas Gran Canaria, Spain
[4] CSIC, Inst Microelect Barcelona IMB CNM, Barcelona, Spain
[5] Univ Las Palmas Gran Canaria, Technol Ctr Innovat Commun iDeTIC, Las Palmas Gran Canaria, Spain
[6] Univ Algarve, Ctr Marine Sci CCMAR, Faro, Portugal
[7] Univ Las Palmas Gran Canaria, Aquaculture Res Grp, Inst Sustainable Aquaculture & Marine Ecosyst IU, Las Palmas Gran Canaria, Spain
来源
FRONTIERS IN PHYSIOLOGY | 2019年 / 10卷
关键词
aquaculture; sensor; swimming tests; fish welfare; physical activity; respiratory frequency; oxygen consumption; EUROPEAN SEA BASS; SWIMMING SPEED; RAINBOW-TROUT; GAIT TRANSITION; TEMPERATURE; METABOLISM; BEHAVIOR; PHYSIOLOGY; PERFORMANCE; RESPONSES;
D O I
10.3389/fphys.2019.00667
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Integration of technological solutions aims to improve accuracy, precision and repeatability in farming operations, and biosensor devices are increasingly used for understanding basic biology during livestock production. The aim of this study was to design and validate a miniaturized tri-axial accelerometer for non-invasive monitoring of farmed fish with re-programmable schedule protocols. The current device (AE-FishBIT v.1s) is a small (14 mm x 7 mm x 7 mm), stand-alone system with a total mass of 600 mg, which allows monitoring animals from 30 to 35 g onwards. The device was attached to the operculum of gilthead sea bream (Sparus aurata) and European sea bass (Dicentrarchus labrax) juveniles for monitoring their physical activity by measurements of movement accelerations in x- and y-axes, while records of operculum beats (z-axis) served as a measurement of respiratory frequency. Data post-processing of exercised fish in swimming test chambers revealed an exponential increase of fish accelerations with the increase of fish speed from 1 body-length to 4 body-lengths per second, while a close relationship between oxygen consumption (MO2) and opercular frequency was consistently found. Preliminary tests in free-swimming fish kept in rearing tanks also showed that device data recording was able to detect changes in daily fish activity. The usefulness of low computational load for data pre-processing with on-board algorithms was verified from low to submaximal exercise, increasing this procedure the autonomy of the system up to 6 h of data recording with different programmable schedules. Visual observations regarding tissue damage, feeding behavior and circulating levels of stress markers (cortisol, glucose, and lactate) did not reveal at short term a negative impact of device tagging. Reduced plasma levels of triglycerides revealed a transient inhibition of feed intake in small fish (sea bream 50-90 g, sea bass 100-200 g), but this disturbance was not detected in larger fish. All this considered together is the proof of concept that miniaturized devices are suitable for non-invasive and reliable metabolic phenotyping of farmed fish to improve their overall performance and welfare. Further work is underway for improving the attachment procedure and the full device packaging.
引用
收藏
页数:14
相关论文
共 60 条
  • [21] Hinch S. G., 2006, BEHAV PHYSL FISH, V24, P240
  • [22] Horie J., 2017, Anim Biotelem, V5, particl, DOI [10.1186/s40317-017-0127-x, DOI 10.1186/S40317-017-0127-X]
  • [23] Precision Farming: Sensor Analytics
    Ivanov, Stepan
    Bhargava, Kriti
    Donnelly, William
    [J]. IEEE INTELLIGENT SYSTEMS, 2015, 30 (04) : 76 - 80
  • [24] Jepsen N., 2015, Animal Biotelemetry, V3, P1, DOI DOI 10.1186/S40317-015-0086-Z
  • [25] Jepsen N., 2004, P 5 C FISH TEL UST, P255
  • [26] Limits to exhaustive exercise in fish
    Kieffer, JD
    [J]. COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR AND INTEGRATIVE PHYSIOLOGY, 2000, 126 (02): : 161 - 179
  • [27] The use of acoustic acceleration transmitter tags for monitoring of Atlantic salmon swimming activity in recirculating aquaculture systems (RAS)
    Kolarevic, J.
    Aas-Hansen, O.
    Espmark, A.
    Baeverfjord, G.
    Terjesen, B. Fyhn
    Damsgard, B.
    [J]. AQUACULTURAL ENGINEERING, 2016, 72-73 : 30 - 39
  • [28] Recent Advances and New Trends in Flip Chip Technology
    Lau, John H.
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2016, 138 (03)
  • [29] Excess post-exercise oxygen consumption in adult sockeye (Oncorhynchus nerka) and coho (O-kisutch) salmon following critical speed swimming
    Lee, CG
    Farrell, AP
    Lotto, A
    Hinch, SG
    Healey, MC
    [J]. JOURNAL OF EXPERIMENTAL BIOLOGY, 2003, 206 (18) : 3253 - 3260
  • [30] Underwater Wireless Sensor Communications in the 2.4 GHz ISM Frequency Band
    Lloret, Jaime
    Sendra, Sandra
    Ardid, Miguel
    Rodrigues, Joel J. P. C.
    [J]. SENSORS, 2012, 12 (04) : 4237 - 4264