Determination of rhodium by resonance light-scattering technique coupled with solid phase extraction using Rh(III) ion-imprinted polymers as sorbent

被引:16
作者
Yang, Bing [1 ]
Zhang, Ting [1 ]
Tan, Wenxiang [1 ]
Liu, Peng [1 ]
Ding, Zhongtao [1 ]
Cao, Qiue [1 ]
机构
[1] Yunnan Univ, Minist Educ, Key Lab Med Chem Nat Resource, Sch Chem Sci & Technol, Kunming 650091, Peoples R China
关键词
Rhodium; Ion imprinted polymer; Resonance light-scattering technique; Solid-phase extraction; ATOMIC-ABSORPTION-SPECTROMETRY; ORIGINS UNTIL TODAY; CLOUD POINT EXTRACTION; ENVIRONMENTAL-SAMPLES; PRECONCENTRATIVE SEPARATION; SELECTIVE RECOGNITION; TRACE DETERMINATION; PALLADIUM; PARTICLES; FAAS;
D O I
10.1016/j.talanta.2012.11.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A resonance light-scattering method (RLS) for the determination of Rh(III) was initially developed, based on the reaction among Rh(III), WO42- and ethylrhodamine B. The method possesses high sensitivity, but lacks selectivity. Therefore, a Rh(III) ion-imprinted polymer (IIP), prepared by precipitation polymerization using 2-(allylthio)nicotinic acid (ANA) as functional monomer, was used as sorbent to construct a ion-imprint based solid-phase extraction (IIP-SPE) method for separation of rhodium from complicated matrices prior to its determination by RLS. The experimental parameters affecting the extraction efficiency and selectivity of IIP-SPE were studied carefully. Under the optimal conditions, the IIP-SPE column with the enrichment factor (EF) of 10 could be used at least 20 times without decreasing its extraction recovery (above 90%) significantly. The calibration graph for the determination of rhodium by RLS coupled with IIP-SPE procedure was linear in the range of 0.06-1.5 ng mL(-1) with the detection limit of 0.024 ng mL(-1). There is no metal ions tested at the concentration below 10 ng mL(-1) interfered in the determination of 0.8 ng mL(-1) Rh(III). The proposed IIP-SPE-RLS method was successfully applied to the extraction and measurement of trace rhodium in catalyst, water and geochemical samples with the relative standard deviation (RSD) of less than 4.0% (n=4). (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 36 条
[1]   Determination of rhodium: Since the origins until today ICP-OES and ICP-MS [J].
Bosch Ojeda, C. ;
Sanchez Rojas, F. .
TALANTA, 2007, 71 (01) :1-12
[2]   Solid phase selective separation and preconcentration of Cu(II) by Cu(II)-imprinted polyrnethacrylic microbeads [J].
Dakova, Ivanka ;
Karadjova, Irina ;
Ivanov, No ;
Georgieva, Ventsislava ;
Evtimova, Bisera ;
Georgiev, George .
ANALYTICA CHIMICA ACTA, 2007, 584 (01) :196-203
[3]   Preconcentrative separation of palladium(II) using palladium(II) ion-imprinted polymer particles formed with different quinoline derivatives and evaluation of binding parameters based on adsorption isotherm models [J].
Daniel, S ;
Babu, PEJ ;
Rao, TP .
TALANTA, 2005, 65 (02) :441-452
[4]   Investigation of different polymerization methods on the analytical performance of palladium(II) ion imprinted polymer materials [J].
Daniel, S ;
Rao, PP ;
Rao, TP .
ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) :197-206
[5]   Synthesis of imprinted polymer material with palladium ion nanopores and its analytical application [J].
Daniel, S ;
Gladis, JM ;
Rao, TP .
ANALYTICA CHIMICA ACTA, 2003, 488 (02) :173-182
[6]   Ternary ion-association complex based ion imprinted polymers (IIPs) for trace determination of palladium(II) in environmental samples [J].
Daniel, Sobhi ;
Praveen, R. S. ;
Rao, Talasila Prasada .
ANALYTICA CHIMICA ACTA, 2006, 570 (01) :79-87
[7]  
Fan H.T., 2009, CHEM B, V1, P10
[8]   Determination of platinum, palladium and rhodium in biological and environmental samples by low temperature electrothermal vaporization inductively coupled plasma atomic emission spectrometry with diethyldithiocarbamate as chemical modifier [J].
Fan, ZF ;
Jiang, ZC ;
Yang, F ;
Hu, B .
ANALYTICA CHIMICA ACTA, 2004, 510 (01) :45-51
[9]  
[冯立顺 FENG LiShun], 2011, [光谱实验室, Chinese Journal of Spectroscopy laboratory], V28, P1037
[10]   Flame atomic absorption spectrometry for the determination of trace amount of rhodium after separation and preconcentration onto modified multiwalled carbon nanotubes as a new solid sorbent [J].
Ghaseminezhad, S. ;
Aftali, D. ;
Taher, M. A. .
TALANTA, 2009, 80 (01) :168-172