A Multi-Axis Tactile Sensor Array for Touchscreen Applications

被引:3
|
作者
Yue, Shichao [1 ]
Qiu, Yang [1 ]
Moussa, Walied A. [1 ]
机构
[1] Univ Alberta, Mech Engn Dept, Edmonton, AB T6G 1H9, Canada
关键词
Tactile sensors array; piezoresistive devices; touchscreen; MEMS; FORCE SENSOR; TOUCH; SOFT;
D O I
10.1109/JMEMS.2017.2778572
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Touchscreens have been prevalent in daily life and ubiquitously applied in consuming electronics, industrial control systems, and other applications as human computer interfaces (HCIs), which offers a convenient way for the human to interact with the smart devices. However, the lack of tactile force feedback from these conventional touchscreens draws limitations on the dexterity and intuitiveness of those devices, which results in multi-level menus, waiting, multi-finger gestures, and so on. To enhance and diversify functions of touchscreens, this paper presents a multi-axis tactile sensor array prototype with a unique layered structure, which is capable of sensing both 3-directional tactile force and location information over an area of 60 mm x 60 mm by utilizing only 2 x 2 piezoresistive MEMS force sensors. This paper integrated the sensibility of tangential force and normal force within one system, which sheds light on multi-axis tactile applications and dramatically reduced the number of tactile cells. The sensor array design, fabrication and packaging, and test approaches have been discussed in this paper. Qualitative and quantitative analysis have been conducted to evaluate the performance of the tactile sensor array with tested force range of 0.1 similar to 0.5 N. The results demonstrated the functionality of proposed sensor array, which exhibited promising potential for touchscreen applications.
引用
收藏
页码:179 / 189
页数:11
相关论文
共 50 条
  • [21] A MULTI-AXIS PIEZORESISTIVE MEMS SENSOR FOR ACOUSTIC EMISSION
    Matsuda, Nobuhiko
    Dung, Nguyen Minh
    Takahata, Tomoyuki
    Shimoyama, Isao
    30TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2017), 2017, : 1181 - 1183
  • [22] Segmented binary control of multi-axis SMA array actuators
    Cho, KJ
    Selden, B
    Asada, HH
    SMART STRUCTURES AND MATERIALS 2005: MODELING, SIGNAL PROCESSING, AND CONTROL, 2005, 5757 : 314 - 322
  • [23] PIEZOELECTRIC/MAGNETOSTRICTIVE MEMS RESONANT SENSOR ARRAY FOR IN-PLANE MULTI-AXIS MAGNETIC FIELD DETECTION
    Kim, Hoe Joon
    Wang, Sibo
    Xu, Changting
    Laughlin, David
    Zhu, Jingxi
    Piazza, Gianluca
    30TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2017), 2017, : 109 - 112
  • [24] A high sensitivity, low cost and fully decoupled multi-axis capacitive tactile force sensor for robotic surgical systems
    Hussain, Sajid
    Saleem, Muhammad Mubasher
    Rehan, Muhammad
    Elahi, Hassan
    Tiwana, Mohsin Islam
    PLOS ONE, 2024, 19 (11):
  • [25] A high sensitivity and multi-axis fringing electric field based capacitive tactile force sensor for robot assisted surgery
    Arshad, Adeel
    Saleem, Muhammad Mubasher
    Tiwana, Mohsin Islam
    Rahman, Hamood Ur
    Iqbal, Sohail
    Cheung, Rebecca
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 354
  • [26] Design of a Motor Bracket Multi-Axis Force/Torque Sensor
    Chen, Chung-Sheng
    Lin, Thomas Chang-Hao
    Lin, Tzu-Han
    Lin, Pei-Chun
    2016 13TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2016, : 305 - 307
  • [27] Calibration method on machine for multi-axis heavy force sensor
    Liu, Wei
    Jia, Zhenyuan
    Li, Qi
    Sensors and Transducers, 2012, 142 (07): : 130 - 142
  • [28] Utilization of modal analysis in design of multi-axis force sensor
    Draisey, Sherry
    Richmond, Drew
    Proceedings of the International Modal Analysis Conference - IMAC, 2000, 2 : 1485 - 1490
  • [29] Three-Axis Contact Force Measurement of a Flexible Tactile Sensor Array for Hand Grasping Applications
    Wang, Yancheng
    Xi, Kailun
    Mei, Deqing
    Xin, Zhihao
    Chen, Zichen
    WEARABLE SENSORS AND ROBOTS, 2017, 399 : 67 - 79
  • [30] Utilization of modal analysis in design of multi-axis force sensor
    Draisey, S
    Richmond, D
    IMAC-XVIII: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, PROCEEDINGS, 2000, 4062 : 1485 - 1490