Performance of Multiplex Cytokine Assays in Serum and Saliva among Community-Dwelling Postmenopausal Women

被引:53
作者
Browne, Richard W. [1 ]
Kantarci, Alpdogan [2 ]
LaMonte, Michael J. [3 ]
Andrews, Christopher A. [4 ]
Hovey, Kathleen M. [3 ]
Falkner, Karen L. [3 ]
Cekici, Ali [2 ]
Stephens, Danielle [2 ]
Genco, Robert J. [5 ]
Scannapieco, Frank A. [5 ]
Van Dyke, Thomas E. [2 ]
Wactawski-Wende, Jean [3 ]
机构
[1] SUNY Buffalo, Dept Biotech & Clin Lab Sci, Buffalo, NY 14260 USA
[2] Forsyth Inst, Dept Periodontol, Boston, MA USA
[3] SUNY Buffalo, Dept Social & Prevent Med, New York, NY USA
[4] SUNY Buffalo, Dept Biostat, Buffalo, NY 14260 USA
[5] SUNY Buffalo, Dept Oral Biol, New York, NY USA
来源
PLOS ONE | 2013年 / 8卷 / 04期
关键词
INTERNAL QUALITY-CONTROL; BIOLOGICAL VARIATION; ELISA; VALIDATION; RULES; IDENTIFICATION; QUANTITATION; INFLAMMATION; IMMUNOASSAYS; TECHNOLOGY;
D O I
10.1371/journal.pone.0059498
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Multiplexing arrays increase the throughput and decrease sample requirements for studies employing multiple biomarkers. The goal of this project was to examine the performance of Multiplex arrays for measuring multiple protein biomarkers in saliva and serum. Specimens from the OsteoPerio ancillary study of the Women's Health Initiative Observational Study were used. Participants required the presence of at least 6 teeth and were excluded based on active cancer and certain bone issues but were not selected on any specific condition. Quality control (QC) samples were created from pooled serum and saliva. Twenty protein markers were measured on five multiplexing array panels. Sample pretreatment conditions were optimized for each panel. Recovery, lower limit of quantification (LLOQ) and imprecision were determined for each analyte. Statistical adjustment at the plate level was used to reduce imprecision estimates and increase the number of usable observations. Sample pre-treatment improved recovery estimates for many analytes. The LLOQ for each analyte agreed with manufacturer specifications except for MMP-1 and MMP-2 which were significantly higher than reported. Following batch adjustment, 17 of 20 biomarkers in serum and 9 of 20 biomarkers in saliva demonstrated acceptable precision, defined as <20% coefficient of variation (<25% at LLOQ). The percentage of cohort samples having levels within the reportable range for each analyte varied from 10% to 100%. The ratio of levels in saliva to serum varied from 1:100 to 28:1. Correlations between saliva and serum were of moderate positive magnitude and significant for CRP, MMP-2, insulin, adiponectin, GM-CSF and IL-5. Multiplex arrays exhibit high levels of analytical imprecision, particularly at the batch level. Careful sample pre-treatment can enhance recovery and reduce imprecision. Following statistical adjustments to reduce batch effects, we identified biomarkers that are of acceptable quality in serum and to a lesser degree in saliva using Multiplex arrays.
引用
收藏
页数:13
相关论文
共 38 条
  • [1] Clinical and community risk models of incident tooth loss in postmenopausal women from the Buffalo Osteo Perio Study
    Bole, Christopher
    Wactawski-Wende, Jean
    Hovey, Kathleen M.
    Genco, Robert J.
    Hausmann, Ernest
    [J]. COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 2010, 38 (06) : 487 - 497
  • [2] Bacterial species in subgingival plaque and oral bone loss in postmenopausal women
    Brennan, Renee M.
    Genco, Robert J.
    Wilding, Gregory E.
    Hovey, Kathleen M.
    Trevisan, Maurizio
    Wactawski-Wende, Jean
    [J]. JOURNAL OF PERIODONTOLOGY, 2007, 78 (06) : 1051 - 1061
  • [3] Browne RW, 2008, BIOMARKERS, V13, P160, DOI [10.1080/13547500701775563, 10.1080/13547500701775563 ]
  • [4] Procedures for Determination of Detection Limits Application to High-performance Liquid Chromatography Analysis of Fat-soluble Vitamins in Human Serum
    Browne, Richard W.
    Whitcomb, Brian W.
    [J]. EPIDEMIOLOGY, 2010, 21 : S4 - S9
  • [5] ANTI-BACTERIAL PEPTIDE FROM NORMAL RABBIT SERUM .1. ISOLATION FROM WHOLE SERUM, ACTIVITY, AND MICROBICIDAL SPECTRUM
    CARROLL, SF
    MARTINEZ, RJ
    [J]. BIOCHEMISTRY, 1981, 20 (21) : 5973 - 5981
  • [6] Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
    Carson, RT
    Vignali, DAA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) : 41 - 52
  • [7] Evaluation of Multiplexed Cytokine and Inflammation Marker Measurements: a Methodologic Study
    Chaturvedi, Anil K.
    Kemp, Troy J.
    Pfeiffer, Ruth M.
    Biancotto, Angelique
    Williams, Marcus
    Munuo, Stella
    Purdue, Mark P.
    Hsing, Ann W.
    Pinto, Ligia
    McCoy, J. Philip
    Hildesheim, Allan
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2011, 20 (09) : 1902 - 1911
  • [8] CHARACTERIZATION OF THE INTRACELLULAR PROCESSING AND SECRETION OF HEPATIC LIPASE IN FU5AH RAT HEPATOMA-CELLS
    CISAR, LA
    BENSADOUN, A
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1987, 927 (03) : 305 - 314
  • [9] Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic assessments of macromolecules
    DeSilva, B
    Smith, W
    Weiner, R
    Kelley, M
    Smolec, JM
    Lee, B
    Khan, M
    Tacey, R
    Hill, H
    Celniker, A
    [J]. PHARMACEUTICAL RESEARCH, 2003, 20 (11) : 1885 - 1900
  • [10] Salivary cortisol reflects serum cortisol: analysis of circadian profiles
    Dorn, Lorah D.
    Lucke, Joseph F.
    Loucks, Tammy L.
    Berga, Sarah L.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 281 - 284