Improving Fault Ride-Through Capability of DFIG-Based Wind Turbine Using Superconducting Fault Current Limiter

被引:100
作者
Elshiekh, Mariam E. [1 ]
Mansour, Diaa-Eldin A. [1 ]
Azmy, Ahmed M. [1 ]
机构
[1] Tanta Univ, Fac Engn, Dept Elect Power & Machines Engn, Tanta 31521, Egypt
关键词
Doubly fed induction generator (DFIG); fault ride-through (FRT) capability; superconducting fault current limiter (SFCL); wind turbine; FED INDUCTION GENERATOR; FARMS;
D O I
10.1109/TASC.2012.2235132
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With increased penetration of wind energy as a renewable energy source, there is a need to keep wind turbines connected to the grid during different disturbances such as grid faults. In this paper, the use of superconducting fault current limiter (SFCL) is proposed to reduce fault current level at the stator side and improve the fault ride-through (FRT) capability of the system. To highlight the proposed technique, a doubly fed induction generator (DFIG) is considered as a wind-turbine generator, where the whole system is simulated using PSCAD/EMTDC software. Detailed simulation results are obtained with and without SFCL considering stator and rotor currents. In addition, the voltage profile at the generator terminals is analyzed. The effect of limiting resistance value is also investigated. The obtained results ensure that the SFCL is effective in decreasing the fault current. Moreover, both the voltage dip at the generator terminals and the reactive power consumption from the grid are decreased during the fault. The voltage dip characteristics are discussed in accordance with international grid codes for wind turbines.
引用
收藏
页数:4
相关论文
共 14 条
[1]   Current-Time Characteristics of Resistive Superconducting Fault Current Limiters [J].
Blair, Steven M. ;
Booth, Campbell D. ;
Burt, Graeme M. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (02)
[2]   Coordinated reactive power control for facilitating fault ride through of doubly fed induction generator- and fixed speed induction generator-based wind farms [J].
Foster, S. ;
Xu, L. ;
Fox, B. .
IET RENEWABLE POWER GENERATION, 2010, 4 (02) :128-138
[3]  
Fox B., 2007, WIND POWER INTEGRATI
[4]   Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips [J].
Lopez, Jesus ;
Gubia, Eugenio ;
Olea, Eneko ;
Ruiz, Josu ;
Marroyo, Luis .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (10) :4246-4254
[5]   Decoupled-DFIG Fault Ride-Through Strategy for Enhanced Stability Performance During Grid Faults [J].
Meegahapola, Lasantha Gunaruwan ;
Littler, Tim ;
Flynn, Damian .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2010, 1 (03) :152-162
[6]   Modeling and Ride-Through Control of Doubly Fed Induction Generators During Symmetrical Voltage Sags [J].
Mendes, Victor Flores ;
de Sousa, Clodualdo Venicio ;
Silva, Selenio Rocha ;
Rabelo, Balduino Cezar, Jr. ;
Hofmann, Wilfried .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (04) :1161-1171
[7]   Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip [J].
Morren, J ;
de Haan, SWH .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :435-441
[8]   Thermal and electrical analysis of coated conductor under AC over-current [J].
Nam, Kwanwoo ;
Lee, Chanjoo ;
Park, Dong Keun ;
Ko, Tae Kuk ;
Seok, Bok-Yeol .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :1923-1926
[9]   Wind Farms Fault Ride Through Using DFIG With New Protection Scheme [J].
Okedu, Kenneth E. ;
Muyeen, S. M. ;
Takahashi, Rion ;
Tamura, Junji .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2012, 3 (02) :242-254
[10]   Analytical Study of Grid-Fault Response of Wind Turbine Doubly Fed Induction Generator [J].
Pannell, Graham ;
Atkinson, David J. ;
Zahawi, Bashar .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (04) :1081-1091