Anatomic localization of 24-and 96-h particle retention in canine airways

被引:44
作者
Kreyling, WG
Blanchard, JD
Godleski, JJ
Haeussermann, S
Heyder, J
Hutzler, P
Schulz, H
Sweeney, TD
Takenaka, S
Ziesenis, A
机构
[1] GSF, Inst Inhalat Biol, Natl Res Ctr Environm & Hlth, D-85758 Neuherberg, Munich, Germany
[2] GSF, Inst Pathol, Natl Res Ctr Environm & Hlth, D-85758 Neuherberg, Munich, Germany
[3] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
关键词
aerosol bolus inhalation; convective gas transport; particle distribution in lungs; slow particle clearance from airways; fluorescent or radiolabeled polystyrene particles;
D O I
10.1152/jappl.1999.87.1.269
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Anatomic localization of 24- and 96-h particle retention in canine airways. J. Appl. Physiol. 87(1): 269-284, 1999.-Long-term retention of particles in airways is controversial. However, precise anatomic localization of the particles is not possible in people. In this study the anatomic location of retained particles after shallow bolus inhalation was determined in anesthetized, ventilated beagle dogs. Fifty 30-cm(3) boluses containing monodisperse 2.5-mu m polystyrene particles (PSL) were delivered to a shallow lung depth of 81-129 cm(3). At 96 h before euthanasia, red fluorescent PSL were used; at 24 h, green fluorescent PSL and Tc-99m-labeled PSL were used. Clearance of Tc-99m-PSL was measured during the next 24 h. Sites of particle retention were determined in systematic, volume-weighted random samples of microwave-fixed lung tissue. Precise particle localization and distribution was analyzed by using gamma counting, conventional fluorescence microscopy, and confocal microscopy. Within 24 h after shallow bolus inhalation, 50-95% of the deposited Tc-99m-PSL were cleared, but the remaining fraction was cleared slowly in all dogs, similar to previous human results. The three-dimensional deposition patterns showed particles across the entire cross-sectional plane of the lungs at the level of the carina. In these locations, 33+/-9.9%; of the retained particles were found in small, nonrespiratory airways (0.3- to 1-mm diameter) and 49 +/- 10% of the particles in alveoli; the remaining fraction was found in larger airways. After 96 h, a similar pattern was found. These findings suggest that long-term retention in airways is at the bronchiolar level.
引用
收藏
页码:269 / 284
页数:16
相关论文
共 73 条
  • [1] ALBERT R E, 1955, AMA Arch Ind Health, V12, P99
  • [2] INTRAPULMONARY MIXING OF GASES STUDIED WITH AEROSOLS
    ALTSHULER, B
    PALMES, ED
    YARMUS, L
    NELSON, N
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (03) : 321 - 327
  • [3] HUMAN DEPOSITION AND CLEARANCE OF 6-MU-M PARTICLES INHALED WITH AN EXTREMELY LOW-FLOW RATE
    ANDERSON, M
    PHILIPSON, K
    SVARTENGREN, M
    CAMNER, P
    [J]. EXPERIMENTAL LUNG RESEARCH, 1995, 21 (01) : 187 - 195
  • [4] [Anonymous], 1966, HEALTH PHYS, V12, P173
  • [5] BAIR WJ, 1994, ANN ICRP, V66, P24
  • [6] Bronchial airway deposition and retention of particles in inhaled boluses: effect of anatomic dead space
    Bennett, WD
    Scheuch, G
    Zeman, KL
    Brown, JS
    Kim, C
    Heyder, J
    Stahlhofen, W
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (02) : 685 - 694
  • [7] EFFECT OF POSTURE ON SINGLE-BREATH OXYGEN TEST IN NORMAL SUBJECTS
    CORTESE, DA
    RODARTE, JR
    REHDER, K
    HYATT, RE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (04) : 474 - 479
  • [8] Cuddihy RG, 1988, INHAL TOXICOL, P169
  • [9] DEVRIES WR, 1982, B EUR PHYSIOPATH RES, V18, P215
  • [10] Clearance of particles from small ciliated airways
    Falk, R
    Philipson, K
    Svartengren, M
    Jarvis, N
    Bailey, M
    Camner, P
    [J]. EXPERIMENTAL LUNG RESEARCH, 1997, 23 (06) : 495 - 515