Efficacy and Safety of Femtosecond Laser-Assisted Cataract Surgery Compared with Manual Cataract Surgery A Meta-Analysis of 14 567 Eyes

被引:135
作者
Popovic, Marko [1 ]
Campos-Moller, Xavier [2 ,3 ]
Schlenker, Matthew B. [2 ,3 ]
Ahmed, Iqbal Ike K. [2 ,3 ,4 ]
机构
[1] Univ Toronto, Fac Med, Toronto, ON, Canada
[2] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
[3] Prism Eye Inst, 3200 Erin Mills Pkwy,Unit 1, Mississauga, ON L5L 1W8, Canada
[4] Trillium Hlth Partners, Dept Ophthalmol, Mississauga, ON, Canada
关键词
EFFECTIVE PHACOEMULSIFICATION TIME; ENDOTHELIAL-CELL LOSS; OPTICAL COHERENCE TOMOGRAPHY; ANTERIOR CAPSULOTOMY; LENS FRAGMENTATION; STANDARD PHACOEMULSIFICATION; OUTCOMES; CAPSULORRHEXIS; DECENTRATION; SYSTEM;
D O I
10.1016/j.ophtha.2016.07.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Topic: To investigate the efficacy and safety of femtosecond laser-assisted cataract surgery (FLACS) relative to manual cataract surgery (MCS). Methods: A literature search of MEDLINE, EMBASE, and Scopus from 2007 to March 2016 was conducted. Studies containing both FLACS and MCS arms that reported on relevant efficacy and/or safety parameters were included. Weighted mean differences (WMDs) and risk ratios (RRs) with 95% confidence intervals (CIs) were calculated. Results: From 2802 screened articles, 14 567 eyes from 15 randomized controlled trials and 22 observational cohort studies were included. For primary visual and refractive outcomes, no statistically significant difference was detected between FLACS and MCS in uncorrected distance visual acuity (WMD, -0.02; 95% CI, -0.04 to 0.01; P = 0.19), corrected distance visual acuity (WMD, - 0.01; 95% CI, -0.02 to 0.01; P = 0.26), and mean absolute error (WMD, -0.02; 95% CI, -0.07 to 0.04; P = 0.57). In terms of secondary surgical end points, there was a statistically significant difference in favor of FLACS over MCS for effective phacoemulsification time (WMD, -3.03; 95% CI, -3.80 to -2.25; P < 0.001), capsulotomy circularity (WMD, 0.16; 95% CI, 0.11-0.21; P < 0.001), postoperative central corneal thickness (WMD, -6.37; 95% CI, -11.88 to - 0.86; P = 0.02), and corneal endothelial cell reduction (WMD, -55.43; 95% CI, -95.18 to -15.69; P = 0.006). There was no statistically significant difference between FLACS and MCS for total surgery time (WMD, 1.25; 95% CI, -0.08 to 2.59; P = 0.07), capsulotomy circularity using a second formula (WMD, 0.05; 95% CI, -0.01 to 0.12; P = 0.10), and corneal endothelial cell count (WMD, 73.39; 95% CI, -6.28 to 153.07; P = 0.07). As well, there was a significantly higher concentration of prostaglandins after FLACS relative to MCS (WMD, 198.34; 95% CI, 129.99-266.69; P < 0.001). Analysis of safety parameters revealed that there were no statistically significant differences in the incidence of overall complications between FLACS and MCS (RR, 2.15; 95% CI, 0.74 to 6.23; P = 0.16); however, posterior capsular tears were significantly more common in FLACS versus MCS (RR, 3.73; 95% CI, 1.50-9.25; P = 0.005). Conclusions: There were no statistically significant differences detected between FLACS and MCS in terms of patient-important visual and refractive outcomes and overall complications. Although FLACS did show a statistically significant difference for several secondary surgical outcomes, it was associated with higher prostaglandin concentrations and higher rates of posterior capsular tears. (C) 2016 by the American Academy of Ophthalmology.
引用
收藏
页码:2113 / 2126
页数:14
相关论文
共 78 条
  • [41] Corneal endothelial cell changes 5 years after laser in situ keratomileusis: Femtosecond laser versus mechanical microkeratome
    Klingler, Kyle N.
    McLaren, Jay W.
    Bourne, William M.
    Patel, Sanjay V.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) : 2125 - 2130
  • [42] KORYNTA J, 1994, J REFRACT CORNEAL S, V10, P556
  • [43] Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser-created Continuous Circular Capsulotomy
    Kranitz, Kinga
    Mihaltz, Kata
    Sandor, Gabor L.
    Takacs, Agnes
    Knorz, Michael C.
    Nagy, Zoltan Z.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) : 259 - 263
  • [44] Femtosecond Laser Capsulotomy and Manual Continuous Curvilinear Capsulorrhexis Parameters and Their Effects on Intraocular Lens Centration
    Kranitz, Kinga
    Takacs, Agnes
    Mihaltz, Kata
    Kovacs, Illes
    Knorz, Michael C.
    Nagy, Zoltan Z.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) : 558 - 563
  • [45] Endothelial cell loss and refractive predictability in femtosecond laser-assisted cataract surgery compared with conventional cataract surgery
    Krarup, Therese
    Holm, Lars Morten
    la Cour, Morten
    Kjaerbo, Hadi
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92 (07) : 617 - 622
  • [46] Interface corneal stromal irregularities after flap creation using femtosecond laser
    Kymionis, George D.
    Kounis, George A.
    Grentzelos, Michael A.
    Panagopoulou, Sophia I.
    Kandarakis, Stylianos A.
    Krasia, Maria S.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 207 - 209
  • [47] Outcomes of Femtosecond Laser Cataract Surgery With a Diffractive Multifocal Intraocular Lens
    Lawless, Michael
    Bali, Shveta Jindal
    Hodge, Chris
    Roberts, Timothy V.
    Chan, Colin
    Sutton, Gerard
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) : 859 - 864
  • [48] LIU T, 2014, BIOMED RES INT, V2014, DOI DOI 10.1155/2014/731565
  • [49] New technique to demonstrate corneal magnification using trypan blue in cataract surgery
    Marques, Frederico F.
    Marques, Daniela M. V.
    Osher, Robert H.
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2011, 70 (04) : 235 - 237
  • [50] Optical coherence tomography and 3-dimensional confocal structured imaging system-guided femtosecond laser capsulotomy versus manual continuous curvilinear capsulorhexis
    Mastropasqua, Leonardo
    Toto, Lisa
    Mattei, Peter A.
    Vecchiarino, Luca
    Mastropasqua, Alessandra
    Navarra, Riccardo
    Di Nicola, Marta
    Nubile, Mario
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) : 2035 - 2043