Development of new calibration standard for non-contact tonometers

被引:0
|
作者
Pavlasek, Peter [1 ,2 ]
Chytil, Miroslav [1 ]
Rybar, Jan [2 ]
Palencar, Jakub [2 ]
Duris, Stanislav [2 ]
Pavlasek, Peter [1 ,2 ]
机构
[1] Slovak Inst Metrol, Dep Thermometry, Bratislava, Slovakia
[2] Slovak Univ Technol Bratislava, Fac Mech Engn, Bratislava, Slovakia
来源
2018 11TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2018) | 2018年
关键词
glaucoma; tonometry; IOP measurements; non-contact; calibration; standard;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper deals with the problematic of eye tonometer measurements, more specifically the missing universal, independent standard for their routine checks and calibration. The paper furthermore presents the principles and initial results of newly developed standard that has the potential to be used for any non-contact eye tonometer device. The initial test measurements have shown a consistency of the generated pressure with increased divergence measured by tow selected contact and non-contact tonometers.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Influence of keratometry and refraction on the agreement among Goldmann, non-contact and Tono-Pen tonometers.
    Paranhos, AJR
    Prata, JAJR
    Omi, CA
    Paranhos, FRL
    Freitas, D
    Mello, PAA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4919 - 4919
  • [32] STANDARD NON-CONTACT BURN IMMEDIATE CONTRACTION OF BURNED SKIN
    MOSEROVA, J
    BEHOUNKOVA, E
    ACTA CHIRURGIAE PLASTICAE, 1976, 18 (03): : 152 - 160
  • [33] Discussion on current waveform in non-contact electrostatic discharge standard
    Wang Chengzhuo
    Ruan Fangming
    Zhu Sha
    2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC-BEIJING), 2017,
  • [34] Letter to the Editor: New Aspects in the Calibration of Tonometers
    Stodtmeister, R.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (08) : 997 - 999
  • [35] A new non-contact corneal aesthesiometer (NCCA)
    Murphy, PJ
    Patel, S
    Marshall, J
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1996, 16 (02) : 101 - 107
  • [36] Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects
    Bang, Seung Pil
    Lee, Chong Eun
    Kim, Yu Cheol
    BMC OPHTHALMOLOGY, 2017, 17
  • [37] Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects
    Seung Pil Bang
    Chong Eun Lee
    Yu Cheol Kim
    BMC Ophthalmology, 17
  • [38] The new generation of non-contact drying solution
    不详
    WOCHENBLATT FUR PAPIERFABRIKATION, 2004, 132 (13): : 814 - 814
  • [39] New method for non-contact material testing
    Adhaesion Kleben und Dichten, 2019, 63 (09): : 38 - 41
  • [40] New system of non-contact pose measurement
    Sun, Xian-Kui
    Qin, Lan
    Guangdian Gongcheng/Opto-Electronic Engineering, 2007, 34 (01): : 50 - 54