Dual-energy CT and its potential use for quantitative myocardial CT perfusion

被引:48
作者
So, Aaron [1 ,2 ]
Hsieh, Jiang [3 ]
Narayanan, Suresh [3 ]
Thibault, Jean-Baptiste [3 ]
Imai, Yasuhiro [3 ]
Dutta, Sandeep [3 ]
Leipsic, Jonathon [4 ]
Min, James [5 ,6 ]
LaBounty, Troy [5 ,6 ]
Lee, Ting-Yim [1 ,2 ]
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, Imaging Program, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] Univ British Columbia, Dept Radiol & Med, Vancouver, BC V5Z 1M9, Canada
[5] Cedars Sinai Heart Inst, Inst Heart, Dept Med, Los Angeles, CA USA
[6] Cedars Sinai Heart Inst, Inst Heart, Dept Imaging, Los Angeles, CA USA
基金
加拿大健康研究院;
关键词
Dual-energy CT; Beam hardening correction; Myocardial CT perfusion; Quantitative imaging; Rapid tube potential switching; COMPUTED TOMOGRAPHIC APPARATUS; X-RAY CT; IMAGE QUALITY; QUANTIFICATION; DETECTORS; MODEL; RECONSTRUCTION; EXPERIENCE; SCATTER;
D O I
10.1016/j.jcct.2012.07.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Application of quantitative myocardial CT perfusion (CTP) for the assessment of coronary artery disease may have a significant effect on patient care as the functional significance of a coronary stenosis can be evaluated through absolute measurement of the downstream myocardial perfusion (MP) both at rest and under exercise or pharmacologic stress. A main challenge of myocardial CTP is beam hardening (BH), arising from the polychromatic nature of x-rays used in CT scanning and the presence of highly attenuating contrast agent in the heart chambers during the CT acquisition. The BH effect induces significant nonuniform shifts in CT numbers which, if uncorrected, can lead to inaccurate assessment of MP. With the recent developments of dual-energy CT (DECT) scanning on clinical scanners, the BH effect on MP measurement could be reduced with the generation of monochromatic images relatively free of BH artifacts from the acquired dual-energy data. Here, we review the different techniques of acquiring dual-energy scans and generating monochromatic images, followed by discussion on the progress of developing a DECT technique with reduced radiation dose for quantitative myocardial CTP. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:308 / 317
页数:10
相关论文
共 34 条
  • [1] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [2] Barreto Mitya, 2008, J Cardiovasc Comput Tomogr, V2, P234, DOI 10.1016/j.jcct.2008.05.146
  • [3] Adenosine-Stress Dynamic Myocardial CT Perfusion Imaging Initial Clinical Experience
    Bastarrika, Gorka
    Ramos-Duran, Luis
    Rosenblum, Michael A.
    Kang, Doo Kyoung
    Rowe, Garrett W.
    Schoepf, U. Joseph
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 306 - 313
  • [4] Dual-Energy CT for the Assessment of Chronic Myocardial Infarction in Patients With Chronic Coronary Artery Disease: Comparison With 3-T MRI
    Bauer, Ralf W.
    Kerl, J. Matthias
    Fischer, Nadine
    Burkhard, Thorsten
    Larson, Maya C.
    Ackermann, Hanns
    Vogl, Thomas J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 639 - 646
  • [5] Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study
    Bornefalk, Hans
    Danielsson, Mats
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) : 1999 - 2022
  • [6] BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY
    BROOKS, RA
    DICHIRO, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) : 390 - 398
  • [7] QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING
    BROOKS, RA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) : 487 - 493
  • [8] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [9] Image reconstruction and image quality evaluation for a dual source CT scanner
    Flohr, T. G.
    Bruder, H.
    Stierstorfer, K.
    Petersilka, M.
    Schmidt, B.
    McCollough, C. H.
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5882 - 5897
  • [10] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268