Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation

被引:36
作者
Bittner, Daniel O. [1 ,2 ]
Arnold, Martin [1 ]
Klinghammer, Lutz [1 ]
Schuhbaeck, Annika [1 ]
Hell, Michaela M. [1 ]
Muschiol, Gerd [1 ]
Gauss, Soeren [1 ]
Lell, Michael [3 ]
Uder, Michael [3 ]
Hoffmann, Udo [2 ]
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Internal Med Cardiol 2, Ulmenweg 18, D-91054 Erlangen, Germany
[2] Harvard Med Sch, Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02115 USA
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
关键词
Heart valve prosthesis implantation; Transcatheter aortic valve implantation (TAVI); Low contrast agent; Computed tomography; Aortography; PROSPECTIVE RANDOMIZED-TRIAL; EXPERT CONSENSUS DOCUMENT; CT CORONARY-ANGIOGRAPHY; REDUCED IODINE LOAD; REPLACEMENT; NEPHROPATHY; OUTCOMES; DISEASE; ACCURACY; STENOSIS;
D O I
10.1007/s00330-016-4320-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 +/- 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 +/- 60 HU/1.5 at the aortic annulus compared to 289 +/- 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 +/- 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. aEuro cent Reduction of contrast agent volume is crucial in patients with chronic renal failure. aEuro cent Novel third-generation computed tomography helps to reduce contrast agent volume. aEuro cent Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. aEuro cent A low-contrast CT protocol is feasible for pre-procedural TAVI planning.
引用
收藏
页码:4497 / 4504
页数:8
相关论文
共 28 条
  • [21] Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System
    Meyer, Mathias
    Haubenreisser, Holger
    Schoepf, U. Joseph
    Vliegenthart, Rozemarijn
    Leidecker, Christianne
    Allmendinger, Thomas
    Lehmann, Ralf
    Sudarski, Sonja
    Borggrefe, Martin
    Schoenberg, Stefan O.
    Henzler, Thomas
    [J]. RADIOLOGY, 2014, 273 (02) : 373 - 382
  • [22] Long-Term Outcomes After Transcatheter Aortic Valve Implantation in High-Risk Patients With Severe Aortic Stenosis The UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry
    Moat, Neil E.
    Ludman, Peter
    de Belder, Mark A.
    Bridgewater, Ben
    Cunningham, Andrew D.
    Young, Christopher P.
    Thomas, Martyn
    Kovac, Jan
    Spyt, Tom
    MacCarthy, Philip A.
    Wendler, Olaf
    Hildick-Smith, David
    Davies, Simon W.
    Trivedi, Uday
    Blackman, Daniel J.
    Levy, Richard D.
    Brecker, Stephen J. D.
    Baumbach, Andreas
    Daniel, Tim
    Gray, Huon
    Mullen, Michael J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : 2130 - 2138
  • [23] Reduced iodine load with CT coronary angiography using dual-energy imaging: A prospective randomized trial compared with standard coronary CT angiography
    Raju, Rekha
    Thompson, Angus G.
    Lee, Kristy
    Precious, Bruce
    Yang, Tae-Hyun
    Berger, Adam
    Taylor, Carolyn
    Heilbron, Brett
    Nguyen, Giang
    Earls, James
    Min, James
    Carrascosa, Patricia
    Murphy, Darra
    Hague, Cameron
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) : 282 - 288
  • [24] Reproducibility of aortic annulus measurements by computed tomography
    Schuhbaeck, Annika
    Achenbach, Stephan
    Pflederer, Tobias
    Marwan, Mohamed
    Schmid, Jasmin
    Nef, Holger
    Rixe, Johannes
    Hecker, Franziska
    Schneider, Christian
    Lell, Michael
    Uder, Michael
    Arnold, Martin
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (08) : 1878 - 1888
  • [25] LEFT RETROGRADE CARDIOANGIOGRAPHY IN ACQUIRED CARDIAC DISEASE - TECHNIC INDICATIONS + INTERPRETATIONS IN 700 CASES
    SELLERS, RD
    AMPLATZ, K
    LEVY, MJ
    LILLEHEI, CW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1964, 14 (04) : 437 - &
  • [26] Accuracy of aortic annular measurements obtained from three-dimensional echocardiography, CT and MRI: human in vitro and in vivo studies
    Tsang, Wendy
    Bateman, Michael G.
    Weinert, Lynn
    Pellegrini, Gian
    Mor-Avi, Victor
    Sugeng, Lissa
    Yeung, Hubert
    Patel, Amit R.
    Hill, Alexander J.
    Iaizzo, Paul A.
    Lang, Roberto M.
    [J]. HEART, 2012, 98 (15) : 1146 - 1152
  • [27] Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode
    Wuest, W.
    Anders, K.
    Schuhbaeck, A.
    May, M. S.
    Gauss, S.
    Marwan, M.
    Arnold, M.
    Ensminger, S.
    Muschiol, G.
    Daniel, W. G.
    Uder, M.
    Achenbach, S.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (01) : 51 - 58
  • [28] Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography-A Prospective Randomized Trial
    Yuan, Ren
    Shuman, William P.
    Earls, James P.
    Hague, Cameron J.
    Mumtaz, Hina A.
    Scott-Moncrieff, Andrew
    Elli, Jennifer D.
    Mayo, John R.
    Leipsic, Jonathon A.
    [J]. RADIOLOGY, 2012, 262 (01) : 290 - 297