Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation

被引:38
作者
Bittner, Daniel O. [1 ,2 ]
Arnold, Martin [1 ]
Klinghammer, Lutz [1 ]
Schuhbaeck, Annika [1 ]
Hell, Michaela M. [1 ]
Muschiol, Gerd [1 ]
Gauss, Soeren [1 ]
Lell, Michael [3 ]
Uder, Michael [3 ]
Hoffmann, Udo [2 ]
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Internal Med Cardiol 2, Ulmenweg 18, D-91054 Erlangen, Germany
[2] Harvard Med Sch, Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02115 USA
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
关键词
Heart valve prosthesis implantation; Transcatheter aortic valve implantation (TAVI); Low contrast agent; Computed tomography; Aortography; PROSPECTIVE RANDOMIZED-TRIAL; EXPERT CONSENSUS DOCUMENT; CT CORONARY-ANGIOGRAPHY; REDUCED IODINE LOAD; REPLACEMENT; NEPHROPATHY; OUTCOMES; DISEASE; ACCURACY; STENOSIS;
D O I
10.1007/s00330-016-4320-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 +/- 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 +/- 60 HU/1.5 at the aortic annulus compared to 289 +/- 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 +/- 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. aEuro cent Reduction of contrast agent volume is crucial in patients with chronic renal failure. aEuro cent Novel third-generation computed tomography helps to reduce contrast agent volume. aEuro cent Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. aEuro cent A low-contrast CT protocol is feasible for pre-procedural TAVI planning.
引用
收藏
页码:4497 / 4504
页数:8
相关论文
共 28 条
[21]   Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System [J].
Meyer, Mathias ;
Haubenreisser, Holger ;
Schoepf, U. Joseph ;
Vliegenthart, Rozemarijn ;
Leidecker, Christianne ;
Allmendinger, Thomas ;
Lehmann, Ralf ;
Sudarski, Sonja ;
Borggrefe, Martin ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
RADIOLOGY, 2014, 273 (02) :373-382
[22]   Long-Term Outcomes After Transcatheter Aortic Valve Implantation in High-Risk Patients With Severe Aortic Stenosis The UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry [J].
Moat, Neil E. ;
Ludman, Peter ;
de Belder, Mark A. ;
Bridgewater, Ben ;
Cunningham, Andrew D. ;
Young, Christopher P. ;
Thomas, Martyn ;
Kovac, Jan ;
Spyt, Tom ;
MacCarthy, Philip A. ;
Wendler, Olaf ;
Hildick-Smith, David ;
Davies, Simon W. ;
Trivedi, Uday ;
Blackman, Daniel J. ;
Levy, Richard D. ;
Brecker, Stephen J. D. ;
Baumbach, Andreas ;
Daniel, Tim ;
Gray, Huon ;
Mullen, Michael J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) :2130-2138
[23]   Reduced iodine load with CT coronary angiography using dual-energy imaging: A prospective randomized trial compared with standard coronary CT angiography [J].
Raju, Rekha ;
Thompson, Angus G. ;
Lee, Kristy ;
Precious, Bruce ;
Yang, Tae-Hyun ;
Berger, Adam ;
Taylor, Carolyn ;
Heilbron, Brett ;
Nguyen, Giang ;
Earls, James ;
Min, James ;
Carrascosa, Patricia ;
Murphy, Darra ;
Hague, Cameron ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) :282-288
[24]   Reproducibility of aortic annulus measurements by computed tomography [J].
Schuhbaeck, Annika ;
Achenbach, Stephan ;
Pflederer, Tobias ;
Marwan, Mohamed ;
Schmid, Jasmin ;
Nef, Holger ;
Rixe, Johannes ;
Hecker, Franziska ;
Schneider, Christian ;
Lell, Michael ;
Uder, Michael ;
Arnold, Martin .
EUROPEAN RADIOLOGY, 2014, 24 (08) :1878-1888
[25]   LEFT RETROGRADE CARDIOANGIOGRAPHY IN ACQUIRED CARDIAC DISEASE - TECHNIC INDICATIONS + INTERPRETATIONS IN 700 CASES [J].
SELLERS, RD ;
AMPLATZ, K ;
LEVY, MJ ;
LILLEHEI, CW .
AMERICAN JOURNAL OF CARDIOLOGY, 1964, 14 (04) :437-&
[26]   Accuracy of aortic annular measurements obtained from three-dimensional echocardiography, CT and MRI: human in vitro and in vivo studies [J].
Tsang, Wendy ;
Bateman, Michael G. ;
Weinert, Lynn ;
Pellegrini, Gian ;
Mor-Avi, Victor ;
Sugeng, Lissa ;
Yeung, Hubert ;
Patel, Amit R. ;
Hill, Alexander J. ;
Iaizzo, Paul A. ;
Lang, Roberto M. .
HEART, 2012, 98 (15) :1146-1152
[27]   Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode [J].
Wuest, W. ;
Anders, K. ;
Schuhbaeck, A. ;
May, M. S. ;
Gauss, S. ;
Marwan, M. ;
Arnold, M. ;
Ensminger, S. ;
Muschiol, G. ;
Daniel, W. G. ;
Uder, M. ;
Achenbach, S. .
EUROPEAN RADIOLOGY, 2012, 22 (01) :51-58
[28]   Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography-A Prospective Randomized Trial [J].
Yuan, Ren ;
Shuman, William P. ;
Earls, James P. ;
Hague, Cameron J. ;
Mumtaz, Hina A. ;
Scott-Moncrieff, Andrew ;
Elli, Jennifer D. ;
Mayo, John R. ;
Leipsic, Jonathon A. .
RADIOLOGY, 2012, 262 (01) :290-297