Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation

被引:38
作者
Bittner, Daniel O. [1 ,2 ]
Arnold, Martin [1 ]
Klinghammer, Lutz [1 ]
Schuhbaeck, Annika [1 ]
Hell, Michaela M. [1 ]
Muschiol, Gerd [1 ]
Gauss, Soeren [1 ]
Lell, Michael [3 ]
Uder, Michael [3 ]
Hoffmann, Udo [2 ]
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Internal Med Cardiol 2, Ulmenweg 18, D-91054 Erlangen, Germany
[2] Harvard Med Sch, Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02115 USA
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
关键词
Heart valve prosthesis implantation; Transcatheter aortic valve implantation (TAVI); Low contrast agent; Computed tomography; Aortography; PROSPECTIVE RANDOMIZED-TRIAL; EXPERT CONSENSUS DOCUMENT; CT CORONARY-ANGIOGRAPHY; REDUCED IODINE LOAD; REPLACEMENT; NEPHROPATHY; OUTCOMES; DISEASE; ACCURACY; STENOSIS;
D O I
10.1007/s00330-016-4320-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 +/- 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 +/- 60 HU/1.5 at the aortic annulus compared to 289 +/- 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 +/- 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. aEuro cent Reduction of contrast agent volume is crucial in patients with chronic renal failure. aEuro cent Novel third-generation computed tomography helps to reduce contrast agent volume. aEuro cent Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. aEuro cent A low-contrast CT protocol is feasible for pre-procedural TAVI planning.
引用
收藏
页码:4497 / 4504
页数:8
相关论文
共 28 条
[1]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[2]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[3]  
Altman D. G., 1990, Practical Statistics for medical research, DOI DOI 10.1201/9780429258589
[4]   Predictors of Poor Outcomes After Transcatheter Aortic Valve Replacement Results From the PARTNER (Placement of Aortic Transcatheter Valve) Trial [J].
Arnold, Suzanne V. ;
Reynolds, Matthew R. ;
Lei, Yang ;
Magnuson, Elizabeth A. ;
Kirtane, Ajay J. ;
Kodali, Susheel K. ;
Zajarias, Alan ;
Thourani, Vinod H. ;
Green, Philip ;
Rodes-Cabau, Josep ;
Beohar, Nirat ;
Mack, Michael J. ;
Leon, Martin B. ;
Cohen, David J. .
CIRCULATION, 2014, 129 (25) :2682-2690
[5]   Ultra-Low Contrast Computed Tomographic Angiography (CTA) With 20-mL Total Dose for Transcatheter Aortic Valve Implantation (TAVI) Planning [J].
Azzalini, Lorenzo ;
Abbara, Suhny ;
Ghoshhajra, Brian B. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) :105-109
[6]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[7]   DOSING OF CONTRAST MATERIAL TO PREVENT CONTRAST NEPHROPATHY IN PATIENTS WITH RENAL-DISEASE [J].
CIGARROA, RG ;
LANGE, RA ;
WILLIAMS, RH ;
HILLIS, LD .
AMERICAN JOURNAL OF MEDICINE, 1989, 86 (06) :649-652
[8]   The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency [J].
Gruberg, L ;
Mintz, GS ;
Mehran, R ;
Dangas, G ;
Lansky, AJ ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (05) :1542-1548
[9]   2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement [J].
Holmes, David R., Jr. ;
Mack, Michael J. ;
Kaul, Sanjay ;
Agnihotri, Arvind ;
Alexander, Karen P. ;
Bailey, Steven R. ;
Calhoon, John H. ;
Carabello, Blase A. ;
Desai, Milind Y. ;
Edwards, Fred H. ;
Francis, Gary S. ;
Gardner, Timothy J. ;
Kappetein, A. Pieter ;
Linderbaum, Jane A. ;
Mukherjee, Chirojit ;
Mukherjee, Debabrata ;
Otto, Catherine M. ;
Ruiz, Carlos E. ;
Sacco, Ralph L. ;
Smith, Donnette ;
Thomas, James D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) :1200-1254
[10]   A prospective survey of patients with valvular heart disease in Europe:: The Euro Heart Survey on Valvular Heart Disease [J].
Iung, B ;
Baron, G ;
Butchart, EG ;
Delahaye, F ;
Gohlke-Bärwolf, C ;
Levang, OW ;
Tornos, P ;
Vanoverschelde, JL ;
Vermeer, F ;
Boersma, E ;
Ravaud, P ;
Vahanian, A .
EUROPEAN HEART JOURNAL, 2003, 24 (13) :1231-1243