Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation

被引:36
作者
Bittner, Daniel O. [1 ,2 ]
Arnold, Martin [1 ]
Klinghammer, Lutz [1 ]
Schuhbaeck, Annika [1 ]
Hell, Michaela M. [1 ]
Muschiol, Gerd [1 ]
Gauss, Soeren [1 ]
Lell, Michael [3 ]
Uder, Michael [3 ]
Hoffmann, Udo [2 ]
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Internal Med Cardiol 2, Ulmenweg 18, D-91054 Erlangen, Germany
[2] Harvard Med Sch, Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02115 USA
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
关键词
Heart valve prosthesis implantation; Transcatheter aortic valve implantation (TAVI); Low contrast agent; Computed tomography; Aortography; PROSPECTIVE RANDOMIZED-TRIAL; EXPERT CONSENSUS DOCUMENT; CT CORONARY-ANGIOGRAPHY; REDUCED IODINE LOAD; REPLACEMENT; NEPHROPATHY; OUTCOMES; DISEASE; ACCURACY; STENOSIS;
D O I
10.1007/s00330-016-4320-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 +/- 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 +/- 60 HU/1.5 at the aortic annulus compared to 289 +/- 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 +/- 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. aEuro cent Reduction of contrast agent volume is crucial in patients with chronic renal failure. aEuro cent Novel third-generation computed tomography helps to reduce contrast agent volume. aEuro cent Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. aEuro cent A low-contrast CT protocol is feasible for pre-procedural TAVI planning.
引用
收藏
页码:4497 / 4504
页数:8
相关论文
共 28 条
  • [1] Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
  • [2] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [3] Altman D. G., 1990, Practical Statistics for medical research, DOI DOI 10.1201/9780429258589
  • [4] Predictors of Poor Outcomes After Transcatheter Aortic Valve Replacement Results From the PARTNER (Placement of Aortic Transcatheter Valve) Trial
    Arnold, Suzanne V.
    Reynolds, Matthew R.
    Lei, Yang
    Magnuson, Elizabeth A.
    Kirtane, Ajay J.
    Kodali, Susheel K.
    Zajarias, Alan
    Thourani, Vinod H.
    Green, Philip
    Rodes-Cabau, Josep
    Beohar, Nirat
    Mack, Michael J.
    Leon, Martin B.
    Cohen, David J.
    [J]. CIRCULATION, 2014, 129 (25) : 2682 - 2690
  • [5] Ultra-Low Contrast Computed Tomographic Angiography (CTA) With 20-mL Total Dose for Transcatheter Aortic Valve Implantation (TAVI) Planning
    Azzalini, Lorenzo
    Abbara, Suhny
    Ghoshhajra, Brian B.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 105 - 109
  • [6] Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique
    Cademartiri, F
    Nieman, K
    van der Lugt, A
    Raaijmakers, RH
    Mollet, N
    Pattynama, PMT
    de Feyter, PJ
    Krestin, GP
    [J]. RADIOLOGY, 2004, 233 (03) : 817 - 823
  • [7] DOSING OF CONTRAST MATERIAL TO PREVENT CONTRAST NEPHROPATHY IN PATIENTS WITH RENAL-DISEASE
    CIGARROA, RG
    LANGE, RA
    WILLIAMS, RH
    HILLIS, LD
    [J]. AMERICAN JOURNAL OF MEDICINE, 1989, 86 (06) : 649 - 652
  • [8] The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency
    Gruberg, L
    Mintz, GS
    Mehran, R
    Dangas, G
    Lansky, AJ
    Kent, KM
    Pichard, AD
    Satler, LF
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (05) : 1542 - 1548
  • [9] 2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
    Holmes, David R., Jr.
    Mack, Michael J.
    Kaul, Sanjay
    Agnihotri, Arvind
    Alexander, Karen P.
    Bailey, Steven R.
    Calhoon, John H.
    Carabello, Blase A.
    Desai, Milind Y.
    Edwards, Fred H.
    Francis, Gary S.
    Gardner, Timothy J.
    Kappetein, A. Pieter
    Linderbaum, Jane A.
    Mukherjee, Chirojit
    Mukherjee, Debabrata
    Otto, Catherine M.
    Ruiz, Carlos E.
    Sacco, Ralph L.
    Smith, Donnette
    Thomas, James D.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : 1200 - 1254
  • [10] A prospective survey of patients with valvular heart disease in Europe:: The Euro Heart Survey on Valvular Heart Disease
    Iung, B
    Baron, G
    Butchart, EG
    Delahaye, F
    Gohlke-Bärwolf, C
    Levang, OW
    Tornos, P
    Vanoverschelde, JL
    Vermeer, F
    Boersma, E
    Ravaud, P
    Vahanian, A
    [J]. EUROPEAN HEART JOURNAL, 2003, 24 (13) : 1231 - 1243