A review on creatinine measurement techniques

被引:74
作者
Mohabbati-Kalejahi, Elham [1 ]
Azimirad, Vahid [1 ]
Bahrami, Manouchehr [1 ]
Ganbari, Ahmad [1 ]
机构
[1] Univ Tabriz, Sch Engn Emerging Technol, Ctr Excellence Mechantron, Tabriz, Iran
关键词
Creatinine; Biosensor; Kidney disease; MOLECULARLY IMPRINTED POLYMER; GLOMERULAR-FILTRATION-RATE; SERUM CREATININE; ELECTROCHEMICAL SENSOR; LIQUID-CHROMATOGRAPHY; SENSITIVE BIOSENSOR; URINARY CREATININE; POTENTIOMETRIC BIOSENSORS; SWITCH APPROACH; WHOLE-BLOOD;
D O I
10.1016/j.talanta.2012.04.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L-1 belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 109 条
[1]   Polymers in sensor applications [J].
Adhikari, B ;
Majumdar, S .
PROGRESS IN POLYMER SCIENCE, 2004, 29 (07) :699-766
[2]  
[Anonymous], 2002, ANAL BIOANAL CHEM, DOI [DOI 10.1007/s00216-002-1596-0, DOI 10.1007/S00216-002-1596-0]
[3]   Reference limits of plasma and serum creatinine concentrations from intra-laboratory data bases of several German and Italian medical centres Comparison between direct and indirect procedures [J].
Arzideh, Farhad ;
Wosniok, Werner ;
Haeckel, Rainer .
CLINICA CHIMICA ACTA, 2010, 411 (3-4) :215-221
[4]  
Benkert A, 2000, ELECTROANAL, V12, P1318, DOI 10.1002/1521-4109(200011)12:16<1318::AID-ELAN1318>3.0.CO
[5]  
2-M
[6]   A stable three-enzyme creatinine biosensor. 3. Immobilization of creatinine amidohydrolase and sensor development [J].
Berberich, JA ;
Chan, A ;
Boden, M ;
Russell, AJ .
ACTA BIOMATERIALIA, 2005, 1 (02) :193-199
[7]   A stable three enzyme creatinine biosensor. 2. Analysis of the impact of silver ions on creatine amidinohydrolase [J].
Berberich, JA ;
Yang, LW ;
Bahar, I ;
Russell, AJ .
ACTA BIOMATERIALIA, 2005, 1 (02) :183-191
[8]  
BONSNES RW, 1945, J BIOL CHEM, V158, P581
[9]   Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase [J].
Chen, J ;
Yan, F ;
Dai, Z ;
Ju, HX .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :330-336
[10]   An enzymeless electrochemical sensor for the selective determination of creatinine in human urine [J].
Chen, JC ;
Kumar, AS ;
Chung, HH ;
Chien, SH ;
Kuo, MC ;
Zen, JM .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) :473-480