Electrocatalytic activity of activated niclosamide on multi-walled carbon nanotubes glassy carbon electrode toward NADH oxidation

被引:6
作者
Lopes, Cleylton Bezerra [1 ,2 ,5 ]
dos Santos Silva, Francisco de Assis [3 ,5 ]
Lima, Phabyanno Rodrigues [2 ,5 ]
de Freitas, Johnnatan Duarte [2 ]
Sousa, Jonas dos Santos [2 ]
Kubota, Lauro Tatsuo [4 ,5 ]
Fonseca Goulart, Marilia Oliveira [1 ,5 ]
机构
[1] Univ Fed Alagoas UFAL, IQB, BR-57072970 Maceio, AL, Brazil
[2] IFAL, Inst Fed Educ Ciencia & Tecnol Alagoas, BR-57020600 Maceio, AL, Brazil
[3] IFG, Inst Fed Educ Ciencia & Tecnol Goias, BR-76400000 Uruacu, Go, Brazil
[4] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[5] Univ Estadual Campinas, Inst Nacl Ciencia & Tecnol Bioanalit, BR-13084971 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Sensors; Chemically modified electrode; Niclosamide; Mediators; MWCNT; NADH; NICOTINAMIDE ADENINE-DINUCLEOTIDE; VOLTAMMETRIC DETERMINATION; PASTE ELECTRODE; COMPOSITE; ACID; NANOPARTICLES; DERIVATIVES; MEDIATOR; DAMAGE;
D O I
10.1007/s10008-015-2862-3
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple and sensitive method for the electrocatalytic detection of dihydronicotinamide adenine dinucleotide (NADH) on an activated niclosamide (activatedNIC)-based modified electrode, prepared on a glassy carbon electrode modified with multi-walled carbon nanotubes (GCE/MWCNT/activatedNIC), was developed. This modified electrode shows efficient electrocatalytic oxidation activity toward NADH, at an applied potential of 0.065 V vs Ag/AgCl, with a kinetic constant, k (kin), of 1.15 x 10(4) L mol(-1) s(-1), evaluated by chronoamperometry. The sensor presents a linear response range from 10.0 up to 280.0 mu M with limits of detection and quantification and sensitivity of 3 mu M, 10 mu M, and 2.4 nA mu M-1, respectively.
引用
收藏
页码:2819 / 2829
页数:11
相关论文
共 54 条
[1]   Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensor [J].
Abreu, FC ;
Goulart, MOF ;
Brett, AMO .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :913-919
[2]   Electrocatalytic oxidation of chlorophenols by electropolymerised nickel(II) tetrakis benzylmercapto and dodecylmercapto metallophthalocyanines complexes on gold electrodes [J].
Agboola, Bolade ;
Nyokong, Tebello .
ELECTROCHIMICA ACTA, 2007, 52 (15) :5039-5045
[3]   Poly-(3-methylthiophene)/carbon nanotubes hybrid composite-modified electrodes [J].
Aguei, L. ;
Pena-Farfal, C. ;
Yanez-Sedeno, P. ;
Pingarron, J. M. .
ELECTROCHIMICA ACTA, 2007, 52 (28) :7946-7952
[4]   Simultaneous determination of levodopa, NADH, and tryptophan using carbon paste electrode modified with carbon nanotubes and ferrocenedicarboxylic acid [J].
Akhgar, Mohammad Reza ;
Salari, Mohammad ;
Zamani, Hassan .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (04) :845-853
[5]  
Al-Hadiya Badraddin M H, 2005, Profiles Drug Subst Excip Relat Methodol, V32, P67, DOI 10.1016/S0099-5428(05)32002-8
[6]   Voltammetric determination of niclosamide at a glassy carbon electrode [J].
Alemu, H ;
Wagana, P ;
Tseki, PF .
ANALYST, 2002, 127 (01) :129-134
[7]   THE BIOLOGY AND TOXICOLOGY OF MOLLUSCICIDES, BAYLUSCIDE [J].
ANDREWS, P ;
THYSSEN, J ;
LORKE, D .
PHARMACOLOGY & THERAPEUTICS, 1982, 19 (02) :245-295
[8]  
[Anonymous], 1987, ANALYST, V112, P199
[9]  
Bard AJ, 2001, ELECTROCHEMICAL METH
[10]   Amperometric determination of NADH with Co3O4 nanosheet modified electrode [J].
Chen, Chi-Hao ;
Chen, Ying-Cih ;
Lin, Meng-Shan .
BIOSENSORS & BIOELECTRONICS, 2013, 42 :379-384