Comparison of optic nerve head parameters using Heidelberg Retina Tomograph 3 and spectral-domain optical coherence tomography

被引:16
|
作者
Sato, Shino [1 ]
Hirooka, Kazuyuki [1 ]
Baba, Tetsuya [1 ]
Shiraga, Fumio [1 ]
机构
[1] Kagawa Univ, Fac Med, Dept Ophthalmol, Miki, Kagawa 7610793, Japan
关键词
Heidelberg Retina Tomograph; optic nerve head; optical coherence tomography; FIBER LAYER THICKNESS; SCANNING LASER OPHTHALMOSCOPY; STRATUS OCT; GLAUCOMATOUS EYES; AGREEMENT; REPRODUCIBILITY; TOPOGRAPHY;
D O I
10.1111/j.1442-9071.2012.02782.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To assess the agreement between the Heidelberg Retina Tomograph and Cirrus spectral-domain optical coherence tomography (Cirrus HD-OCT [Carl Zeiss Meditec, Dublin, CA, USA]) when measuring optic disc parameters. Design: Prospective, cross-sectional study. Participants: A total of 96 glaucoma patients and 21 normal subjects were analysed. Methods: Optic nerve head measurements, including disc area, rim area, cup-to-disc ratio and cup volume were obtained using both the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany). Main Outcome Measurements: BlandAltman plots were used to evaluate the agreement between each of the optic disc parameters. Results: Although Cirrus HD-OCT values were smaller than Heidelberg Retina Tomograph 3 values for the disc and rim areas, overall the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 measurements were highly correlated (r = 0.657 to 0.821). As compared with Heidelberg Retina Tomograph 3, disc and rim areas tended to be minimized by Cirrus HD-OCT, especially when there were large disc and rim areas, although there was no relationship between the discrepancy and the level of measurement of the cup-to-disc ratio. The optical coherence tomography overestimated the Heidelberg Retina Tomograph-determined cup volume, especially when there were large cup volumes. Conclusions: BlandAltman analyses revealed that with the exception of the cup-to-disc ratio, there was poor agreement between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 morphometric measurements. In addition, with the exception of the cup-to-disc ratio, the optic nerve head measurements could not be directly compared between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [41] Spectral-Domain Optical Coherence Tomography Enhanced Depth Imaging of the Normal and Glaucomatous Nonhuman Primate Optic Nerve Head
    Yang, Hongli
    Qi, Jingjing
    Hardin, Christy
    Gardiner, Stuart K.
    Strouthidis, Nicholas G.
    Fortune, Brad
    Burgoyne, Claude F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 394 - 405
  • [42] Longitudinal Change Detected by Spectral Domain Optical Coherence Tomography in the Optic Nerve Head and Peripapillary Retina in Experimental Glaucoma
    Strouthidis, Nicholas G.
    Fortune, Brad
    Yang, Hongli
    Sigal, Ian A.
    Burgoyne, Claude F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1206 - 1219
  • [43] Retinal nerve fiber and optic disc morphology using spectral-domain optical coherence tomography in scleroderma patients
    Sahin-Atik, Sevinc
    Koc, Feray
    Akin-Sari, Sirin
    Ozmen, Mustafa
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (03) : 281 - 284
  • [44] Evaluation of Optic Nerve Development in Preterm and Term Infants Using Handheld Spectral-Domain Optical Coherence Tomography
    Tong, Amy Y.
    El-Dairi, Mays
    Maldonado, Ramiro S.
    Rothman, Adam L.
    Yuan, Eric L.
    Stinnett, Sandra S.
    Kupper, Laura
    Cotten, C. Michael
    Gustafson, Kathryn E.
    Goldstein, Ricki F.
    Freedman, Sharon F.
    Toth, Cynthia A.
    OPHTHALMOLOGY, 2014, 121 (09) : 1818 - 1826
  • [45] Structure-Function Relationships With Spectral-Domain Optical Coherence Tomography Retinal Nerve Fiber Layer and Optic Nerve Head Measurements
    Pollet-Villard, Frederic
    Chiquet, Christophe
    Romanet, Jean-Paul
    Noel, Christian
    Aptel, Florent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (05) : 2953 - 2962
  • [46] Comparison of Diagnostic Ability Between Wide- Field Swept-Source Optical Coherence Tomography Imaging Maps and Heidelberg Retina Tomograph 3 Optic Nerve Head Assessment to Discriminate Glaucomatous and Non-glaucomatous Eyes
    Kourkoutas, Dimitrios
    Triantafyllopoulos, George
    Georgiou, Iordanis
    Karamaounas, Aristotelis
    Karamaounas, Nikolaos
    Sotiropulos, Konstadinos
    Kapralos, Dimitrios
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [47] Do biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?
    E. Elksne
    J. V. Stingl
    A. K. Schuster
    F. M. Wagner
    E. M. Hoffmann
    BMC Ophthalmology, 22
  • [48] Longitudinal Analysis of Progression in Glaucoma Using Spectral-Domain Optical Coherence Tomography
    Wessel, Julia M.
    Horn, Folkert K.
    Tornow, Ralf P.
    Schmid, Matthias
    Mardin, Christian Y.
    Kruse, Friedrich E.
    Juenemann, Anselm G.
    Laemmer, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3613 - 3620
  • [49] Development of a novel reference plane for the Heidelberg Retina Tomograph with optical coherence tomography measurements
    Park, KH
    Caprioli, J
    JOURNAL OF GLAUCOMA, 2002, 11 (05) : 385 - 391
  • [50] Imaging of Optic Nerve Head Drusen Improvements With Spectral Domain Optical Coherence Tomography
    Yi, Kayoung
    Mujat, Mircea
    Sun, Wei
    Burnes, Daina
    Latina, Mark A.
    Lin, Derrick T.
    Deschler, Daniel G.
    Rubin, Peter A. D.
    Park, Boris Hyle
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2009, 18 (05) : 373 - 378