Comparison of optic nerve head parameters using Heidelberg Retina Tomograph 3 and spectral-domain optical coherence tomography

被引:16
|
作者
Sato, Shino [1 ]
Hirooka, Kazuyuki [1 ]
Baba, Tetsuya [1 ]
Shiraga, Fumio [1 ]
机构
[1] Kagawa Univ, Fac Med, Dept Ophthalmol, Miki, Kagawa 7610793, Japan
关键词
Heidelberg Retina Tomograph; optic nerve head; optical coherence tomography; FIBER LAYER THICKNESS; SCANNING LASER OPHTHALMOSCOPY; STRATUS OCT; GLAUCOMATOUS EYES; AGREEMENT; REPRODUCIBILITY; TOPOGRAPHY;
D O I
10.1111/j.1442-9071.2012.02782.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To assess the agreement between the Heidelberg Retina Tomograph and Cirrus spectral-domain optical coherence tomography (Cirrus HD-OCT [Carl Zeiss Meditec, Dublin, CA, USA]) when measuring optic disc parameters. Design: Prospective, cross-sectional study. Participants: A total of 96 glaucoma patients and 21 normal subjects were analysed. Methods: Optic nerve head measurements, including disc area, rim area, cup-to-disc ratio and cup volume were obtained using both the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany). Main Outcome Measurements: BlandAltman plots were used to evaluate the agreement between each of the optic disc parameters. Results: Although Cirrus HD-OCT values were smaller than Heidelberg Retina Tomograph 3 values for the disc and rim areas, overall the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 measurements were highly correlated (r = 0.657 to 0.821). As compared with Heidelberg Retina Tomograph 3, disc and rim areas tended to be minimized by Cirrus HD-OCT, especially when there were large disc and rim areas, although there was no relationship between the discrepancy and the level of measurement of the cup-to-disc ratio. The optical coherence tomography overestimated the Heidelberg Retina Tomograph-determined cup volume, especially when there were large cup volumes. Conclusions: BlandAltman analyses revealed that with the exception of the cup-to-disc ratio, there was poor agreement between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 morphometric measurements. In addition, with the exception of the cup-to-disc ratio, the optic nerve head measurements could not be directly compared between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [31] Better performance of RTVue than Cirrus spectral-domain optical coherence tomography in detecting band atrophy of the optic nerve
    Nakamura, Makoto
    Ishikawa-Tabuchi, Kumiko
    Kanamori, Akiyasu
    Yamada, Yuko
    Negi, Akira
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (10) : 1499 - 1507
  • [32] Repeatability of Optic Nerve Head Parameters Measured by Spectral-Domain OCT in Healthy Eyes
    Savini, Giacomo
    Carbonelli, Michele
    Parisi, Vincenzo
    Barboni, Piero
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (03) : 209 - 215
  • [33] Spectral-domain optical coherence tomography reveals prelaminar membranes in optic nerve head pallor in eyes with retinitis pigmentosa
    Al Rashaed, Saba
    Khan, Arif O.
    Nowilaty, Sawsan R.
    Edward, Deepak P.
    Kozak, Igor
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (01) : 77 - 81
  • [34] The effect of cataract surgery on imaging optic nerve head topography with the Heidelberg Retina Tomograph
    Falck, Aura A. K.
    Saarela, Ville
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (01) : 80 - 85
  • [35] The effect of contour line position on optic nerve head analysis by Heidelberg Retina Tomograph
    Iester, Michele
    Mariotti, Valeria
    Lanza, Francesco
    Calabria, Giovanni
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (06) : 942 - 948
  • [36] Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography
    Pinilla Lozano, Isabel
    Lopez de la Fuente, Carmen
    Segura, Francisco
    Orduna Hospital, Elvira
    Sanchez-Cano, Ana
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (02) : 209 - 215
  • [37] Measurement of the hypotenuse of the vertical optic nerve head cup with spectral-domain optical coherence tomography for the structural diagnosis of glaucoma
    Lavinsky, Fabio
    Benfica, Camila Zanella
    Castoldi, Nedio
    Cruz do Carmo Chaves, Anne Elise
    de Arruda Mello, Paulo Augusto
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 215 - 225
  • [38] Comparison of Spectral Domain Optical Coherence Tomography and Heidelberg Retinal Tomograph III Retina Module in the Measurement of Clinically Significant Diabetic Macular Edema
    Guzey, Mustafa
    Adibelli, Fatih Mehmet
    Ozcan, Huseyin
    OPHTHALMOLOGICA, 2014, 232 : 53 - 53
  • [39] Spectral-Domain Optical Coherence Tomography Findings in Cavernous Hemangioma of the Optic Disk
    Robinet, Antoine
    Korobelnik, Jean-Francois
    Quentel, Gabriel
    Rougier, Marie-Benedicte
    Gontier, Brigitte
    Delyfer, Marie-Noelle
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (02): : E11 - E13
  • [40] Variation in Optic Nerve and Macular Structure with Age and Race with Spectral-Domain Optical Coherence Tomography
    Girkin, Christopher A.
    McGwin, Gerald, Jr.
    Sinai, Micheal J.
    Sekhar, G. Chandra
    Fingeret, Murrey
    Wollstein, Gadi
    Varma, Rohit
    Greenfield, David
    Liebmann, Jeffery
    Araie, Makoto
    Tomita, Goji
    Maeda, Naoyuki
    Garway-Heath, David F.
    OPHTHALMOLOGY, 2011, 118 (12) : 2403 - 2408