Comparison of optic nerve head parameters using Heidelberg Retina Tomograph 3 and spectral-domain optical coherence tomography

被引:16
|
作者
Sato, Shino [1 ]
Hirooka, Kazuyuki [1 ]
Baba, Tetsuya [1 ]
Shiraga, Fumio [1 ]
机构
[1] Kagawa Univ, Fac Med, Dept Ophthalmol, Miki, Kagawa 7610793, Japan
关键词
Heidelberg Retina Tomograph; optic nerve head; optical coherence tomography; FIBER LAYER THICKNESS; SCANNING LASER OPHTHALMOSCOPY; STRATUS OCT; GLAUCOMATOUS EYES; AGREEMENT; REPRODUCIBILITY; TOPOGRAPHY;
D O I
10.1111/j.1442-9071.2012.02782.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To assess the agreement between the Heidelberg Retina Tomograph and Cirrus spectral-domain optical coherence tomography (Cirrus HD-OCT [Carl Zeiss Meditec, Dublin, CA, USA]) when measuring optic disc parameters. Design: Prospective, cross-sectional study. Participants: A total of 96 glaucoma patients and 21 normal subjects were analysed. Methods: Optic nerve head measurements, including disc area, rim area, cup-to-disc ratio and cup volume were obtained using both the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany). Main Outcome Measurements: BlandAltman plots were used to evaluate the agreement between each of the optic disc parameters. Results: Although Cirrus HD-OCT values were smaller than Heidelberg Retina Tomograph 3 values for the disc and rim areas, overall the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 measurements were highly correlated (r = 0.657 to 0.821). As compared with Heidelberg Retina Tomograph 3, disc and rim areas tended to be minimized by Cirrus HD-OCT, especially when there were large disc and rim areas, although there was no relationship between the discrepancy and the level of measurement of the cup-to-disc ratio. The optical coherence tomography overestimated the Heidelberg Retina Tomograph-determined cup volume, especially when there were large cup volumes. Conclusions: BlandAltman analyses revealed that with the exception of the cup-to-disc ratio, there was poor agreement between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 morphometric measurements. In addition, with the exception of the cup-to-disc ratio, the optic nerve head measurements could not be directly compared between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [21] Descriptive information of topographic parameters computed at the optic nerve head with the Heidelberg Retina Tomograph
    Saruhan, A
    Orgül, S
    Koçak, I
    Prünte, C
    Flammer, J
    JOURNAL OF GLAUCOMA, 1998, 7 (06) : 420 - 429
  • [22] Comparison of optic nerve head topography in healthy adults using a Heidelberg retina tomograph and retinal thickness analyzer
    Rekič A.
    Breznik M.
    Cvenkel B.
    International Ophthalmology, 2007, 27 (1) : 1 - 9
  • [24] Comparison of Automated Analysis of Cirrus HD OCT Spectral-Domain Optical Coherence Tomography with Stereo Photographs of the Optic Disc
    Sharma, Ashish
    Oakley, Jonathan D.
    Schiffman, Joyce C.
    Budenz, Donald L.
    Anderson, Douglas R.
    OPHTHALMOLOGY, 2011, 118 (07) : 1348 - 1357
  • [25] Do biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?
    Elksne, E.
    Stingl, J., V
    Schuster, A. K.
    Wagner, F. M.
    Hoffmann, E. M.
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [26] Evaluation of the optic nerve head with the Heidelberg retina tomograph in diabetes mellitus
    Tekeli, Oya
    Turacli, M. Erol
    Atmaca, Leyla Suna
    Elhan, Atilla Halil
    OPHTHALMOLOGICA, 2008, 222 (03) : 168 - 172
  • [27] Spectral domain optical coherence tomography evaluation of the feline optic nerve and peripapillary retina
    Gomes, Filipe Espinheira
    Parry, Stephen
    Ledbetter, Eric
    VETERINARY OPHTHALMOLOGY, 2019, 22 (05) : 623 - 632
  • [28] Optic Nerve Parameters in Obese Children as Measured by Spectral Domain Optical Coherence Tomography
    Koca, Semra
    Keskin, Meliksah
    Saricaoglu, M. Sinan
    Koca, Serkan Bilge
    Duru, Necati
    Hamurcu, Mualla Sahin
    Muratoglu, Nursel Sahin
    Aycan, Zehra
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (06) : 743 - 747
  • [29] Evaluation of optic nerve head configuration in various types of optic neuropathy with Heidelberg Retina Tomograph
    Nagai-Kusuhara, A.
    Nakamura, M.
    Kanamori, A.
    Nakanishi, Y.
    Kusuhara, S.
    Negi, Akira
    EYE, 2008, 22 (09) : 1154 - 1160
  • [30] Evaluation of optic nerve head configuration in various types of optic neuropathy with Heidelberg Retina Tomograph
    A Nagai-Kusuhara
    M Nakamura
    A Kanamori
    Y Nakanishi
    S Kusuhara
    Akira Negi
    Eye, 2008, 22 : 1154 - 1160