Comparison of optic nerve head parameters using Heidelberg Retina Tomograph 3 and spectral-domain optical coherence tomography

被引:16
|
作者
Sato, Shino [1 ]
Hirooka, Kazuyuki [1 ]
Baba, Tetsuya [1 ]
Shiraga, Fumio [1 ]
机构
[1] Kagawa Univ, Fac Med, Dept Ophthalmol, Miki, Kagawa 7610793, Japan
关键词
Heidelberg Retina Tomograph; optic nerve head; optical coherence tomography; FIBER LAYER THICKNESS; SCANNING LASER OPHTHALMOSCOPY; STRATUS OCT; GLAUCOMATOUS EYES; AGREEMENT; REPRODUCIBILITY; TOPOGRAPHY;
D O I
10.1111/j.1442-9071.2012.02782.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To assess the agreement between the Heidelberg Retina Tomograph and Cirrus spectral-domain optical coherence tomography (Cirrus HD-OCT [Carl Zeiss Meditec, Dublin, CA, USA]) when measuring optic disc parameters. Design: Prospective, cross-sectional study. Participants: A total of 96 glaucoma patients and 21 normal subjects were analysed. Methods: Optic nerve head measurements, including disc area, rim area, cup-to-disc ratio and cup volume were obtained using both the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany). Main Outcome Measurements: BlandAltman plots were used to evaluate the agreement between each of the optic disc parameters. Results: Although Cirrus HD-OCT values were smaller than Heidelberg Retina Tomograph 3 values for the disc and rim areas, overall the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 measurements were highly correlated (r = 0.657 to 0.821). As compared with Heidelberg Retina Tomograph 3, disc and rim areas tended to be minimized by Cirrus HD-OCT, especially when there were large disc and rim areas, although there was no relationship between the discrepancy and the level of measurement of the cup-to-disc ratio. The optical coherence tomography overestimated the Heidelberg Retina Tomograph-determined cup volume, especially when there were large cup volumes. Conclusions: BlandAltman analyses revealed that with the exception of the cup-to-disc ratio, there was poor agreement between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 morphometric measurements. In addition, with the exception of the cup-to-disc ratio, the optic nerve head measurements could not be directly compared between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [1] Comparison of Spectral-Domain Optical Coherence Tomography and Heidelberg Retina Tomograph III Optic Nerve Head Parameters in Glaucoma
    Seymenoglu, Goktug
    Baser, Esin
    Ozturk, Bilge
    OPHTHALMOLOGICA, 2013, 229 (02) : 101 - 105
  • [2] Optic nerve head assessment: comparison of Cirrus optic coherence tomography and Heidelberg Retinal Tomograph 3
    Kratz, Assaf
    Lim, Ridia
    Goldberg, Ivan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (08) : 734 - 744
  • [3] Comparison of Optic Nerve Head Parameter Measurements Obtained by Time-domain and Spectral-domain Optical Coherence Tomography
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Sbreglia, Alessandra
    Deluigi, Giulia
    Parisi, Vincenzo
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 384 - 389
  • [4] Effect of head tilt on repeatability of optic nerve head parameters using Cirrus spectral-domain optical coherence tomography
    Koh, Lilian Hui Li
    Ismail, Muhammad Amir
    Yap, Sae Cheong
    Wong, Elizabeth Poh Ying
    Yip, Leonard Wei Leon
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (08) : 1170 - 1175
  • [5] Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Study on Diagnostic Agreement with Heidelberg Retinal Tomograph
    Leung, Christopher Kai-shun
    Ye, Cong
    Weinreb, Robert N.
    Cheung, Carol Yim Lui
    Qiu, Quanliang
    Liu, Shu
    Xu, Guihua
    Lam, Dennis Shun Chiu
    OPHTHALMOLOGY, 2010, 117 (02) : 267 - 274
  • [6] Optic nerve head parameters of high-definition optical coherence tomography and Heidelberg retina tomogram in perimetric and preperimetric glaucoma
    Begum, Viquar Unnisa
    Addepalli, Uday Kumar
    Senthil, Sirisha
    Garudadri, Chandra Sekhar
    Rao, Harsha Laxmana
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (04) : 277 - 284
  • [7] Effect of head tilt on repeatability of optic nerve head parameters using Cirrus spectral-domain optical coherence tomography
    Lilian Hui Li Koh
    Muhammad Amir Ismail
    Sae Cheong Yap
    Elizabeth Poh Ying Wong
    Leonard Wei Leon Yip
    International Journal of Ophthalmology, 2016, (08) : 1170 - 1175
  • [8] Optic Disc Imaging with Spectral-Domain Optical Coherence Tomography Variability and Agreement Study with Heidelberg Retinal Tomograph
    Yang, Bingzhi
    Ye, Cong
    Yu, Marco
    Liu, Shu
    Lam, Dennis Shun Chiu
    Leung, Christopher Kai-shun
    OPHTHALMOLOGY, 2012, 119 (09) : 1852 - 1857
  • [9] Sensitivity and specificity of time-domain and spectral-domain optical coherence tomography in differentiating optic nerve head drusen and optic disc oedema
    Flores-Rodriguez, Patricia
    Gili, Pablo
    Dolores Martin-Rios, Maria
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (03) : 213 - 221