Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
|
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 50 条
  • [31] Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience
    Delgado Sanchez-Gracian, Carlos
    Oca Pernas, Roque
    Trinidad Lopez, Carmen
    Santos Armentia, Eloisa
    Vaamonde Liste, Antonio
    Vazquez Caamano, Maria
    Tardaguila de la Fuente, Gonzalo
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3199 - 3207
  • [32] Assessment of lobar perfusion in smokers according to the presence and severity of emphysema: preliminary experience with dual-energy CT angiography
    Pansini, Vittorio
    Remy-Jardin, Martine
    Faivre, Jean-Baptiste
    Schmidt, Bernhard
    Dejardin-Bothelo, Alexis
    Perez, Thierry
    Delannoy, Valerie
    Duhamel, Alain
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2834 - 2843
  • [33] Dual-energy perfusion CT of non-diseased lung segments using dual-source CT: correlation with perfusion SPECT
    Kunihiro, Yoshie
    Okada, Munemasa
    Matsunaga, Naofumi
    Sano, Yuichi
    Kudomi, Shohei
    Suga, Kazuyoshi
    Kido, Shoji
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (02) : 99 - 104
  • [34] Dual-energy perfusion CT of non-diseased lung segments using dual-source CT: correlation with perfusion SPECT
    Yoshie Kunihiro
    Munemasa Okada
    Naofumi Matsunaga
    Yuichi Sano
    Shohei Kudomi
    Kazuyoshi Suga
    Shoji Kido
    Japanese Journal of Radiology, 2013, 31 : 99 - 104
  • [35] Assessment of lobar perfusion in smokers according to the presence and severity of emphysema: preliminary experience with dual-energy CT angiography
    Vittorio Pansini
    Martine Remy-Jardin
    Jean-Baptiste Faivre
    Bernhard Schmidt
    Alexis Dejardin-Bothelo
    Thierry Perez
    Valérie Delannoy
    Alain Duhamel
    Jacques Remy
    European Radiology, 2009, 19 : 2834 - 2843
  • [36] VOXSI: A voxelized single- and dual-energy CT scenario generator for quantitative imaging
    van der Heyden, Brent
    Schyns, Lotte E. J. R.
    Podesta, Mark
    Vaniqui, Ana
    Almeida, Isabel P.
    Landry, Guillaume
    Verhaegen, Frank
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 47 - 52
  • [37] Quantitative Dual-Energy CT Imaging for Proton Stopping Power Computation
    Han, D.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 496 - 496
  • [38] Imaging of acute pulmonary embolism using a dual energy CT system with rapid kVp switching: Initial results
    Geyer, Lucas L.
    Scherr, Michael
    Koerner, Markus
    Wirth, Stefan
    Deak, Paul
    Reiser, Maximilian F.
    Linsenmaier, Ulrich
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3711 - 3718
  • [39] Spectral CT imaging of myocardial infarction: preliminary animal experience
    Pang, Li-fang
    Zhang, Huan
    Lu, Wei
    Yang, Wen-jie
    Xiao, Hua
    Xu, Wei-qing
    Chen, Ying
    Liu, Yan
    Bu, Yu-lian
    Pan, Zi-lai
    Chen, Ke-min
    Yan, Fu-hua
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 133 - 138
  • [40] Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Masaki Katsura
    Shigeru Kiryu
    Naoki Yoshioka
    Akira Kunimatsu
    Kenji Ino
    Kuni Ohtomo
    Japanese Journal of Radiology, 2012, 30 : 34 - 39