Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
|
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 50 条
  • [21] Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Katsura, Masaki
    Kiryu, Shigeru
    Yoshioka, Naoki
    Kunimatsu, Akira
    Ino, Kenji
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (01) : 34 - 39
  • [22] Dual-Energy CT Perfusion During Pharmacologic Stress for the Assessment of Myocardial Perfusion Defects Using a Second-Generation Dual-Source CT: A Comparison With Cardiac Magnetic Resonance Imaging
    Kim, Sung Mok
    Chang, Sung-A
    Shin, Wonseon
    Choe, Yeon Hyeon
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 44 - 52
  • [23] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Hyun Woo Goo
    Pediatric Radiology, 2010, 40 : 1536 - 1544
  • [24] Diagnostic value of Flash dual-source CT coronary artery imaging combined with dual-energy myocardial perfusion imaging for coronary heart disease
    Zhao, Rui-Ping
    Hao, Zhi-Ru
    Song, Zhi-Jun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 7 (04) : 865 - 868
  • [25] Quantitative dual-energy CT techniques in the abdomen
    Toia, Giuseppe V.
    Mileto, Achille
    Wang, Carolyn L.
    Sahani, Dushyant V.
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3003 - 3018
  • [26] Quantitative myocardial perfusion imaging in a porcine ischemia model using a prototype spectral detector CT system
    Fahmi, Rachid
    Eck, Brendan L.
    Levi, Jacob
    Fares, Anas
    Dhanantwari, Amar
    Vembar, Mani
    Bezerra, Hiram G.
    Wilson, David L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06) : 2407 - 2431
  • [27] Normalized Dual-Energy Iodine Ratio Best Differentiates Renal Cell Carcinoma Subtypes Among Quantitative Imaging Biomarkers From Perfusion CT and Dual-Energy CT
    Manoharan, Dinesh
    Netaji, Arjunlokesh
    Diwan, Kanika
    Sharma, Sanjay
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (06) : 1389 - 1397
  • [28] Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model
    Scherer, Kai
    Hammel, Johannes
    Sellerer, Thorsten
    Mechlem, Korbinian
    Renger, Bernhard
    Baehr, Andrea
    Kupatt, Christian
    Hinkel, Rabea
    Herzen, Julia
    Pfeiffer, Franz
    Rummeny, Ernst
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [29] Performance evaluation of dual-energy CT and differential phase contrast CT in quantitative imaging applications
    Zhang, Xin
    Su, Ting
    Yang, Jiecheng
    Zhu, Jiongtao
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    MEDICAL PHYSICS, 2022, 49 (02) : 1123 - 1138
  • [30] Dual-Energy Perfusion-CT in Recurrent Pancreatic Cancer - Preliminary Results
    Fritz, F.
    Skornitzke, S.
    Hackert, T.
    Kauczor, H. U.
    Stiller, W.
    Grenacher, L.
    Klauss, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (06): : 559 - 565