Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 23 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Adenosine-Stress Dynamic Myocardial CT Perfusion Imaging Initial Clinical Experience [J].
Bastarrika, Gorka ;
Ramos-Duran, Luis ;
Rosenblum, Michael A. ;
Kang, Doo Kyoung ;
Rowe, Garrett W. ;
Schoepf, U. Joseph .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :306-313
[3]   Adenosine-Induced Stress Myocardial Perfusion Imaging Using Dual-Source Cardiac Computed Tomography [J].
Blankstein, Ron ;
Shturman, Leon D. ;
Rogers, Ian S. ;
Rocha-Filho, Jose A. ;
Okada, David R. ;
Sarwar, Ammar ;
Soni, Anand V. ;
Bezerra, Hiram ;
Ghoshhajra, Brian B. ;
Petranovic, Milena ;
Loureiro, Ricardo ;
Feuchtner, Gudrun ;
Gewirtz, Henry ;
Hoffmann, Udo ;
Mamuya, Wilfred S. ;
Brady, Thomas J. ;
Cury, Ricardo C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (12) :1072-1084
[4]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[5]   Adenosine Stress 64- and 256-Row Detector Computed Tomography Angiography and Perfusion Imaging A Pilot Study Evaluating the Transmural Extent of Perfusion Abnormalities to Predict Atherosclerosis Causing Myocardial Ischemia [J].
George, Richard T. ;
Arbab-Zadeh, Armin ;
Miller, Julie M. ;
Kitagawa, Kakuya ;
Chang, Hyuk-Jae ;
Bluemke, David A. ;
Becker, Lewis ;
Yousuf, Omair ;
Texter, John ;
Lardo, Albert C. ;
Lima, Joao A. C. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (03) :174-182
[6]   Myocardial Viability by Dual-Energy Delayed Enhancement Computed Tomography [J].
Hamilton-Craig, Christian ;
Seltmann, Martin ;
Ropers, Dieter ;
Achenbach, Stephan .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (02) :207-208
[7]   Stress and Rest Dynamic Myocardial Perfusion Imaging by Evaluation of Complete Time-Attenuation Curves With Dual-Source CT [J].
Ho, Kheng-Thye ;
Chua, Kia-Chong ;
Klotz, Ernst ;
Panknin, Christoph .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (08) :811-820
[8]   Dual-Energy Computed Tomography for Integrative Imaging of Coronary Artery Disease: Principles and Clinical Applications [J].
Kang, Doo Kyoung ;
Schoepf, U. Joseph ;
Bastarrika, Gorka ;
Nance, John W., Jr. ;
Abro, Joseph A. ;
Ruzsics, Balazs .
SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (04) :276-291
[9]   Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography [J].
Ko, Sung Min ;
Choi, Jin Woo ;
Song, Meong Gun ;
Shin, Je Kyoun ;
Chee, Hyun Kun ;
Chung, Hyun Woo ;
Kim, Dong Hun .
EUROPEAN RADIOLOGY, 2011, 21 (01) :26-35
[10]   GENERALIZED IMAGE COMBINATIONS IN DUAL KVP DIGITAL RADIOGRAPHY [J].
LEHMANN, LA ;
ALVAREZ, RE ;
MACOVSKI, A ;
BRODY, WR ;
PELC, NJ ;
RIEDERER, SJ ;
HALL, AL .
MEDICAL PHYSICS, 1981, 8 (05) :659-667