Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
|
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 50 条
  • [1] Comparative diagnostic accuracy of dual-energy CT myocardial perfusion imaging by monochromatic energy versus material decomposition methods
    Danad, Ibrahim
    Cho, Iksung
    Elmore, Kimberly
    Schulman-Marcus, Joshua
    Hartaigh, Briain O.
    Stuijfzand, Wijnand J.
    Carrascosa, Patricia
    Min, James K.
    CLINICAL IMAGING, 2018, 50 : 1 - 4
  • [2] Prospectively ECG-Triggered Rapid kV-Switching Dual-Energy CT for Quantitative Imaging of Myocardial Perfusion
    So, Aaron
    Hsieh, Jiang
    Imai, Yasuhiro
    Narayanan, Suresh
    Kramer, John
    Procknow, Karen
    Dutta, Sandeep
    Leipsic, Jonathon
    Min, James K.
    LaBounty, Troy
    Lee, Ting-Yim
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (08) : 829 - 836
  • [3] Dual-energy CT and its potential use for quantitative myocardial CT perfusion
    So, Aaron
    Hsieh, Jiang
    Narayanan, Suresh
    Thibault, Jean-Baptiste
    Imai, Yasuhiro
    Dutta, Sandeep
    Leipsic, Jonathon
    Min, James
    LaBounty, Troy
    Lee, Ting-Yim
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 308 - 317
  • [4] Myocardial perfusion imaging with dual energy CT
    Jin, Kwang Nam
    De Cecco, Carlo N.
    Caruso, Damiano
    Tesche, Christian
    Spandorfer, Adam
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1914 - 1921
  • [5] Diagnostic Performance of Dual-Energy CT Stress Myocardial Perfusion Imaging: Direct Comparison With Cardiovascular MRI
    Ko, Sung Min
    Song, Meong Gun
    Chee, Hyun Kun
    Hwang, Hweung Kon
    Feuchtner, Gudrun Maria
    Min, James K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : W605 - W613
  • [6] Evaluation of myocardial viability in patients with myocardial ischemia reperfusion injury using the dual-energy CT myocardial blood pool imaging
    Ji, Qingyu
    Wang, Yuan
    Zhao, Ying
    Chen, Qingwei
    Gao, Yanfeng
    Zhou, Maorong
    Liu, Baoliang
    Han, Ruijuan
    Sun, Kai
    EUROPEAN RADIOLOGY, 2023, 33 (06) : 3819 - 3831
  • [7] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Bucher, Andreas M.
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Wolla, Christopher D.
    Canstein, Christian
    McQuiston, Andrew D.
    Krazinski, Aleksander W.
    De Cecco, Carlo N.
    Meinel, Felix G.
    Vogl, Thomas J.
    Geyer, Lucas L.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3215 - 3222
  • [8] Diagnostic accuracy of coronary CT angiography combined with dual-energy myocardial perfusion imaging for detection of myocardial infarction
    Han, Ruijuan
    Sun, Kai
    Lu, Bin
    Zhao, Ruiping
    Li, Kuncheng
    Yang, Xinchun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (01) : 207 - 213
  • [9] Dual-energy CT lung perfusion in systemic sclerosis: preliminary experience in 101 patients
    Dupont, Antoine
    Koether, Vincent
    Labreuche, Julien
    Felloni, Paul
    Perez, Thierry
    de Groote, Pascal
    Remy, Jacques
    Duhamel, Alain
    Hachulla, Eric
    Launay, David
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 401 - 413
  • [10] Performance evaluation of quantitative material decomposition in slow kVp switching dual-energy CT
    Ma, Chenchen
    Su, Ting
    Zhu, Jiongtao
    Zhang, Xin
    Zheng, Hairong
    Liang, Dong
    Wang, Na
    Zhang, Yunxin
    Ge, Yongshuai
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (01) : 69 - 85