Development of a sensitive method for simultaneous determination of fluticasone propionate and salmeterol in plasma samples by liquid chromatography-tandem mass spectrometry

被引:17
|
作者
Silvestro, Luigi [1 ]
Savu, Simona Rizea [1 ]
Savu, Simona Nicoleta [2 ]
Tudoroniu, Ariana [2 ]
Tarcomnicu, Isabela [2 ]
机构
[1] 3S Pharmacol Consultat & Res GmbH, D-27243 Harpstedt, Germany
[2] Pharma Serv Intl SRL, Bucharest 050853, Romania
关键词
fluticasone propionate; salmeterol; liquid chromatography; tandem mass-spectrometry; pharmacokinetics; BETA-AGONISTS; EQUINE URINE; INHALATION; LC/MS/MS; MS/MS;
D O I
10.1002/bmc.1708
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method for the fast simultaneous quantification of fluticasone propionate and salmeterol from plasma samples by liquid chromatographytandem mass spectrometry, with adequate sensitivity for pharmacokinetic applications, was developed and validated. The chromatographic separation and mass-spectrometric parameters were optimized for the retention and detection of the two compounds, despite quite different structures and properties. Two columns connected in series were used, cation-exchange (Zorbax 300-SCX, 5 cm x 2.1 mm, 5 mu m) and octadecyl (Discovery HSC18, 10 cm x 2.1 mm, 5 mu m). The mass-spectrometric interface was operated in negative electrospray ionization mode; high sensitivity and lesser matrix effects were obtained, permitting smaller consumption of plasma. The sample preparation was based on supported liquidliquid extraction in 96-well format plates that provided clean samples with a simplified procedure that was suitable for automation. The method was validated according to regulatory guidelines, by assessing lower limits of quantification, selectivity, linearity, accuracy, precision, extraction recoveries and matrix effects. A comparison with two other methods for the separate determination of fluticasone propionate and salmeterol in plasma samples, previously developed by our group, is presented. The statistical evaluation of the results obtained with the three methods on a set of unknown samples from treated patients demonstrated good correlation (R2 0.987 for fluticasone propionate and 0.967 for salmeterol). Copyright (c) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:627 / 635
页数:9
相关论文
共 50 条
  • [21] Development and Validation of a Liquid Chromatography-tandem Mass Spectrometry Method for the Simultaneous Determination of Acrivastine and Pseudoephedrine in Human Plasma and its Application in Pharmacokinetics
    He, J. -C.
    Feng, E. -F.
    Liu, M.
    Li, H. -L.
    Tian, M.
    Zhang, Q.
    Dong, L. -C.
    Xu, G. -L.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (10): : 449 - 456
  • [22] Reliable and sensitive determination of dutasteride in human plasma by liquid chromatography-tandem mass spectrometry
    Contractor, Pritesh
    Kurani, Hemal
    Guttikar, Swati
    Shrivastav, Pranav S.
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (09) : 1168 - 1176
  • [23] Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    Umezawa, Hironobu
    Lee, Xiao-Pen
    Arima, Yoshiko
    Hasegawa, Chika
    Izawa, Hikaru
    Kumazawa, Takeshi
    Sato, Keizo
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 702 - 711
  • [24] Development of a sensitive method for the determination of oxycodone and its major metabolites noroxycodone and oxymorphone in human plasma by liquid chromatography-tandem mass spectrometry
    Gaudette, Fleur
    Sirhan-Daneau, Andrea
    St-Onge, Maude
    Turgeon, Jacques
    Michaud, Veronique
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 : 174 - 180
  • [25] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of colchicine in human plasma
    Jiang, Yao
    Wang, Jiang
    Wang, Yingwu
    Li, Hao
    Fawcett, J. Paul
    Gu, Jingkai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 564 - 568
  • [26] Determination of procyanidins and their metabolites in plasma samples by improved liquid chromatography-tandem mass spectrometry
    Serra, Aida
    Macia, Alba
    Romero, Maria-Paz
    Salvado, Maria-Josepa
    Bustos, Mario
    Fernandez-Larrea, Juan
    Motilva, Maria-Jose
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (11-12): : 1169 - 1176
  • [27] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the determination of metoclopramide in human plasma: application to a bioequivalence study
    Inamadugu, Jaswanth Kumar
    Damaramadugu, Rajasekhar
    Mullangi, Ramesh
    Ponneri, Venkateswarlu
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 1006 - 1014
  • [28] Simultaneous determination of aceclofenac and its three metabolites in plasma using liquid chromatography-tandem mass spectrometry
    Kang, Wonku
    Kim, Eun-Young
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (03) : 587 - 591
  • [29] Simultaneous determination of clarithromycin, rifampicin and their main metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    de Velde, Femke
    Alffenaar, Jan-Willem C.
    Wessels, A. Mireille A.
    Greijdanus, Ben
    Uges, Donald R. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (18-19): : 1771 - 1777
  • [30] Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Manoj, S
    Koteshwara, M
    Wishu, S
    Varma, DP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) : 751 - 760