Comparison of few-view CT image reconstruction algorithms by constrained total-variation minimization based on different sampling bases

被引:0
|
作者
Wang, Haoyu [1 ]
Xie, Yaoqin [1 ]
Bao, Shanglian [1 ]
Li, Lei [2 ]
Yan, Bin [2 ]
机构
[1] Peking Univ, Beijing City Key Lab Med Phys & Engn, 201 Chengfu Rd, Beijing 100871, Peoples R China
[2] Informat Engn Univ, Inst Informat Engn, Dept Informat Res, Zhengzhou, Peoples R China
基金
美国国家科学基金会;
关键词
convex optimization; total-variation minimization; sparsity; incoherence; orthogonal basis; UNCERTAINTY PRINCIPLES; SIGNAL RECOVERY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this paper is to investigate how the choice of the sampling basis affects the reconstruction results of constrained total-variation (TV) minimization algorithms used for few-view computed tomography (CT). The reconstruction results between the algorithm based on frequency samples (AFS) and the algorithm based on projection samples (APS) are compared using numerical simulated data. Under same conditions, AFS exhibits better results compared with APS. These experimental results confirm that provided same conditions, the more incoherence between the basis for sampling Psi and the basis of the sparse signal Phi, the better reconstruction results of the constrained TV minimization algorithm can be achieved and better algorithms can be developed with the basis pairs (Phi, Psi).
引用
收藏
页码:443 / 446
页数:4
相关论文
共 50 条
  • [41] FBP Initialized Few-view CT Reconstruction Algorithm Using Similar Prior Image Constraint
    Zhang, Weikang
    Li, Jiansen
    Sun, Jianqi
    Zhao, Jun
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3949 - 3952
  • [42] The constrained split Bregman algorithm for enhancing the quality of image reconstruction and analysis in few-view computed tomography
    Bahrkazemi, Maryam
    Rohde, Alexander
    Fieres, Johannes
    Hess, Jonathan
    Guerrero, Patricio
    Gondrom-Linke, Sven
    Dewulf, Wim
    e-Journal of Nondestructive Testing, 2024, 29 (Special Issue):
  • [43] Few-View CT Image Reconstruction via Least-Squares Methods: Assessment and Optimization
    Perez, Monica Chillaron
    Vidal, Vicente E.
    Verdu, Gumersindo J.
    Quintana-Orti, Gregorio
    NUCLEAR SCIENCE AND ENGINEERING, 2024, 198 (02) : 193 - 206
  • [44] Non-local means improves total-variation constrained photoacoustic image reconstruction
    Yalavarthy, Phaneendra K.
    Kalva, Sandeep Kumar
    Pramanik, Manojit
    Prakash, Jaya
    JOURNAL OF BIOPHOTONICS, 2021, 14 (01)
  • [45] Enhanced frequency-domain optical image reconstruction in tissues through total-variation minimization
    Paulsen, KD
    Jiang, HB
    APPLIED OPTICS, 1996, 35 (19): : 3447 - 3458
  • [46] A perfect reconstruction property for PDE-constrained total-variation minimization with application in Quantitative Susceptibility Mapping*
    Bredies, Kristian
    Vicente, David
    ESAIM-CONTROL OPTIMISATION AND CALCULUS OF VARIATIONS, 2019, 25
  • [47] CT Reconstruction Based on Improved Total Variation Minimization
    Xu, Qiong
    Mou, Xuanqin
    Tang, Shaojie
    Zhang, Yanbo
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3241 - 3244
  • [48] DISPARITY-COMPENSATED TOTAL-VARIATION MINIMIZATION FOR COMPRESSED-SENSED MULTIVIEW IMAGE RECONSTRUCTION
    Liu, Ring
    Zhang, Chen
    Kim, Joohee
    2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 1458 - 1462
  • [49] Deep Efficient End-to-End Reconstruction (DEER) Network for Few-View Breast CT Image Reconstruction
    Xie, Huidong
    Shan, Hongming
    Cong, Wenxiang
    Liu, Chi
    Zhang, Xiaohua
    Liu, Shaohua
    Ning, Ruola
    Wang, Ge
    IEEE ACCESS, 2020, 8 : 196633 - 196646
  • [50] Noise properties of CT images reconstructed by use of constrained total-variation, data-discrepancy minimization
    Rose, Sean
    Andersen, Martin S.
    Sidky, Emil Y.
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2015, 42 (05) : 2690 - 2698