Nanomembrane Canister Architectures for the Visualization and Filtration of Oxyanion Toxins with One-Step Processing

被引:28
作者
Aboelmagd, Ahmed [1 ]
El-Safty, Sherif A. [1 ,2 ]
Shenashen, Mohamed A. [1 ]
Elshehy, Emad A. [1 ]
Khairy, Mohamed [1 ]
Sakaic, Masaru [3 ]
Yamaguchi, Hitoshi [1 ]
机构
[1] Natl Inst Mat Sci, Tsukuba, Ibaraki 3050047, Japan
[2] Waseda Univ, Grad Sch Adv Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[3] Univ Tsukuba, Ctr Res Isotopes & Environm Dynam, Tsukuba, Ibaraki 3050076, Japan
关键词
anions; membranes; nanotubes; sensors; toxicology; MESOPOROUS SILICA MONOLITHS; INORGANIC SELENIUM; ULTRASENSITIVE DETERMINATION; BIOLOGICAL MACROMOLECULES; ALUMINOSILICA MONOLITHS; CATALYTIC-ACTIVITY; NANOSENSOR DESIGN; VAPOR GENERATION; METAL-IONS; HOM-TYPE;
D O I
10.1002/asia.201500565
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nanomembrane canister-like architectures were fabricated by using hexagonal mesocylinder-shaped aluminosilica nanotubes (MNTs)-porous anodic alumina (PAA) hybrid nanochannels. The engineering pattern of the MNTs inside a 60m-long membrane channel enabled the creation of unique canister-like channel necks and cavities. The open-tubular canister architecture design provides controllable, reproducible, and one-step processing patterns of visual detection and rejection/permeation of oxyanion toxins such as selenite (SeO32-) in aquatic environments (i.e., in ground and river water sources) in the Ibaraki Prefecture of Japan. The decoration of organic ligand moieties such as omega chrome black blue (OCG) into inorganic Al2O3@tubular SiO2/Al2O3 canister membrane channel cavities led to the fabrication of an optical nanomembrane sensor (ONS). The OCG ligand was not leached from the canister as observed in washing, sensing, and recovery assays of selenite anions in solution, which enabled its multiple reuse. The ONS makes a variety of alternate processing analyses of selective quantification, visual detection, rejection/permeation, and recovery of toxic selenite quick and simple without using complex instrumentation. Under optimal conditions, the ONS canister exhibited a high selectivity toward selenite anions relative to other ions and a low-level detection limit of 0.0093m. Real analytical data showed that approximately 96% of SeO32- anions can be recovered from aquatic and wastewater samples. The ONS canister holds potential for field recovery applications of toxic selenite anions from water.
引用
收藏
页码:2467 / 2478
页数:12
相关论文
共 135 条
[1]   Fabrication of a highly selective nonenzymatic amperometric sensor for hydrogen peroxide based on nickel foam/cytochrome c modified electrode [J].
Akhtar, Naeem ;
El-Safty, Sherif A. ;
Khairy, Md. ;
El-Said, Waleed A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 :158-166
[2]  
[Anonymous], CURR CATAL
[3]   Selenium speciation analysis using inductively coupled plasma-mass spectrometry [J].
B'Hymer, C ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (01) :1-20
[4]  
Balaji T., 2006, ANGEW CHEM, V118, P7360, DOI DOI 10.1002/ange.200602453
[5]   Optical sensors based on nanostructured cage materials for the detection of toxic metal ions [J].
Balaji, Tatineni ;
El-Safty, Sherif A. ;
Matsunaga, Hideyuki ;
Hanaoka, Takaaki ;
Mizukami, Fujio .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (43) :7202-7208
[6]   Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD [J].
Bidari, Araz ;
Hemmatkhah, Payam ;
Jafarvand, Sanaz ;
Hosseini, Mohammad Reza Milani ;
Assadi, Yaghoub .
MICROCHIMICA ACTA, 2008, 163 (3-4) :243-249
[7]  
Biradar N. S., 1983, INORG CHIM ACTA, V18, P41
[8]   Cloud point extraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the speciation of inorganic selenium in environmental water samples [J].
Chen, Beibei ;
Hu, Bin ;
He, Man .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (19) :2894-2900
[9]   Precipitate coating on cellulose fibre as sorption medium for selenium preconcentration and speciation with hydride generation atomic fluorescence spectrometry [J].
Chen, Mingli ;
Yang, Ting ;
Wang, Jianhua .
ANALYTICA CHIMICA ACTA, 2009, 631 (01) :74-79
[10]  
Cheng K. L., 1992, HDB ORGANIC ANAL REA, P350