Observational Study of Humidified High-Flow Nasal Cannula Compared with Nasal Continuous Positive Airway Pressure

被引:157
|
作者
Lampland, Andrea L. [1 ]
Plumm, Brenda [1 ]
Meyers, Patricia A. [1 ]
Worwa, Cathy T. [1 ]
Mammel, Mark C. [1 ,2 ]
机构
[1] Childrens Hosp & Clin Minnesota, Infant Diagnost & Res Ctr, St Paul, MN USA
[2] Univ Minnesota, Sch Med, Dept Pediat, Div Neonatol, Minneapolis, MN 55455 USA
来源
JOURNAL OF PEDIATRICS | 2009年 / 154卷 / 02期
关键词
EXPIRATORY PRESSURE; PHARYNGEAL PRESSURE; ESOPHAGEAL PRESSURE; INFANTS; BIRTH; CPAP; INTUBATION; MANAGEMENT;
D O I
10.1016/j.jpeds.2008.07.021
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives To conduct an in Nitro evaluation of a humidified high-flow nasal cannula (HFNC) system at different flows, cannula sizes, and air leaks and also an in vivo analysis of mean end-expiratory esophageal pressure (EEEP) from nasal continuous positive airway pressure at 6 cm H2O (NCPA+6) versus HFNC. Study design In the in vitro study, we measured HFNC system pressure and flow, with varying degrees of leak and with and without the use of a pressure-limiting valve. In the in vivo study, we measured EEEP in 15 newborns on NCPAP+6 and then on HFNC at 6 L/minute, with flow decreased by 1 L/minute every 30 minutes. Heart rate, respiratory rate, fraction of inspired oxygen, arterial oxygen saturation, respiratory distress syndrome score, and EEEP were recorded for each intervention. Data analysis was done using repeated-measures analysis of variance and linear regression. Results In the in Nitro study. in the absence of leads, the pressures were limited by the pressure-limiting valve only at flows : 2 L/minute. With leaks of 30% and 50%, delivered pressures were always < 3 cm H2O. In the in vivo study, respiratory rate increased from baseline (NCPAP+6) as flow decreased (P < .02). Intrapatient and interpatient coefficients of variation were always high. Conclusions A pressure-limiting valve is necessary in a HFNC system. Although mean EEEP levels were similar in NCPAP+6 and HFNC, tachypnea developed as flow diminished. This system apparently cannot predict EEEP, because of interpatient and intrapatient variation. (J Pediatr 2009;154:177-82)
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [31] Heated Humidified High-Flow Nasal Cannula: Impact on Neonatal Outcomes
    Jeffery, Rachael C. Heath
    Todd, David A.
    RESPIRATORY CARE, 2016, 61 (10) : 1428 - 1429
  • [32] Heated, Humidified High-Flow Nasal Cannula Versus Nasal CPAP for Respiratory Support in Neonates
    Yoder, Bradley A.
    Stoddard, Ronald A.
    Li, Ma
    King, Jerald
    Dirnberger, Daniel R.
    Abbasi, Soraya
    PEDIATRICS, 2013, 131 (05) : E1482 - E1490
  • [33] Heated humidified high-flow nasal cannula versus nasal continuous positive airways pressure for respiratory support in preterm neonates - A noninferiority trial at a tertiary care center
    Charki, Siddu
    Patil, Priyanka Keval
    Hadalgi, Laxmi
    Kulkarni, Trimal
    Loni, Ramaning
    Karva, M. M.
    Bidari, Laxman H.
    JOURNAL OF CLINICAL NEONATOLOGY, 2020, 9 (03) : 168 - 174
  • [34] Effect of Nasal Continuous Positive Airway Pressure on Retinopathy of Prematurity in Preterm Newborns: A Comparative Analysis with Mechanical Ventilation and High-Flow Nasal Cannula Therapy
    Cioboata, Daniela M.
    Manea, Aniko M.
    Costescu, Oana C.
    Doandes, Florina M.
    Brandibur, Timea E.
    Lungu, Nicoleta
    Dinu, Mihai
    Stoica, Florina
    Iacob, Radu E.
    Boia, Marioara
    MEDICAL SCIENCE MONITOR, 2024, 30
  • [35] High-flow nasal cannulae in the management of apnea of prematurity: A comparison with conventional nasal continuous positive airway pressure
    Sreenan, C
    Lemke, RP
    Hudson-Mason, A
    Osiovich, H
    PEDIATRICS, 2001, 107 (05) : 1081 - 1083
  • [36] Is there a role for humidified heated high-flow nasal cannula therapy in paediatric emergency departments?
    Long, Elliot
    Babl, Franz E.
    Duke, Trevor
    EMERGENCY MEDICINE JOURNAL, 2016, 33 (06) : 386 - 389
  • [37] The Role of Heated Humidified High-flow Nasal Cannula as Noninvasive Respiratory Support in Neonates
    Chao, Ke-Yun
    Chen, Yi-Ling
    Tsai, Li-Yi
    Chien, Yu-Hsuan
    Mu, Shu-Chi
    PEDIATRICS AND NEONATOLOGY, 2017, 58 (04): : 295 - 302
  • [38] The Clinical Impact of Heated Humidified High-Flow Nasal Cannula on Pediatric Respiratory Distress
    Kawaguchi, Atsushi
    Yasui, Yutaka
    deCaen, Allan
    Garros, Daniel
    PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (02) : 112 - 119
  • [39] High-flow nasal cannula versus nasal continuous positive airway pressure for respiratory support in preterm infants: a meta-analysis of randomized controlled trials
    Hong, Hui
    Li, Xiao-xia
    Li, Jing
    Zhang, Zhi-qun
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2021, 34 (02): : 259 - 266
  • [40] Clinical review of High Flow Nasal Cannula and Continuous Positive Airway Pressure in pediatric acute respiratory distress
    Kadafi, Kurniawan Taufiq
    Yuliarto, Saptadi
    Monica, Charity
    Susanto, William Prayogo
    ANNALS OF MEDICINE AND SURGERY, 2022, 73