Ultra High Voltage Transmission in China: Developments, Current Status and Future Prospects

被引:219
作者
Huang, Daochun [1 ]
Shu, Yinbiao [2 ]
Ruan, Jiangjun [1 ]
Hu, Yi [3 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Hubei, Peoples R China
[2] SGCC, Beijing 100031, Peoples R China
[3] State Grid Elect Power Res Inst SGCC, Wuhan 430074, Peoples R China
关键词
Alternating current (AC); direct current (DC); electromagnetic environment; equipment manufacture; lightning performance; live-line working; operation and maintenance; over-voltage and insulation coordination; simulation center; test and demonstration transmission line; UHV AC test base; UHV DC test base; ultra high voltage (UHV); FLASHOVER PERFORMANCE; COMPOSITE INSULATORS; POWER;
D O I
10.1109/JPROC.2009.2013613
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The developments and current status of ultra high voltage (UHV) alternating current (AC) and direct current (DC) transmission in China were reviewed in this paper. The UHV transmission historical developments in the past twenty years; the demand of development UHV transmission; the research results of the UHV key technologies including electromagnetic environment, over-voltage and insulation coordination, lightning performance, live-line working and equipment manufacture recent years in China; the design parameters and construction of UHV AC, UHV DC test and demonstration transmission lines, UHV AC, DC test bases and state grid simulation center were introduced. The suggestions at the aspects of UHV transmission future design, construction, commercial operation and maintenance were simply presented and discussed. The review and discussion are important for the safe and reliable operation of UHV grid in China and can be a reference for other countries that want to develop UHV AC and DC transmission.
引用
收藏
页码:555 / 583
页数:29
相关论文
共 104 条
[1]  
ASTROM U, 2006, 2006 INT C POW SYST, P1
[2]  
BAICHENG W, 2007, ELECT EQUIPMENT, V8, P30
[3]  
BAOQUAN W, 2006, 2006 INT C POW SYST
[4]  
BAOYING W, 2006, POWER SYSTEM TECHNOL, V30, P5
[5]  
BISEWSKI B, 2005, INT WORKSH 800 KV HV, P1
[6]  
Bo ZQ, 2007, 2007 IEEE POWER ENGINEERING SOCIETY CONFERENCE AND EXPOSITION IN AFRICA, VOLS 1 AND 2, P7
[7]   Development and comparison of a full-scale car display and communication system by applying Augmented Reality [J].
Chen, Kuen-Meau ;
Chen, Lin-Lin ;
Shen, Siu-Tsen .
DISPLAYS, 2008, 29 (01) :33-40
[8]   Accounting for weak discontinuities and moving boundaries in the context of the Natural Element Method and model reduction techniques [J].
Chinesta, F. ;
Cueto, E. ;
Joyot, P. ;
Villon, P. .
IUTAM SYMPOSIUM ON DISCRETIZATION METHODS FOR EVOLVING DISCONTINUITIES, 2007, 5 :37-+
[9]   Spread of Staphylococcus aureus clinical isolates carrying Panton-Valentine leukocidin genes during a 3-year period in Greece [J].
Chini, V ;
Petinaki, E ;
Foka, A ;
Paratiras, S ;
Dimitracopoulos, G ;
Spiliopoulou, I .
CLINICAL MICROBIOLOGY AND INFECTION, 2006, 12 (01) :29-34
[10]  
CHUNYANG R, 2007, ELECT EQUIPMENT, V8, P35