Effects of Open-Irrigated Radiofrequency Ablation Catheter Design on Lesion Formation and Complications: In Vitro Comparison of 6 Different Devices

被引:60
作者
Guerra, Jose M. [1 ]
Jorge, Esther [1 ]
Raga, Silvia [1 ]
Galvez-Monton, Carolina [1 ]
Alonso-Martin, Concepcion [1 ]
Rodriguez-Font, Enrique [1 ]
Cinca, Juan [1 ]
Vinolas, Xavier [1 ]
机构
[1] Univ Autonoma Barcelona, Inst Recerca HSCSP IIB St Pau, Dept Cardiol, Hosp Santa Creu & St Pau, E-08193 Barcelona, Spain
关键词
atrial fibrillation; catheter ablation; irrigated catheter; lesion size; radiofrequency ablation; LARGE TIP; ELECTRODE; SIZE; IMPACT;
D O I
10.1111/jce.12175
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In Vitro Comparison of Open-Irrigated Catheters IntroductionOpen-irrigated radiofrequency ablation catheters with slight differences in tip architecture are widely used, although limited comparative data are available. The purpose of this study was to compare the lesion size and potential complications produced by commercially available open-irrigated catheters in an in vitro porcine heart model. Methods and ResultsSix catheters were tested (Biosense Webster Thermocool, Boston Scientific Open irrigated, St. Jude CoolPath, St. Jude CoolPath Duo, Biosense Webster Thermocool SF, St. Jude Cool Flex) at 20 and 35 W power-control, under 2 different blood flows (0.1 and 0.5 m/s) and at 2 target durations (30 and 60 seconds). A total of 601 lesions were made in 26 in vitro preparations. The tip temperature profile showed significant differences between the catheters (P < 0.001) with the Thermocool SF registering the lowest. Only the surface diameter and the depth at maximum diameter of the lesion were influenced by the design of the ablation electrode. The lesion volume did not show significant differences between catheters for any power, application duration or blood flow condition. Char and pops occurred more often at 35 W with only slight differences between the catheters. ConclusionsTip design of the 6 different irrigated catheters does not affect the lesion total volume, although a slight difference in lesion geometry in terms of surface diameter and depth at maximum diameter is present. The catheters show a slight different in vitro safety profile
引用
收藏
页码:1157 / 1162
页数:6
相关论文
共 16 条
  • [1] Catheter tip orientation affects radiofrequency ablation lesion size in the canine left ventricle
    Chugh, SS
    Chan, RC
    Johnson, SB
    Packer, DL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (03): : 413 - 420
  • [2] Comparison of irrigated electrode designs for radiofrequency ablation of myocardium
    Demazumder, D
    Mirotznik, MS
    Schwartzman, D
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (04) : 391 - 400
  • [3] Biophysics of radiofrequency ablation using an irrigated electrode
    Demazumder, D
    Mirotznik, MS
    Schwartzman, D
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (04) : 377 - 389
  • [4] Radiofrequency catheter ablation: Different cooled and noncooled electrode systems induce specific lesion geometries and adverse effect profiles
    Dorwarth, U
    Fiek, M
    Remp, T
    Reithmann, C
    Dugas, M
    Steinbeck, G
    Hoffmann, E
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07): : 1438 - 1445
  • [5] Safety Profiles and Lesion Size of Different Radiofrequency Ablation Technologies: A Comparison of Large Tip, Open and Closed Irrigation Catheters
    Everett, Thomas H.
    Lee, Ken W.
    Wilson, Emily E.
    Guerra, Jose M.
    Varosy, Paul D.
    Olgin, Jeffrey E.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) : 325 - 335
  • [6] Haines D E., 2011, Catheter ablation of cardiac arrhythmias, V2nd, P2
  • [7] Ikeda A, 2011, HEART RHYTHM, V8, pS27
  • [8] Drug therapy - Radio-frequency ablation as treatment for cardiac arrhythmias
    Morady, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (07) : 534 - 544
  • [9] Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling
    Nakagawa, H
    Wittkampf, FHM
    Yamanashi, WS
    Pitha, JV
    Imai, S
    Campbell, B
    Arruda, M
    Lazzara, R
    Jackman, WM
    [J]. CIRCULATION, 1998, 98 (05) : 458 - 465
  • [10] COMPARISON OF IN-VIVO TISSUE TEMPERATURE PROFILE AND LESION GEOMETRY FOR RADIOFREQUENCY ABLATION WITH A SALINE-IRRIGATED ELECTRODE VERSUS TEMPERATURE CONTROL IN A CANINE THIGH MUSCLE PREPARATION
    NAKAGAWA, H
    YAMANASHI, WS
    PITHA, JV
    ARRUDA, M
    WANG, XZ
    OHTOMO, K
    BECKMAN, KJ
    MCCLELLAND, JH
    LAZZARA, R
    JACKMAN, WM
    [J]. CIRCULATION, 1995, 91 (08) : 2264 - 2273