Clinical application of three-dimensional echocardiography: past, present and future

被引:13
作者
Kleijn, S. A. [1 ,2 ]
Kamp, O. [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[2] ICIN, Utrecht, Netherlands
来源
NETHERLANDS HEART JOURNAL | 2009年 / 17卷 / 01期
关键词
cardiovascular imaging; real-time three-dimensional echocardiography; clinical application; history; development; RIGHT-VENTRICULAR VOLUME; CONGENITAL HEART-DISEASE; MITRAL-VALVE-STENOSIS; DOBUTAMINE STRESS ECHOCARDIOGRAPHY; TIME 3D ECHOCARDIOGRAPHY; REAL-TIME; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; MECHANICAL DYSSYNCHRONY; EJECTION FRACTION; TRANSTHORACIC ECHOCARDIOGRAPHY;
D O I
10.1007/BF03086210
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Significant advances in three-dimensional echocardiography have made this modality a powerful diagnostic tool in the cardiology clinic. It can provide accurate and reliable measurements of chamber size and function, including the quantification of left ventricular mechanical dyssynchrony to guide patient selection for cardiac resynchronisation therapy. Furthermore, three-dimensional echocardiography offers novel views and comprehensive anatomic definition of valvular and congenital abnormalities, improving diagnosis and preoperative planning. In addition, it is extremely useful in monitoring the effectiveness of surgical or percutaneous transcatheter interventions. As its efficacy for more and more clinical applications is demonstrated, it is clear that three-dimensional echocardiography has become part of the routine clinical diagnostic armamentarium. In this article, we describe the development of three-dimensional echocardiography over the last decades, review the scientific evidence for its current clinical use and discuss potential future applications. (Neth Heart J 2009;17:18-24.)
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
[11]   Real-time three-dimensional echocardiography - A novel technique to quantify global left ventricular mechanical dyssynchrony [J].
Kapetanakis, S ;
Kearney, MT ;
Siva, A ;
Gall, N ;
Cooklin, M ;
Monaghan, MJ .
CIRCULATION, 2005, 112 (07) :992-1000
[12]   Three-dimensional echocardiography of the aortic valve: Feasibility, clinical potential, and limitations [J].
Kasprzak, JD ;
Salustri, A ;
Roelandt, JRTC ;
Ten Cate, FJ .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (02) :127-138
[13]   Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI [J].
Kjaergaard, Jesper ;
Petersen, Claus Leth ;
Kjaer, Andreas ;
Schaadt, Bente Krogsgaard ;
Oh, Jae K. ;
Hassager, Christian .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (06) :430-438
[14]   Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular Systolic function [J].
Krenning, Boudewijn J. ;
Kirschbaum, Sharon W. ;
Soliman, Osama I. I. ;
Nemes, Attila ;
van Geuns, Robert-Jan ;
Vletter, Wim B. ;
Veltman, Caroline E. ;
ten Cate, Folkert J. ;
Roelandt, Jos R. T. C. ;
Geleijnse, Marcel L. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (09) :1485-1489
[15]   High-resolution transthoracic real-time three-dimensional echocardiography -: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging [J].
Kuhl, HP ;
Schreckenberg, M ;
Rulands, D ;
Katoh, M ;
Schäfer, W ;
Schummers, G ;
Bücker, A ;
Hanrath, P ;
Franke, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2083-2090
[16]   Three-dimensional echocardiographic determination of left ventricular volumes and function by multiplane transesophageal transducer:: Dynamic in vitro validation and in vivo comparison with angiography and thermodilution [J].
Kühl, HP ;
Franke, A ;
Janssens, U ;
Merx, M ;
Graf, J ;
Krebs, W ;
Reul, H ;
Rau, G ;
Hoffmann, R ;
Klues, HG ;
Hanrath, P .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (12) :1113-1124
[17]   Additional value of three-dimensional transesophageal echocardiography for patients with mitral valve stenosis undergoing balloon valvuloplasty [J].
Langerveld, J ;
Valocik, G ;
Plokker, HWT ;
Ernst, SMPG ;
Mannaerts, HFJ ;
Kelder, JC ;
Kamp, O ;
Jaarsma, W .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (08) :841-849
[18]   System for quantitative three-dimensional echocardiography of the left ventricle based on a magnetic-field position and orientation sensing system [J].
Legget, ME ;
Leotta, DF ;
Bolson, EL ;
McDonald, JA ;
Martin, RW ;
Li, XN ;
Otto, CM ;
Sheehan, FH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (04) :494-504
[19]   3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION OF THE MITRAL-VALVE, WITH IMPLICATIONS FOR THE DIAGNOSIS OF MITRAL-VALVE PROLAPSE [J].
LEVINE, RA ;
HANDSCHUMACHER, MD ;
SANFILIPPO, AJ ;
HAGEGE, AA ;
HARRIGAN, P ;
MARSHALL, JE ;
WEYMAN, AE .
CIRCULATION, 1989, 80 (03) :589-598
[20]   Design of a new surgical approach for ventricular remodeling to relieve ischemic mitral regurgitation - Insights from 3-dimensional echocardiography [J].
Liel-Cohen, N ;
Guerrero, JL ;
Otsuji, Y ;
Handschumacher, MD ;
Rudski, LG ;
Hunziker, PR ;
Tanabe, H ;
Scherrer-Crosbie, M ;
Sullivan, S ;
Levine, RA .
CIRCULATION, 2000, 101 (23) :2756-2763