Stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet/inductively coupled plasma mass spectrometry for analysis of thyroxine in urine samples

被引:30
作者
Fan, Wenying [1 ]
Mao, Xiangju [1 ]
He, Man [1 ]
Chen, Beibei [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Key Lab Analyt Chem Biol & Med, Minist Educ, Wuhan 430072, Peoples R China
关键词
Stir bar sorptive extraction; PEG/OH-PDMS/gamma-MPTS coating; HPLC-UV/ICP-MS; Amphoteric thyroxines analysis; Human urine; BIOLOGICAL SAMPLES; GAS-CHROMATOGRAPHY; IODINE SPECIATION; THYROID-HORMONES; HPLC; IODOTHYRONINES; ENANTIOMERS; WATER;
D O I
10.1016/j.chroma.2013.10.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, polyethyleneglycol (PEG)/hydroxyl polydimethylsiloxane (OH-PDMS)/gamma-mercaptopropyl trimethoxysilane (gamma-MPTS) coated stir bar was prepared by sol-gel process and its extraction performance for the extraction of amphoteric thyroxines (3,3',5,5'-tetraiodothyronin, T-4; 3,3',5-triiodothyronine, T-3; reversed-3,3',5-triiodothyronine, rT(3)) and their metabolite (3,5-diiodothyronine, T-2) was studied. The preparation reproducibility of PEG/OH-PDMS/gamma-MPTS coated stir bar was investigated, and the relative standard deviations (RSDs) in the same batch and among different batches were 3.3-14.3% (n = 5) and 7.7-16.6% (n =3), respectively. The prepared PEG/OH-PDMS/gamma-MPTS coated stir bar could be reused for more than 20 times. Based on this fact, a novel method of stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV) and HPLC-inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of target thyroxines in human urine samples was developed. The influencing factors of SBSE, such as sample pH, extraction time, stirring rate, salt effect, desorption solution and desorption time, were studied in detail, and the analytical performance of the proposed method was evaluated under the optimized conditions. The enrichment factors (EFs) of the developed method for four target thyroxines were in the range of 14.9-70.4 (theoretical enrichment factor was 100). The RSDs were ranging from 4.0% to 13.8% for SBSE-HPLC-UV (c= 25 mu g/L, n = 6) and from 3.7% to 6.1% for SBSE-HPLC-ICP-MS (c = 0.5 mu g/L, n = 5). The linear range obtained by SBSE-HPLC-UV was 2-500 mu g/L for 12 and 5-500 mu g/L for rT(3), T-3 and T-4, with correlation coefficients (r) ranging from 0.9957 to 0.9998, respectively, while the linear range obtained by SBSE-HPLC-ICP-MS was 0.05-500 mu g/L for T-2 and rT(3), 0.10-200 mu g/L for T-3 and 0.05-200 mu g/L for 14 with r ranging from 0.9979 to 0.9998, respectively. The limits of detection (LODs) for the target thyroxines were 0.60-2.20 mu g/L for SBSE-HPLC-UV and 0.0071-0.0355 mu g/L SBSE-HPLC-ICP-MS, respectively. The developed method was applied for the determination of target thyroxines in urine samples, and the recovery for the spiking samples obtained by SBSE-HPLC-UV was in the range of 81.6-137.6% for human urine, while the recovery for the spiking urine samples obtained by SBSE-HPLC-ICP-MS were in the range of 72.0-121.5%. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
[21]   HLB/PDMS-Coated Stir Bar Sorptive Extraction of Microcystins in Shellfish Followed by High-Performance Liquid Chromatography and Mass Spectrometry Analysis [J].
Cui, Yiwei ;
Li, Shiyan ;
Yang, Xianqing ;
Wang, Yang ;
Dai, Zhiyuan ;
Shen, Qing .
FOOD ANALYTICAL METHODS, 2018, 11 (06) :1748-1756
[22]   HLB/PDMS-Coated Stir Bar Sorptive Extraction of Microcystins in Shellfish Followed by High-Performance Liquid Chromatography and Mass Spectrometry Analysis [J].
Yiwei Cui ;
Shiyan Li ;
Xianqing Yang ;
Yang Wang ;
Zhiyuan Dai ;
Qing Shen .
Food Analytical Methods, 2018, 11 :1748-1756
[23]   Determination of fluoxetine in plasma by gas chromatography-mass spectrometry using stir bar sorptive extraction [J].
Fernandes, Christian ;
Van Hoeck, Els ;
Sandra, Pat ;
Lancas, Fernando M. .
ANALYTICA CHIMICA ACTA, 2008, 614 (02) :201-207
[24]   A Method for Methylmercury and Inorganic Mercury in Biological Samples Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry [J].
Narukawa, Tomohiro ;
Iwai, Takahiro ;
Chiba, Koichi ;
Feldmann, Joerg .
ANALYTICAL SCIENCES, 2018, 34 (11) :1329-1334
[25]   Membrane protected C18 coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detection for the determination of non-steroidal anti-inflammatory drugs in water samples [J].
Mao, Xiangju ;
He, Man ;
Chen, Beibei ;
Hu, Bin .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1472 :27-34
[26]   Triazine covalent organic polymer coated stir bar sorptive extraction coupled with high performance liquid chromatography for the analysis of trace phthalate esters in mineral water and liquor samples [J].
Wang, Zhuo ;
He, Man ;
Chen, Beibei ;
Hu, Bin .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1660
[27]   Metsulfuron-methyl Molecularly Imprinted Stir Bar Sorptive Extraction Coupled with High Performance Liquid Chromatography for Trace Sulfonylurea Herbicides Analysis in Complex Samples [J].
XU ZhigangDU ZhuoLIAN HaixianHU Yuling and LI Gongke School of Chemistry and Chemical EngineeringSun Yatsen UniversityGuangzhou PRChina .
Chemical Research in Chinese Universities, 2012, 28 (04) :594-599
[28]   Validation of a method for the determination of tributyltin in seawater by stir bar sorptive extraction-liquid chromatography tandem mass spectrometry [J].
Camino-Sanchez, F. J. ;
Zafra-Gomez, A. ;
Oliver-Rodriguez, B. ;
Ruiz-Naranjo, I. ;
Ruiz-Garcia, J. ;
Vilchez, J. L. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1263 :14-20
[29]   Metsulfuron-methyl Molecularly Imprinted Stir Bar Sorptive Extraction Coupled with High Performance Liquid Chromatography for Trace Sulfonylurea Herbicides Analysis in Complex Samples [J].
Xu Zhi-gang ;
Du Zhuo ;
Lian Hai-xian ;
Hu Yu-ling ;
Li Gong-ke .
CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (04) :594-599
[30]   Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry [J].
Jia, Xiaoyu ;
Han, Yi ;
Liu, Xinli ;
Duan, Taicheng ;
Chen, Hangting .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (01) :88-92