Refill Port Identification of Intrathecal Drug Delivery System Devices With a Raised Fill Port

被引:4
|
作者
Maino, Paolo [1 ]
van Kuijk, Sander M. J. [2 ]
Koetsier, Eva [1 ]
机构
[1] Reg Hosp Lugano, Neuroctr Southern Switzerland, Pain Management Ctr, Lugano, Switzerland
[2] Maastricht Univ, Med Ctr, Clin Epidemiol & Med Technol Assessment, Maastricht, Netherlands
关键词
intrathecal drug delivery; intrathecal pumps; chronic pain; spasticity; CONFERENCE PACC RECOMMENDATIONS; CLONIDINE OVERDOSE; MANAGEMENT; PREVENTION; THERAPY;
D O I
10.1111/papr.12759
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives The aim of this study was to assess the accuracy of the manual identification of the reservoir fill port (RFP) for refill of intrathecal drug delivery systems (IDDSs) with a raised RFP on the pump surface (raised-RFP-IDDSs), and compare this to previously reported data of patients with IDDSs with a recessed RFP (recessed-RFP-IDDSs). Methods Nineteen patients underwent 2 IDDS refills for the treatment of noncancer pain or spasticity. The primary endpoint of this prospective observational study was the deviation between the needle insertion point and the RFP center, quantified by fluoroscopic visualization. A distance surpassing that between the center and the margin of the RFP of 4 mm was considered a clinically relevant deviation. The results were compared with previously reported data of a patient cohort with recessed-RFP-IDDSs, and the differences were tested using Student's t-test. Results The mean deviation from the RFP center was 4.9 mm (standard deviation = 3.7). The RFP identification accuracy deviated more than the clinically relevant difference in 17 out of 35 instances (48.6%). The number of attempts and median procedural time was significantly correlated to the needle deviation. The mean deviations in the raised-RFP-IDDS cohort were consistently lower compared to the recessed-RFP-IDDS cohort (first refill procedure 4.0 vs. 8.5, P < 0.001; second procedure 5.9 vs. 8.1, P = 0.074). Conclusion The results of this study suggest that the manual localization of the RFP for raised-RFP-IDDSs is moderately accurate, and more accurate if compared to previously published accuracy of the template-guided technique for recessed-RFP-IDDSs.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 48 条
  • [21] Post Dural Puncture Headache Following Intrathecal Drug Delivery System Placement
    Neuman, Stephanie A.
    Eldrige, Jason S.
    Qu, Wenchun
    Freeman, Eric D.
    Hoelzer, Bryan C.
    PAIN PHYSICIAN, 2013, 16 (02) : 101 - 107
  • [22] Intrathecal Drug Delivery System (IDDS) for Cancer Pain Management: A Review and Updates
    Upadhyay, Surjya Prasad
    Mallick, Piyush N.
    AMERICAN JOURNAL OF HOSPICE & PALLIATIVE MEDICINE, 2012, 29 (05) : 388 - 398
  • [23] Management of a Cancer Patient with an Intrathecal Drug Delivery System and an Acute Brain Abscess
    Walega, David R.
    Korn, Marc
    JOURNAL OF PALLIATIVE MEDICINE, 2018, 21 (05) : 727 - 729
  • [24] Advancing Safety in Intrathecal Analgesia A Novel Web-Based Pharmacologic Requisition Platform and Data Repository for Intrathecal Drug Delivery Devices
    Sobey, Christopher M.
    Greene, Chad R.
    Ford, Lindsay J.
    Walters, Jenna L.
    Huntoon, Marc A.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2017, 42 (04) : 483 - 487
  • [25] Hickman catheter and implantable port devices for the delivery of chemotherapy: a phase II randomised controlled trial and economic evaluation
    Wu, Olivia
    Boyd, Kathleen
    Paul, Jim
    McCartney, Elaine
    Ritchie, Moira
    Mellon, D.
    Kelly, Linda
    Dixon-Hughes, Judith
    Moss, Jon
    BRITISH JOURNAL OF CANCER, 2016, 114 (09) : 979 - 985
  • [26] Infectious Complications Related to Intrathecal Drug Delivery System and Spinal Cord Stimulator System Implantations at a Comprehensive Cancer Pain Center
    Engle, Mitchell P.
    Vinh, Baominh P.
    Harun, Nusrat
    Koyyalagunta, Dhanalaksmi
    PAIN PHYSICIAN, 2013, 16 (03) : 251 - 257
  • [27] Massive Clonidine Overdose During Refill of an Implanted Drug Delivery Device for Intrathecal Analgesia: A Review of Inadvertent Soft-Tissue Injection During Implantable Drug Delivery Device Refills and Its Management
    Johnson, Marlene L.
    Visser, Eric J.
    Goucke, C. Roger
    PAIN MEDICINE, 2011, 12 (07) : 1032 - 1040
  • [28] Novel Use of Intrathecal Baclofen Drug Delivery System for Periodic Focal Dystonia in a Teenager
    Bahl, Anuj
    Tripathi, Claire
    McMullan, John
    Goddard, John
    NEUROMODULATION, 2013, 16 (03): : 273 - 275
  • [29] Loss of effectiveness with an implanted drug delivery system for intrathecal pain therapy due to corrosion
    Reining, Marco
    Kretzschmar, Michael
    PAIN PRACTICE, 2023, 23 (04) : 459 - 462
  • [30] Endophthalmitis in Eyes Treated with the Port Delivery System with Ranibizumab Summary of Cases during Clinical Trial Development
    Eichenbaum, David A.
    Freeman, William R.
    Chang, Margaret A.
    Brooks, Logan
    Chaudhry, Nauman
    Dadgostar, Hajir
    Mccannel, Colin A.
    Michels, Mark
    Mittra, Robert A.
    Wolfe, Jeremy D.
    Beindl, Victoria C.
    Jaycock, Philip
    Bobbala, Ashwini
    Gune, Shamika
    Spicer, Galin
    Callaway, Natalia
    OPHTHALMOLOGY RETINA, 2025, 9 (02): : 127 - 143