Refill Port Identification of Intrathecal Drug Delivery System Devices With a Raised Fill Port

被引:4
|
作者
Maino, Paolo [1 ]
van Kuijk, Sander M. J. [2 ]
Koetsier, Eva [1 ]
机构
[1] Reg Hosp Lugano, Neuroctr Southern Switzerland, Pain Management Ctr, Lugano, Switzerland
[2] Maastricht Univ, Med Ctr, Clin Epidemiol & Med Technol Assessment, Maastricht, Netherlands
关键词
intrathecal drug delivery; intrathecal pumps; chronic pain; spasticity; CONFERENCE PACC RECOMMENDATIONS; CLONIDINE OVERDOSE; MANAGEMENT; PREVENTION; THERAPY;
D O I
10.1111/papr.12759
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives The aim of this study was to assess the accuracy of the manual identification of the reservoir fill port (RFP) for refill of intrathecal drug delivery systems (IDDSs) with a raised RFP on the pump surface (raised-RFP-IDDSs), and compare this to previously reported data of patients with IDDSs with a recessed RFP (recessed-RFP-IDDSs). Methods Nineteen patients underwent 2 IDDS refills for the treatment of noncancer pain or spasticity. The primary endpoint of this prospective observational study was the deviation between the needle insertion point and the RFP center, quantified by fluoroscopic visualization. A distance surpassing that between the center and the margin of the RFP of 4 mm was considered a clinically relevant deviation. The results were compared with previously reported data of a patient cohort with recessed-RFP-IDDSs, and the differences were tested using Student's t-test. Results The mean deviation from the RFP center was 4.9 mm (standard deviation = 3.7). The RFP identification accuracy deviated more than the clinically relevant difference in 17 out of 35 instances (48.6%). The number of attempts and median procedural time was significantly correlated to the needle deviation. The mean deviations in the raised-RFP-IDDS cohort were consistently lower compared to the recessed-RFP-IDDS cohort (first refill procedure 4.0 vs. 8.5, P < 0.001; second procedure 5.9 vs. 8.1, P = 0.074). Conclusion The results of this study suggest that the manual localization of the RFP for raised-RFP-IDDSs is moderately accurate, and more accurate if compared to previously published accuracy of the template-guided technique for recessed-RFP-IDDSs.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 48 条
  • [11] Bleeding Complications in Patients Undergoing Intrathecal Drug Delivery System Implantation
    Warner, Nafisseh S.
    Bendel, Markus A.
    Warner, Matthew A.
    Strand, Jacob J.
    Gazelka, Halena M.
    Hoelzer, Bryan C.
    Mauck, William D.
    Lamer, Tim J.
    Kor, Daryl J.
    Moeschler, Susan M.
    PAIN MEDICINE, 2017, 18 (12) : 2422 - 2427
  • [12] Training for the Intraspinal Drug Delivery System Reservoir Refill Procedure Highly Variable: A Nationwide Survey of Health Care Professionals
    McGlothlen, Gail L.
    Rodriguez, Lori
    NEUROMODULATION, 2017, 20 (07): : 727 - 732
  • [13] Severe Hypertension Following Accidental Clonidine Overdose During the Refilling of an Implanted Intrathecal Drug Delivery System
    Perruchoud, Christophe
    Bovy, Michele
    Durrer, Anne
    Rosato, Marilu
    Rutschmann, Blaise
    Mustaki, Jean-Pierre
    Buchser, Eric
    NEUROMODULATION, 2012, 15 (01): : 31 - 34
  • [14] Use of Eptifibatide as a Bridge Antiplatelet Agent for Intrathecal Drug Delivery System Placement
    Sisk, Joseph
    Palma, Michael
    Cooper, Christopher
    Eltahawy, Ehab
    Atallah, Joseph
    PAIN PHYSICIAN, 2012, 15 (06) : 479 - 483
  • [15] In-vitro characterization of ranibizumab release from the Port Delivery System
    Yohe, Stefan
    Maass, Katie F.
    Horvath, Judit
    Rea, Jennifer
    Barteselli, Giulio
    Ranade, Shrirang V.
    JOURNAL OF CONTROLLED RELEASE, 2022, 345 : 101 - 107
  • [16] Multicenter Experience with Nusinersen Application via an Intrathecal Port and Catheter System in Spinal Muscular Atrophy
    Flotats-Bastardas, Marina
    Hahn, Andreas
    Schwartz, Oliver
    Linsler, Steffan
    Meyer, Sascha
    Kolodziej, Malgorzata
    Koehler, Cornelia
    NEUROPEDIATRICS, 2020, 51 (06) : 401 - 406
  • [17] Therapeutic Potential of the Ranibizumab Port Delivery System in the Treatment of AMD: Evidence to Date
    Chen, Eric R.
    Kaiser, Peter K.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1349 - 1355
  • [18] The Effect of Measured Radiotherapy Dose on Intrathecal Drug Delivery System Function
    Odell, Daniel W.
    Albrechtsen, Richard D.
    Sindt, Jill E.
    Gole, Ryan
    Brown, Spencer
    Parsons, Matthew W.
    Paxton, Adam B.
    Sarkar, Vikren
    Lloyd, Shane
    Brogan, Shane E.
    Tao, Randa
    NEUROMODULATION, 2021, 24 (07): : 1204 - 1208
  • [19] Intrathecal Drug Delivery System: A Pain Management Option for Refractory Cancer-Related Pain
    Wanderman, Robalee L.
    Hagedorn, Jonathan M.
    PAIN MEDICINE, 2021, 22 (02) : 523 - 526
  • [20] Bolus Intrathecal Injection of Ziconotide (Prialt®) to Evaluate the Option of Continuous Administration via an Implanted Intrathecal Drug Delivery (ITDD) System: A Pilot Study
    Mohammed, Salma I.
    Eldabe, Sam
    Simpson, Karen H.
    Brookes, Morag
    Madzinga, Grace
    Gulve, Ashish
    Baranidharan, Ganesan
    Radford, Helen
    Crowther, Tracey
    Buchser, Eric
    Perruchoud, Christophe
    Batterham, Alan Mark
    NEUROMODULATION, 2013, 16 (06): : 576 - 582