Test results of the ALICE-HMPID detector commissioning

被引:0
作者
Volpe, G. [1 ]
机构
[1] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
来源
ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS | 2008年 / 4卷
关键词
LHC; HMPID; Detector Control System;
D O I
10.1142/9789812819093_0025
中图分类号
O59 [应用物理学];
学科分类号
摘要
The ALICE High Momentum Particle Identification Detector (HMPID) consists of seven identical proximity focusing RICH counters. It covers in total 11 m(2), exploiting large area CsI photocathodes for Cherenkov light imaging. The detector is installed in the ALICE solenoid, ready for the data acquisition. By means of the Detector Control System, the Front-end (FEE) and the Readout (R/O) electronics, the MWPC high voltages, the cooling and the gas system have been tested. The HMPID module gas pressure, temperature, current and voltage trends have been monitored and archived in the ORACLE database. In this paper a comprehensive review on the test results is presented.