A Pooled Analysis of Diagnostic Value of 99mTc-Ubiquicidin (UBI) Scintigraphy in Detection of an Infectious Process

被引:39
作者
Ostovar, Afshin [1 ]
Assadi, Mahsan [1 ]
Vahdat, Katayoun [1 ]
Nabipour, Iraj [1 ]
Javadi, Hamid [2 ]
Eftekhari, Mohammad [3 ]
Assadi, Majid [4 ]
机构
[1] Bushehr Univ Med Sci, Persian Gulf Trop Med Res Ctr, Dept Infect Dis, Bushehr 3631, Iran
[2] Golestan Univ Med Sci GUOMS, GRCGH, Gorgan, Iran
[3] Univ Tehran Med Sci, Res Ctr Nucl Med, Tehran, Iran
[4] Bushehr Univ Med Sci, Persian Gulf Nucl Med Res Ctr, Bushehr 3631, Iran
关键词
Tc-99m-UBI scan; antimicrobial peptides; infection; ANTIMICROBIAL PEPTIDE; CLINICAL-EVALUATION; BACTERIAL-INFECTION; UBIQUICIDIN; 29-41; IMAGING AGENT; LOCALIZATION;
D O I
10.1097/RLU.0b013e3182867d56
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although the data are promising from limited studies with technetium-99m ubiquicidin (Tc-99m-UBI) scintigraphy in detection of infection in humans, these studies have had a limited sample size. This study was conducted to provide a systematic review and meta-analysis of the reported diagnostic accuracy of Tc-99m-UBI scintigraphy in detection of an infectious process. Materials and Methods: The PubMed/MEDLINE, Web of Science, EMBASE, and Google Scholar literature databases were systematically searched to find the relevant human studies on Tc-99m-UBI scintigraphy. For each eligible study, the true-positive, false-positive, true-negative, and false-negative findings at Tc-99m-UBI scintigraphy were recorded, and the overall statistical parameters were acquired. Result: Ten studies carried out from 2004 to 2010 were included in the analysis. The pooled data sensitivity was 94.5% and with a 95% confidence interval of 91.2%-96.8%. The pooled specificity was still as high as about 92.7%. The range of reported specificity was from 80% to 100%. The overall accuracy was 93.7% (95% CI: 91.2%-95.7%). Conclusion: The study demonstrated that Tc-99m-UBI scintigraphy can be used to identify an infectious process with admirable accuracy in early views; however, further investigations are recommended.
引用
收藏
页码:413 / 416
页数:4
相关论文
共 30 条
[1]  
Akhtar MS, 2005, J NUCL MED, V46, P567
[2]   An imaging analysis of 99mTc-UBI (29-41) uptake in S-aureus infected thighs of rabbits on ciprofloxacin treatment [J].
Akhtar, Muhammad Saeed ;
Khan, Muhammad Ejaz ;
Khan, Bashar ;
Irfanullah, Javaid ;
Afzal, Muhammad Shahzad ;
Khan, Muhammad Aleem ;
Nadeem, Muhammad Afzal ;
Jehangir, Mustansar ;
Imran, Muhammad Babar .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) :1056-1064
[3]  
[Anonymous], CRIT APPR SKILLS PRO
[4]   Clinical trial of specific imaging of infections [J].
Arteaga de Murphy, Consuelo ;
Gemmel, Filip ;
Balter, Jenny .
NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (08) :726-733
[5]   99mTc-labeled ubiquicidin scintigraphy A promising method in hip prosthesis infection diagnosis [J].
Aryana, K. ;
Hootkani, A. ;
Sadeghi, R. ;
Davoudi, Y. ;
Naderinasab, M. ;
Erfani, M. ;
Ayati, N. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2012, 51 (04) :133-139
[6]   Diagnostic value of 99mTc-ubiquicidin scintigraphy for osteomyelitis and comparisons with 99mTc-methylene diphosphonate scintigraphy and magnetic resonance imaging [J].
Assadi, Majid ;
Vahdat, Katayoun ;
Nabipour, Iraj ;
Sehhat, Mohammad Reza ;
Hadavand, Fahimeh ;
Javadi, Hamid ;
Tavakoli, Alireza ;
Saberifard, Jamshid ;
Kalantarhormozi, Mohammad Reza ;
Zakani, Alireza ;
Eftekhari, Mohammad .
NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (08) :716-723
[7]  
Britton KE, 1997, EUR J NUCL MED, V24, P553
[8]  
CALAME W, 1993, EUR J NUCL MED, V20, P490
[9]  
Dams ETM, 2000, J NUCL MED, V41, P622
[10]  
Dillmann-Arroyo C, 2011, Acta Ortop Mex, V25, P27