Advanced Comparison of Phased Array and X-rays in the Inspection of Metallic Welding

被引:3
|
作者
Alonso, Jose [1 ]
Pavon, Santiago [2 ]
Vidal, Juan [2 ]
Delgado, Manuel [3 ]
机构
[1] Univ Cadiz, Ctr Andaluz Super Estudios Marinos, Dept Appl Phys, Cadiz 11510, Spain
[2] Univ Cadiz, Ctr Andaluz Super Estudios Marinos, Dept Ship Bldg, Cadiz 11510, Spain
[3] Navantia San Fernando, Dept Ship Bldg, Qual Inspect, Carretera Carraca S-N, Cadiz 11100, Spain
关键词
phased array; X-rays; metallic welding; nondestructive inspection;
D O I
10.3390/ma15207108
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The most common nondestructive weld inspection technique is X-rays and, since a few years ago, the ultrasound-based phased array. Their comparison has been done from the top view of both, with the result that the phased array is much more efficient in discovering flaws. From the last studies of the authors, a welding flaw can be three-dimensionally reconstructed from the sectorial phased array information. The same methodology is applied to compare quantitatively X-rays and phased array on 15 metal inert/active (MIG/MAG) welding specimens covering pores, slag intrusion and cracks. The results can be summarized in the correlation of the top views and in the correlation profiles between the X-ray top-view and the reconstructed top-view at the depths from phased array in the weld. The maximum correlation is the depth when the flaw in the X-ray looks like that in the phased array records at some depth, leading to an effective quantitative comparison of X-rays and phased array.
引用
收藏
页数:14
相关论文
共 15 条
  • [11] Irradiation-Induced Changes in the Immunogenicity of Lung Cancer Cell Lines: Based on Comparison of X-rays and Carbon Ions
    Ran, Juntao
    Wang, Jiangtao
    Dai, Ziying
    Miao, Yandong
    Gan, Jian
    Zhao, Chengpeng
    Guan, Quanlin
    FRONTIERS IN PUBLIC HEALTH, 2021, 9
  • [12] A COMPARISON OF ACTIVE-REGION TEMPERATURES AND EMISSION MEASURES OBSERVED IN SOFT X-RAYS AND MICROWAVES AND IMPLICATIONS FOR CORONAL HEATING
    KLIMCHUK, JA
    GARY, DE
    ASTROPHYSICAL JOURNAL, 1995, 448 (02) : 925 - 937
  • [13] COMPARISON OF EFFECTS OF IRON AND CALCIUM CHELATORS ON THE RESPONSE OF L5178Y SUBLINES TO X-RAYS AND H2O2
    KRUSZEWSKI, M
    GREEN, MHL
    LOWE, JE
    SZUMIEL, I
    MUTATION RESEARCH-FUNDAMENTAL AND MOLECULAR MECHANISMS OF MUTAGENESIS, 1995, 326 (02) : 155 - 163
  • [14] Comparison of shunt and series/shunt nMOS single-pole double-throw switches for X-band phased array T/R modules
    Kuo, Wei-Min Lance
    Comeau, Jonathan P.
    Andrews, Joel M.
    Cressler, John D.
    Mitchell, Mark A.
    2007 TOPICAL MEETING ON SILICON MONOLITHIC INTEGRATED CIRCUITS IN RF SYSTEMS, DIGEST OF PAPERS, 2007, : 249 - +
  • [15] COMPARISON OF INITIAL YIELDS OF DNA-TO-PROTEIN CROSS-LINKS AND SINGLE-STRAND BREAKS INDUCED IN CULTURED HUMAN-CELLS BY FAR- AND NEAR-ULTRAVIOLET LIGHT, BLUE-LIGHT AND X-RAYS
    PEAK, JG
    PEAK, MJ
    MUTATION RESEARCH, 1991, 246 (01): : 187 - 191