Advanced Comparison of Phased Array and X-rays in the Inspection of Metallic Welding

被引:3
|
作者
Alonso, Jose [1 ]
Pavon, Santiago [2 ]
Vidal, Juan [2 ]
Delgado, Manuel [3 ]
机构
[1] Univ Cadiz, Ctr Andaluz Super Estudios Marinos, Dept Appl Phys, Cadiz 11510, Spain
[2] Univ Cadiz, Ctr Andaluz Super Estudios Marinos, Dept Ship Bldg, Cadiz 11510, Spain
[3] Navantia San Fernando, Dept Ship Bldg, Qual Inspect, Carretera Carraca S-N, Cadiz 11100, Spain
关键词
phased array; X-rays; metallic welding; nondestructive inspection;
D O I
10.3390/ma15207108
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The most common nondestructive weld inspection technique is X-rays and, since a few years ago, the ultrasound-based phased array. Their comparison has been done from the top view of both, with the result that the phased array is much more efficient in discovering flaws. From the last studies of the authors, a welding flaw can be three-dimensionally reconstructed from the sectorial phased array information. The same methodology is applied to compare quantitatively X-rays and phased array on 15 metal inert/active (MIG/MAG) welding specimens covering pores, slag intrusion and cracks. The results can be summarized in the correlation of the top views and in the correlation profiles between the X-ray top-view and the reconstructed top-view at the depths from phased array in the weld. The maximum correlation is the depth when the flaw in the X-ray looks like that in the phased array records at some depth, leading to an effective quantitative comparison of X-rays and phased array.
引用
收藏
页数:14
相关论文
共 15 条
  • [1] A New Insight on Phased Array Ultrasound Inspection in MIG/MAG Welding
    Alonso, Jose
    Pavon, Santiago
    Vidal, Juan
    Perdigones, Jose
    Carpena, Isaac
    MATERIALS, 2022, 15 (08)
  • [2] Positive identification by X-rays bone trabeculae comparison
    Quatrehomme, Gerald
    Biglia, Elodie
    Padovani, Bernard
    du Jardin, Philippe
    Alunni, Veronique
    FORENSIC SCIENCE INTERNATIONAL, 2014, 245 : E11 - E14
  • [3] CMOS X-rays detector array based on scintillating light guides
    Rocha, JG
    Ramos, NF
    Lanceros-Mendez, S
    Wolffenbuttel, RF
    Correia, JH
    SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) : 119 - 123
  • [4] A comparison of classical histology to anatomy revealed by hard X-rays
    Richter, Claus-Peter
    Tan, Xiaodong
    Young, Hunter
    Stock, Stuart
    Robinson, Alan
    Byskosh, Orest
    Zheng, Jing
    Soriano, Carmen
    Xiao, Xianghui
    Whitlon, Donna
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [5] Comparison Between X-rays Absorption and Emission Spectroscopy Measurements on a Ceramic Envelop Lamp
    BrunoLAFITTE
    MichelAUBES
    GeorgesZISSIS
    Plasma Science and Technology, 2007, (06) : 732 - 735
  • [6] Comparison between x-rays absorption and emission spectroscopy measurements on a ceramic envelop lamp
    Lafitte, Bruno
    Aubes, Michel
    Zissis, Georges
    PLASMA SCIENCE & TECHNOLOGY, 2007, 9 (06) : 732 - 735
  • [7] Comparison of the laser-induced plasma of different metal targets as X-rays sources in vacuum
    Bhatti, K. A.
    Ahmed, R.
    Khan, M. I.
    Khan, Jehan Zaib Ali
    Ali, A.
    Siddique, G.
    Latif, A.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2018, 173 (11-12): : 921 - 928
  • [8] Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays
    O'Brien, Michelle
    Bueermann, Ludwig
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2009, 114 (06) : 321 - 331
  • [9] Out-of-field dose studies with an anthropomorphic phantom: Comparison of X-rays and particle therapy treatments
    La Tessa, Chiara
    Berger, Thomas
    Kaderka, Robert
    Schardt, Dieter
    Koerner, Christine
    Ramm, Ulla
    Licher, Joerg
    Matsufuji, Nakahiro
    Dahlgren, Christina Vallhagen
    Lomax, Tony
    Reitz, Guenther
    Durante, Marco
    RADIOTHERAPY AND ONCOLOGY, 2012, 105 (01) : 133 - 138
  • [10] Comparison of Different De-noising Techniques for Removal of Poison Noise from Cervical X-Rays Images
    Asim, Muhammad Adeel
    Akram, Muhammad Usman
    Salam, Anum Abdul
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON COMMUNICATION, COMPUTING AND DIGITAL SYSTEMS (C-CODE), 2017, : 281 - 286