Effect of carbon addition on microstructure and mechanical properties of a wrought Co-Cr-Mo implant alloy

被引:67
作者
Lee, SH [1 ]
Takahashi, E
Nomura, N
Chiba, A
机构
[1] Iwate Univ, Ctr Reg Collaborat Res & Educ, Morioka, Iwate 0208551, Japan
[2] Iwate Univ, Fac Engn, Dept Welf Engn, Morioka, Iwate 0208551, Japan
关键词
cobalt chromium molybdenum alloy; microstructure; mechanical properties; biomaterial; carbon; wrought;
D O I
10.2320/matertrans.47.287
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The wrought Co-Cr-Mo alloys with C contents of 0.02, 0.09 and 0.18% (mass%) were fabricated by hot-forging process to Study the influence of carbon contents on the microstructures and mechanical properties. The microstructures of Co-29Cr-6Mo-0.02C and Co-29Cr-6Mo-0.09C consist of equiaxed uniform grains which contain stacking faults. twins and epsilon martensite hands. No carbide found at inter- and intragranular region. Co-29Cr-Wo-0.18C consists of irregular grain sizes and carbide found at inter- and intra-granular region. The carbide in Co-29Cr-6Mo-0.18C was identified as M23C6 type carbide from the XRD pattern analysis. It is found that the amount of stacking fault and epsilon martensite are strongly dependent upon the C content. The density of stacking faults and epsilon martensites observed in Co-29Cr-6Mo-0.09C decrease as compared with those observed in Co-29Cr-6Mo-0.02C. Moreover. the volume fraction of the gamma phase slightly increased with C content. Within an extent of C addition that no carbide precipitation occurs, the carbon addition reduces the amounts of crystal defects such as stacking faults and twins. and epsilon martensites. In addition, tensile strength slightly increases with C content and ductility reaches a maximum at C content of 0.09%. though 0.2% proof strength shows no noticeable differences.
引用
收藏
页码:287 / 290
页数:4
相关论文
共 15 条
[1]  
[Anonymous], ACTA METALL
[2]   Mechanical properties of forged low Ni and C-containing Co-Cr-Mo biomedical implant alloy [J].
Chiba, A ;
Kumagai, K ;
Takeda, H ;
Nomura, N .
PRICM 5: THE FIFTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-5, 2005, 475-479 :2317-2321
[3]   SOLUTION TREATMENT BEHAVIOR OF CO-CR-MO ALLOY [J].
CLEMOW, AJT ;
DANIELL, BL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (02) :265-279
[4]   STACKING-FAULTS AND FCC (GAMMA)-]HCP (EPSILON) TRANSFORMATION IN 18-8-TYPE STAINLESS-STEEL [J].
FUJITA, H ;
UEDA, S .
ACTA METALLURGICA, 1972, 20 (05) :759-+
[5]   Wear properties of Co-Cr-Mo-N plasma-melted surgical implant alloys [J].
Hsu, HC ;
Lian, SS .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 138 (1-3) :231-235
[6]   Electrochemical corrosion studies on Co-Cr-Mo implant alloy in biological solutions [J].
Hsu, RWW ;
Yang, CC ;
Huang, CA ;
Chen, YS .
MATERIALS CHEMISTRY AND PHYSICS, 2005, 93 (2-3) :531-538
[7]   STATIC MECHANICAL-PROPERTIES OF CAST AND SINTER-ANNEALED COBALT-CHROMIUM SURGICAL IMPLANTS [J].
KILNER, T ;
LAANEMAE, WM ;
PILLIAR, R ;
WEATHERLY, GC ;
MACEWEN, SR .
JOURNAL OF MATERIALS SCIENCE, 1986, 21 (04) :1349-1356
[8]   MARTENSITE PHASES IN 304 STAINLESS STEEL [J].
MANGONON, PL ;
THOMAS, G .
METALLURGICAL TRANSACTIONS, 1970, 1 (06) :1577-+
[9]   Effect of alloy preheating on the mechanical properties of As-cast Co-Cr-Mo-C alloys [J].
Montero-Ocampo, C ;
Talavera, M ;
Lopez, H .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1999, 30 (03) :611-620
[10]   GENERAL MECHANISM OF MARTENSITIC NUCLEATION .1. GENERAL CONCEPTS AND FCC-]HCP TRANSFORMATION [J].
OLSON, GB ;
COHEN, M .
METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1976, 7 (12) :1897-1904