Polydopamine@electrochemically reduced graphene oxide-modified electrode for electrochemical detection of free-chlorine

被引:92
作者
Kumar, Deivasigamani Ranjith [1 ]
Kesavan, Srinivasan [1 ]
Thi Toan Nguyen [1 ]
Hwang, Jinho [1 ]
Lamiel, Charmaine [1 ]
Shim, Jae-Jin [1 ]
机构
[1] Yeungnam Univ, Sch Chem Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
基金
新加坡国家研究基金会;
关键词
Electrochemically reduced graphene oxide; Polydopamine; Free chlorine; Amperometry; Swimming pool water; INSPIRED POLYDOPAMINE; OXYGEN REDUCTION; THIN-FILMS; DOPAMINE; SENSOR; WATER; SUPERCAPACITORS; MONOCHLORAMINE; NANOCOMPOSITES; HYPOCHLORITE;
D O I
10.1016/j.snb.2016.09.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the electropolymerization of dopamine on an electrochemically reduced graphene oxide (ERGO) surface that was utilized successfully for the electrocatalytic detection of free chlorine (free-Cl). ERGO was fabricated on a glassy carbon (GC) electrode by the reduction of graphene oxide (GO) using cyclic voltammetry (CV). Subsequently, the electrode (ERGO/GC) surface was electropolymerized using dopamine for 30 cycles and a polydopamine-modified electrode (PDA@ERGO/GC) was obtained. The PDA@ERGO/GC-modified electrode was characterized by field emission scanning electron microscopy, X-ray photoelectron spectroscopy, electrochemical impedance spectroscopy, and CV. The surface coverage concentration (tau) of the PDA@ERGO/GC electrode was 1.70 x 10(-1) mol cm(-2). The presence of quinone functional groups on the electrode surface offers excellent electrocatalytic ability for the determination of free-Cl. The calculated kinetic parameters of the fabricated electrode confirmed its facile performance towards the determination of free-Cl with a rate constant (ks) and charge transfer coefficient (a) of 3.38 s(-1) and 0.75, respectively. Under the optimal conditions, the reduction current of free-Cl is proportional to its concentration range, 9.9-215.2 mu M, with a correlation coefficient of 0.998 and a sensitivity and detection limit (LOD) of 0.0071 mu A mu M-1 and 44 nM, respectively. Furthermore, PDA@ERGO/GC was used for the real sample determination of free-C1 from swimming pool water with satisfactory recoveries obtained in the range of 102.4% to 103.0%. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:818 / 828
页数:11
相关论文
共 59 条
[1]   HOMOGENEOUS VS HETEROGENEOUS ELECTRON-TRANSFER IN ELECTROCHEMICAL REACTIONS - APPLICATION TO THE ELECTROHYDROGENATION OF ANTHRACENE AND RELATED REACTIONS [J].
AMATORE, C ;
GAREIL, M ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 147 (1-2) :1-38
[2]  
AMATORE C, 1978, J ELECTROANAL CHEM, V86, P227, DOI 10.1016/0368-1874(78)87021-X
[3]   Poly-dopamine films: Voltammetric sensor for pH monitoring [J].
Amiri, Mandana ;
Amali, Elaheh ;
Nematollahzadeh, Ali ;
Salehniya, Haneie .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 :53-58
[4]   Poly-dopamine thin film for voltammetric sensing of atenolol [J].
Amiri, Mandana ;
Amali, Elaheh ;
Nematollahzadeh, Ali .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :551-557
[5]  
[Anonymous], 1999, STANDARD METHODS EXA
[6]   Oxygen reduction reaction by electrochemically reduced graphene oxide [J].
Bikkarolla, Santosh Kumar ;
Cumpson, Peter ;
Joseph, Paul ;
Papakonstantinou, Pagona .
FARADAY DISCUSSIONS, 2014, 173 :415-428
[7]   Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application [J].
Chen, Liuyun ;
Tang, Yanhong ;
Wang, Ke ;
Liu, Chengbin ;
Luo, Shenglian .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (02) :133-137
[8]   Noncovalent functionalization of graphene with end-functional polymers [J].
Choi, Eun-Young ;
Han, Tae Hee ;
Hong, Jihyun ;
Kim, Ji Eun ;
Lee, Sun Hwa ;
Kim, Hyun Wook ;
Kim, Sang Ouk .
JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (10) :1907-1912
[9]   DIRECT OBSERVATION OF EPINEPHRINE AND NOREPINEPHRINE COSECRETION FROM INDIVIDUAL ADRENAL-MEDULLARY CHROMAFFIN CELLS [J].
CIOLKOWSKI, EL ;
COOPER, BR ;
JANKOWSKI, JA ;
JORGENSON, JW ;
WIGHTMAN, RM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (08) :2815-2821
[10]   DISPROPORTIONATION DURING ELECTROOXIDATION OF CATECHOLAMINES AT CARBON-FIBER MICROELECTRODES [J].
CIOLKOWSKI, EL ;
MANESS, KM ;
CAHILL, PS ;
WIGHTMAN, RM ;
EVANS, DH ;
FOSSET, B ;
AMATORE, C .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3611-3617